
Germany VALENTIN plug VALENTIN model VALENTIN price
VALENTIN plugs are conductive devices that bridge two conductors in a circuit, allowing current or signals to flow from one conductor to another. They are widely used in various electrical circuits to connect or disconnect current or signals. This connection may be temporary and convenient for plugging and unplugging at any time, or it may be a permanent node between electrical equipment or wires. Electronic connectors are devices that transmit electronic signals (analog or digital signals), providing a separable interface to connect two sub-electronic systems. They are components used to complete electrical connections between circuits or electronic
- SKU
- _P004500324
- Category
- phoenix connectors, telegartner plugs
- Brand
- VALENTIN
- Tags
- Connectors / Connector / Interface Module / Terminal Block / Bus Interface / Germany VALENTIN
VALENTIN plug structure
An electrical connector consists of a fixed-end electrical connector, i.e., the female contact (referred to as a socket), and a free-end electrical connector, i.e., the male contact (referred to as a plug). The socket is mounted on the powered component via its square (or round) flange (some are also welded), while the plug is generally connected to a cable, with the plug–socket connection achieved through a coupling nut. An electrical connector comprises three basic units: the housing, the insulator, and the contacts. 1) Housing: The housing of an electrical connector refers to the outer shell of the plug and socket, the coupling nut, and the rear accessories. The shell protects internal components such as the insulator and contacts (collectively referring to pins and sockets) from damage. Positioning keyways on the top ensure proper alignment between the plug and socket. The coupling nut is used for mating and unmating the plug and socket. Rear accessories protect the wire-to-contact termination points from damage and secure the cable. The housing also provides a certain degree of electromagnetic shielding. Housings are typically machined from aluminum alloy (via machining, cold extrusion, or die casting). Steel housings are mostly used for glass-sealed and high-temperature-resistant electrical connectors. 2) Insulator: Composed of pin-mounting insulators, socket-mounting insulators, interface seals, wire seals, etc. It holds pins and sockets in their designated positions and ensures electrical insulation between individual contacts and between contacts and the housing. Sealing measures are achieved by adding interface seals and wire seals to the insulator to improve the environmental resistance of the electrical connector. To withstand high temperatures, low temperatures, and flame retardancy requirements while ensuring stable and reliable geometric dimensions of components, insulators are mostly molded from thermosetting plastics. Interface seals and wire seals are formed by molding silicone rubber, among other methods. 3) Contacts: Contacts include male and female contacts, sometimes referred to as pins and sockets. Connection methods include soldering, crimping, press-fit, and wire-wrapping, used to achieve circuit connections. Pins and sockets are critical components of electrical connectors, directly affecting their reliability. Most pins and sockets are machined from elastic copper alloys with good conductivity, with silver or gold plating applied to the surface to achieve low contact resistance and corrosion resistance. Sockets generally include split-type sockets, wire-spring sockets, crown-spring sockets, and stamped sockets. Structural features include: environmental resistance, bayonet (quick) connection, multiple keyways (prevention of incorrect mating), crimped connection between contacts and wires (single-wire insertion/removal facilitates fault handling). The housing plus a shielding ring ensures 360° electromagnetic interference shielding capability.
VALENTIN plug classification
Industrial bus networks can be categorized into three types: 485 network, HART network, and FieldBus fieldbus network. 485 network: RS485/MODBUS is a popular industrial networking method, characterized by simple and convenient implementation, and there are many instruments supporting RS485. Instrument manufacturers have also turned to support RS485/MODBUS for the simple reason that RS485 conversion interfaces are not only inexpensive but also diverse. At least in the low-end market, RS485/MODBUS will remain the primary industrial networking method. HART network: HART is a transitional bus standard proposed by Emerson, mainly characterized by superimposing digital signals on a 4-20 mA current signal. However, this protocol is not truly open; one must join its foundation to obtain the protocol, which requires a certain fee. HART technology is mainly monopolized by several large foreign companies. In recent years, domestic companies have also been working on it, but they have not yet reached the level of foreign companies. Many smart instruments come with [HART round card] and support HART communication functions. However, from the domestic perspective, this functionality has not been truly utilized for device networking and monitoring; at most, handheld communicators are used for parameter setting. In the long run, due to reasons such as low HART communication speed and difficult networking, the application of HART instruments will show a downward trend. FieldBus Fieldbus network: Fieldbus is one of the hot technologies in the automation field today, hailed as the computer LAN of the automation field. Its emergence marks the beginning of a new era in automation control technology. Fieldbus is a digital, serial, multi-station communication network connecting field instruments with control devices in the control room. Its key hallmark is the ability to support bidirectional, multi-node, bus-style fully digital communication. Fieldbus technology has become a hotspot in the international development of automation and instrumentation. Its emergence has brought revolutionary changes to traditional control system structures, further advancing automatic control systems towards "intelligence, digitization, informatization, networking, and decentralization," forming a new type of networked communication fully distributed control system—Fieldbus Control System FCS (Fieldbus Control System). However, fieldbus has not yet formed a truly unified standard. Multiple standards such as ProfiBus, CANbus, and CC-Link coexist, each with its own niche. When unification will occur is uncertain. There are relatively few types of instruments supporting fieldbus, leaving little room for choice, with higher prices and smaller usage volumes.
