
German DELTA METAL sensor DELTA METAL model DELTA METAL price
DELTA METAL sensors are devices or apparatuses that can sense pressure signals and convert them into usable output electrical signals according to a specific pattern. Pressure sensors typically consist of a pressure-sensitive element and a signal processing unit. Depending on the type of test pressure, pressure sensors can be classified into gauge pressure sensors, differential pressure sensors, and absolute pressure sensors. Pressure sensors are one of the most commonly used sensors in industrial practice, widely applied in various industrial automation environments, including water conservancy and hydropower, railway transportation, smart buildings, production automation, aerospace,
- SKU
- _P004479732
- Category
- balluff sensor turck sensor in stock
- Brand
- DELTA METAL
- Tags
- Photoelectric Sensor / German sensors / Inductive Sensor / Measurement Sensors / DELTA METAL sensor
DELTA METAL sensor classification
1) Contact type: The sensing part of a contact temperature sensor has good contact with the object being measured; it is also known as a thermometer. The thermometer reaches thermal equilibrium through conduction or convection, allowing its reading to directly indicate the temperature of the object being measured. Generally, the measurement accuracy is high. Within a certain temperature measurement range, thermometers can also measure the internal temperature distribution of an object. However, significant measurement errors may occur for moving objects, small targets, or objects with very small heat capacity. Commonly used thermometers include bimetallic thermometers, glass liquid thermometers, pressure thermometers, resistance thermometers, thermistors, and thermocouples. They are widely used in industrial, agricultural, and commercial sectors. People also frequently use these thermometers in daily life. With the widespread application of cryogenic technology in national defense engineering, space technology, metallurgy, electronics, food, medicine, petrochemicals, and research into superconducting technology, cryogenic thermometers for measuring temperatures below 120K have been developed, such as low-temperature gas thermometers, vapor pressure thermometers, acoustic thermometers, paramagnetic salt thermometers, quantum thermometers, low-temperature resistance thermometers, and low-temperature thermocouples. Cryogenic thermometers require sensing elements that are small in size, highly accurate, and have good reproducibility and stability. A carburized glass resistance thermometer, made by carburizing and sintering porous high-silica oxygen glass, is one type of sensing element for cryogenic thermometers and can be used to measure temperatures in the range of 1.6 to 300K. 2) Non-contact type: Its sensitive element does not come into contact with the object being measured; it is also known as a non-contact temperature measuring instrument. This instrument can be used to measure the surface temperature of moving objects, small targets, objects with small heat capacity, or objects with rapid temperature changes (transient), and can also be used to measure the temperature distribution of a temperature field. The most commonly used non-contact temperature measuring instruments are based on the basic laws of blackbody radiation and are called radiation thermometers. Radiation temperature measurement methods include the brightness method (see optical pyrometer), the radiation method (see radiation pyrometer), and the colorimetric method (see colorimetric thermometer). Various radiation temperature measurement methods can only measure the corresponding luminance temperature, radiation temperature, or colorimetric temperature. Only the temperature measured for a blackbody (an object that absorbs all radiation and reflects no light) is the true temperature. If the true temperature of an object is to be determined, correction for the material's surface emissivity must be performed. The surface emissivity of a material depends not only on temperature and wavelength but also on surface condition, coating, and microstructure, making precise measurement difficult. In automated production, radiation temperature measurement is often used to measure or control the surface temperature of certain objects, such as the rolling temperature of steel strips in metallurgy, roll temperature, forging temperature, and the temperature of various molten metals in smelting furnaces or crucibles. In these specific cases, measuring the surface emissivity of the object is quite difficult. For automatic measurement and control of solid surface temperature, an additional mirror can be used to form a blackbody cavity together with the measured surface. The influence of additional radiation can increase the effective radiation and effective emissivity of the measured surface. By using the effective emissivity to correct the measured temperature via the instrument, the true temperature of the measured surface can ultimately be obtained. The most typical additional mirror is a hemispherical mirror. Diffuse radiation from the measured surface near the center of the sphere is reflected back to the surface by the hemispherical mirror, forming additional radiation and thereby increasing the effective emissivity. In the formula, ε is the surface emissivity of the material, and ρ is the reflectivity of the mirror. For radiation measurement of the true temperature of gaseous and liquid media, a method involving inserting a heat-resistant material tube to a certain depth to form a blackbody cavity can be used. The effective emissivity of the cylindrical cavity after reaching thermal equilibrium with the medium is calculated. In automatic measurement and control, this value can be used to correct the measured cavity bottom temperature (i.e., the medium temperature) to obtain the true temperature of the medium.
