
stiebel eltron electrical components, German stiebel eltron models, stiebel eltron prices
stiebel eltron electrical components are resistive elements with three terminals, whose resistance can be adjusted according to a specific variation pattern. A potentiometer typically consists of a resistive element and a movable wiper. When the wiper moves along the resistive element, a resistance value or voltage proportional to the displacement is obtained at the output terminal. Potentiometers can be used as three-terminal components or as two-terminal components. The latter can be regarded as a variable resistor; since its function in a circuit is to obtain an output voltage that has a certain relationship with the input voltage (applied voltage), it is called a potentiometer. Potentiometer
- SKU
- _P004835566
- Category
- Electrical and Electronic Components
- Brand
- stiebel eltron
- Tags
- Connectors / Cable / Germany stiebel eltron / Switch / Relay / Controller
stiebel eltron electrical component parameters
1. Stable voltage refers to the stable voltage value generated across the zener diode when it passes the rated current. This value varies slightly with operating current and temperature. Due to differences in manufacturing processes, the zener voltage of the same model is not completely consistent. 2. Reverse leakage current refers to the current passing through the zener diode when it generates a stable voltage. Below this value, the zener diode can still regulate voltage, but the regulation effect will be poorer; above this value, as long as the rated power dissipation is not exceeded, it is permissible, and the voltage regulation performance will be better, but it will consume more electrical energy. 3. Dynamic resistance refers to the ratio of the change in voltage across the zener diode to the change in current. This ratio varies with the operating current; generally, the larger the operating current, the smaller the dynamic resistance. 4. Rated power dissipation is determined by the allowable temperature rise of the chip, and its value is the product of the stable voltage and the maximum allowable current. 5. Temperature coefficient: If the temperature of the zener diode changes, its stable voltage will also undergo slight changes. The relative change in voltage across the diode caused by a temperature change of 1℃ is the temperature coefficient (unit: %/℃). Generally speaking, zener values below 6V belong to Zener breakdown, where the temperature coefficient is negative; the temperature coefficient is positive. When the temperature rises, the depletion layer decreases. In the depletion layer, the valence electrons of atoms rise to higher energy levels, and a smaller electric field strength can excite valence electrons from the atoms to produce Zener breakdown, so its temperature coefficient is negative. Avalanche breakdown occurs when the depletion layer is wider and the electric field strength is lower. An increase in temperature increases the vibration amplitude of lattice atoms, hindering the movement of carriers. In this case, only by increasing the reverse voltage can avalanche breakdown occur, so the voltage temperature coefficient of avalanche breakdown is positive. For applications with high power supply requirements, two zener diodes with opposite temperature coefficients can be connected in series for compensation. Due to mutual compensation, the temperature coefficient is greatly reduced. 15. Reverse leakage current refers to the leakage current generated by the zener diode under the specified reverse voltage.
stiebel eltron electrical component functions
In DC circuits, a capacitor is equivalent to an open circuit. A capacitor is a component capable of storing electric charge and is one of the most commonly used electronic components. Starting with the structure of a capacitor: the simplest capacitor consists of two end plates and an insulating dielectric medium in between (including air). After being energized, the plates become charged, forming a voltage (potential difference). However, due to the insulating material in between, the entire capacitor is non-conductive. However, this situation holds under the premise that the critical voltage (breakdown voltage) of the capacitor is not exceeded. We know that any material is relatively insulating; when the voltage across a material increases to a certain level, the material can become conductive. We call this voltage the breakdown voltage. Capacitors are no exception; once a capacitor breaks down, it is no longer an insulator. However, at the secondary school level, such voltages are not seen in circuits, so they operate below the breakdown voltage and can be regarded as insulators. However, in AC circuits, because the direction of current changes over time according to a certain functional relationship, and the charging and discharging process of a capacitor takes time, a changing electric field is formed between the plates, and this electric field is also a function that changes with time. In fact, current passes through the capacitor in the form of an electric field.
stiebel eltron electrical component principles
When two different conductors or semiconductors A and B form a loop with their ends connected to each other, as long as the temperatures at the two junctions are different, with one end at temperature T (called the working end or hot end) and the other end at temperature T0 (called the free end or cold end), an electromotive force (EMF) will be generated in the loop. The direction and magnitude of this EMF are related to the materials of the conductors and the temperatures of the two junctions. This phenomenon is called the "thermoelectric effect." The loop formed by the two conductors is called a "thermocouple," the two conductors are called "thermoelectrodes," and the generated EMF is called "thermo-EMF." Thermo-EMF consists of two parts: the contact EMF of the two conductors and the temperature difference EMF of a single conductor. The magnitude of the thermo-EMF in a thermocouple loop depends only on the conductor materials composing the thermocouple and the temperatures of the two junctions, and is independent of the shape and dimensions of the thermocouple. Once the materials of the two thermocouple electrodes are fixed, the thermo-EMF is the functional difference between the temperatures t and t0 of the two junctions. This relationship is widely used in practical temperature measurement. Because the cold end t0 is constant, the thermo-EMF generated by the thermocouple changes only with the temperature of the hot end (measurement end), meaning a specific thermo-EMF corresponds to a specific temperature. We can achieve temperature measurement simply by measuring the thermo-EMF. The basic principle of thermocouple temperature measurement is that two homogeneous conductors of different compositions form a closed loop. When there is a temperature gradient between the two ends, current flows through the loop, and an EMF—thermo-EMF—exists between the two ends. This is the so-called Seebeck effect. The two homogeneous conductors of different compositions are the thermoelectrodes; the end with the higher temperature is the working end, and the end with the lower temperature is the free end. The free end is usually kept at a constant temperature. Based on the functional relationship between thermo-EMF and temperature, thermocouple graduation tables are created; these tables are obtained under the condition that the free end temperature is 1℃. Different thermocouples have different graduation tables. When a third metal material is introduced into the thermocouple loop, as long as the temperatures at the two junctions of this material are the same, the thermo-EMF generated by the thermocouple will remain unchanged, i.e., it is not affected by the introduction of the third metal into the loop. Therefore, during thermocouple temperature measurement, a measuring instrument can be connected. After measuring the thermo-EMF, the temperature of the measured medium can be determined. Thermocouple temperature measurement requires that the temperature of the cold end (the measurement end is the hot end; the end connected to the measurement circuit via lead wires is called the cold end) remains constant, so that the magnitude of the thermo-EMF has a certain proportional relationship with the measured temperature. If the (ambient) temperature of the cold end changes during measurement, it will seriously affect the accuracy of the measurement. Taking certain measures at the cold end to compensate for the effects caused by changes in cold end temperature is called thermocouple cold junction compensation. Special compensation wires are used to connect to the measuring instrument.
Thermocouple cold junction compensation calculation methods: (1) From millivolts to temperature: Measure the cold end temperature, convert it to the corresponding millivolt value, add it to the millivolt value of the thermocouple, and convert to temperature; (2) From temperature to millivolts: Measure the actual temperature and the cold end temperature, convert them separately to millivolt values, subtract to obtain the millivolt value, and thus determine the temperature.
Weidou Intelligent Technology specializes in selling German stiebel eltron connectors, stiebel eltron switches, stiebel eltron relays, stiebel eltron controllers, stiebel eltron plugs, stiebel eltron sensors, stiebel eltron resistors, stiebel eltron capacitors, stiebel eltron buses, stiebel eltron modules, stiebel eltron cables, stiebel eltron power supplies, stiebel eltron interfaces, stiebel eltron gateways, stiebel eltron circuit breakers. stiebel eltron original imports from Germany. Welcome customers to inquire and order.