VALENTIN plug safety parameters
1) Insulation Resistance: Insulation resistance refers to the resistance value exhibited due to leakage current generated within or on the surface of the insulating part of a connector when voltage is applied. It is mainly influenced by factors such as insulating material, temperature, humidity, and contamination. The insulation resistance values provided in connector catalogs are typically specified under standard atmospheric conditions; under certain environmental conditions, insulation resistance values may decrease to varying degrees. Additionally, pay attention to the test voltage value for insulation resistance. According to Insulation Resistance (MΩ) = Voltage Applied to the Insulator (V) / Leakage Current (μA), applying different voltages yields different results. In connector testing, the applied voltages generally have three levels: 10V, 100V, and 500V. 2) Rated Voltage: Dielectric strength is the critical voltage that the mutually insulated parts of a contact pair, or between insulated parts and ground, can withstand for a specified time without breakdown, exceeding the rated voltage. It is mainly influenced by contact pair spacing, creepage distance, geometry, insulator material, ambient temperature and humidity, and atmospheric pressure. 3) Mechanical Life: The mechanical life of a connector refers to its mating/unmating cycle life, typically specified as 500 to 1000 cycles. When this specified mechanical life is reached, indicators such as contact resistance, insulation resistance, and dielectric strength should not exceed specified limits. Strictly speaking, mechanical life is related to time; using 500 cycles over 10 years is obviously different from using 500 cycles over 1 years. First, select the number of contact pairs based on circuit requirements, while considering the connector's volume and total separation force. A higher number of contact pairs naturally results in larger volume and relatively greater total separation force. In cases with high reliability requirements where volume permits, two contact pairs can be connected in parallel to improve connection reliability. In connector plugs and sockets, pins (male contacts) and sockets (female contacts) are generally interchangeable in assembly. In actual use, selection can be made based on the live status at both ends of the plug and socket. For example, if the socket needs to remain live, choose a socket equipped with female contacts, because the live contacts are embedded in the insulator, making them less accessible to human touch and thus relatively safer. Mainly consider the electrical continuity of contact pairs during vibration, shock, and collision under specified frequency and acceleration conditions. Contact pairs may experience instantaneous open circuits under such dynamic stress. Specified instantaneous interruption times generally include 1μs, 10μs, 100μs, 1ms, and 10ms. Note how to judge instantaneous interruption faults in contact pairs. Currently, it is considered that a fault in a closed contact pair (contact) has occurred when the voltage drop across both ends exceeds 50% of the power source electromotive force. In other words, there are two criteria for judging instantaneous interruption: duration and voltage drop, both of which are indispensable. Connectors generally consist of plugs and sockets, where the plug is also called a free-end connector and the socket is also called a fixed connector. Circuit connection and disconnection are achieved through the mating and unmating of plugs and sockets, resulting in various connection methods for plugs and sockets. For circular connectors, the main connection methods are threaded, bayonet, and push-pull (ball-lock). Among these, threaded connection is the most common, offering advantages such as simple processing, low manufacturing cost, and wide applicability, but it has a slower connection speed and is unsuitable for frequent mating/unmating and quick connections. Bayonet connection has a faster connection speed due to the longer lead of its three bayonet slots, but it is more complex to manufacture and thus more expensive. Push-pull (ball-lock) connection is the fastest among the three methods; it does not require rotational motion, achieving connection, separation, and locking through linear motion only. As it belongs to the straight push-pull connection method, it is only suitable for connectors with low total separation force. It is generally more common in small-sized connectors.
Weidou Intelligent Technology professionally sells German VALENTIN connectors, VALENTIN connectors, VALENTIN interface modules, VALENTIN terminal blocks, VALENTIN bus interfaces, VALENTIN bus modules, VALENTIN communication modules, VALENTIN fieldbus, VALENTIN plug interfaces, VALENTIN communication interfaces, VALENTIN adapters, VALENTIN output modules, VALENTIN distributor converters, VALENTIN plug bus, VALENTIN expansion modules, VALENTIN original German imports. Welcome customers to inquire and order.