DELTA METAL sensor usage precautions
1) Errors introduced by improper installation: For example, the installation position and insertion depth of the thermocouple cannot reflect the true temperature of the furnace chamber. In other words, the thermocouple should not be installed too close to the door or heating areas; the insertion depth should be at least 8 to 10 times the diameter of the protection tube; the gap between the thermocouple protection tube and the wall is not filled with insulating material, causing heat escape from the furnace or cold air intrusion. Therefore, the gap between the thermocouple protection tube and the furnace wall hole should be blocked with insulating materials such as refractory mud or asbestos rope to prevent convection of hot and cold air from affecting the accuracy of temperature measurement; the cold end of the thermocouple is too close to the furnace body, causing the temperature to exceed 100℃; the installation of the thermocouple should avoid strong magnetic and electric fields as much as possible, so the thermocouple and power cables should not be installed in the same conduit to avoid introducing interference and causing errors; the thermocouple cannot be installed in areas where the measured medium flows rarely. When using a thermocouple to measure the temperature of gas in a pipe, the thermocouple must be installed against the flow direction and have full contact with the gas. 2) Errors introduced by deteriorated insulation: If the thermocouple is insulated, excessive dirt or salt slag on the protection tube and pull plate causes poor insulation between the thermocouple poles and the furnace wall, which is more severe at high temperatures. This not only causes loss of thermoelectric potential but also introduces interference, with resulting errors sometimes reaching hundreds of degrees. 3) Errors introduced by thermal inertia: Due to the thermal inertia of the thermocouple, the instrument's indication lags behind changes in the measured temperature, an effect that is particularly prominent during rapid measurements. Therefore, thermocouples with thinner thermoelectrodes and smaller protection tube diameters should be used as much as possible. When the temperature measurement environment permits, the protection tube can even be removed. Due to measurement lag, the amplitude of temperature fluctuations detected by the thermocouple is smaller than the amplitude of furnace temperature fluctuations. The greater the measurement lag, the smaller the amplitude of thermocouple fluctuations, and the larger the difference from the actual furnace temperature. When using a thermocouple with a large time constant for temperature measurement or control, although the temperature displayed by the instrument fluctuates very little, the actual furnace temperature may fluctuate significantly. To measure temperature accurately, a thermocouple with a small time constant should be selected. The time constant is inversely proportional to the heat transfer coefficient and directly proportional to the diameter of the thermocouple's hot end, the density of the material, and the specific heat. To reduce the time constant, besides increasing the heat transfer coefficient, the most effective method is to minimize the size of the hot end. In use, materials with good thermal conductivity, thin-walled tubes, and small inner diameter protection sleeves are usually employed. In more precise temperature measurements, bare-wire thermocouples without protection sleeves are used, but thermocouples are prone to damage and should be calibrated and replaced in a timely manner. 4) Thermal resistance error: At high temperatures, if there is a layer of coal ash or dust attached to the protection tube, thermal resistance increases, hindering heat conduction. In this case, the temperature indication is lower than the true value of the measured temperature. Therefore, the exterior of the thermocouple protection tube should be kept clean to reduce errors.
DELTA METAL sensor industry applications
Temperature sensors are the earliest developed and most widely used type of sensor. The market share of temperature sensors greatly exceeds that of other sensors. Since the beginning of the 17 century, people have begun to use temperature for measurement. Supported by semiconductor technology, semiconductor thermocouple sensors, PN junction temperature sensors, and integrated temperature sensors were successively developed in this century. Two conductors of different materials, if connected together at a point and heated at this junction, will exhibit a potential difference at their unheated parts. The value of this potential difference is related to the temperature at the measurement point of the unheated part and the material of these two conductors. This phenomenon can occur over a wide temperature range. If this potential difference is measured precisely, and the ambient temperature of the unheated part is measured, the temperature of the heating point can be accurately determined. Because it requires two conductors of different materials, it is called a "thermocouple". Thermocouples made of different materials are used in different temperature ranges, and their sensitivities vary. Thermocouple sensors have their own advantages and disadvantages; their sensitivity is relatively low, they are easily affected by environmental interference signals, and they are also susceptible to the temperature drift of preamplifiers, making them unsuitable for measuring minute temperature changes. Since the sensitivity of thermocouple temperature sensors is unrelated to the thickness of the material.
Weidou Intelligent Technology specializes in selling German DELTA METAL sensors, DELTA METAL proximity sensors, DELTA METAL distance sensors, DELTA METAL vision sensors, DELTA METAL displacement sensors, DELTA METAL torque sensors, DELTA METAL speed sensors, DELTA METAL photoelectric sensors, DELTA METAL position sensors, DELTA METAL angle sensors, DELTA METAL tactile sensors, DELTA METAL temperature sensors, DELTA METAL pressure sensors, DELTA METAL flow sensors, DELTA METAL level sensors, DELTA METAL motion sensors, DELTA METAL process sensors, original imports from Germany. Welcome customers to inquire and order.






