
German Galltec sensors, Galltec models, Galltec prices
Galltec pressure sensors for liquid level measurement. Submersible hydrostatic level transmitters (level gauges) operate on the principle that the static pressure of the measured liquid is proportional to its height. They use advanced isolated diffused silicon sensitive elements or ceramic capacitive pressure sensitive sensors from abroad to convert static pressure into electrical signals. After temperature compensation and linear correction, these are converted into standard electrical signals (typically 4 to 20mA/15VDC). Galltec sensor classification: Load cells are classified by conversion method into photoelectric, hydraulic, electromagnetic force, capacitive, magnetic
- SKU
- _P004470535
- Category
- balluff sensor turck sensor in stock
- Brand
- Galltec
- Tags
- Proximity Sensor / Displacement Sensor / Photoelectric Sensor / Process Sensors / Germany Galltec
Galltec sensor classification
Load cells are classified by conversion method into 8 types, including photoelectric, hydraulic, electromagnetic force, capacitive, magnetic pole variation, vibratory, gyroscope, and resistance strain gauge types, with resistance strain gauge types being the most widely used. 1) Photoelectric type: Includes grating and code disk types. Grating sensors use Moiré fringes formed by gratings to convert angular displacement into photoelectric signals. There are two gratings: one fixed grating and one moving grating mounted on the dial shaft. The object being weighed on the load platform rotates the dial shaft via a force transmission lever system, driving the moving grating to rotate and causing the Moiré fringes to move. Using phototubes, conversion circuits, and display instruments, the number of moved Moiré fringes can be calculated to determine the angle of grating rotation, thereby determining and reading the mass of the object. Code disk sensors: A code disk (symbol plate) is a piece of transparent glass mounted on the dial shaft, featuring black and white codes arranged according to a specific encoding method. When the object on the load platform rotates the dial shaft via the force transmission lever, the code disk also rotates by a certain angle. Photocells receive light signals through the code disk and convert them into electrical signals, which are then digitally processed by the circuit, finally displaying the digital value representing the measured mass on the display. Photoelectric sensors were mainly used in electromechanical combination scales. 2) Hydraulic type: Under the action of the gravity P of the measured object, the pressure of the hydraulic oil increases, with the degree of increase proportional to P. By measuring the increase in pressure, the mass of the object can be determined. Hydraulic sensors have a simple and robust structure and a large measurement range, but accuracy generally does not exceed 1/100. 3) Capacitive type: It operates based on the proportional relationship between the oscillation frequency f of the capacitor oscillator circuit and the distance d between the plates. There are two plates, one fixed and one movable. When the object is loaded onto the load platform, the leaf spring deflects, changing the distance between the two plates and consequently changing the oscillation frequency of the circuit. By measuring the change in frequency, the mass of the object on the load platform can be determined. Capacitive sensors consume little power, have low cost, and offer an accuracy of 1/200 to 1/500.
Galltec sensor features
Resistors, inductors, and capacitors are the three major types of passive components in electronics. Capacitive sensors convert changes in the measured quantity into changes in capacitance; essentially, they are capacitors with variable parameters. Capacitive sensors offer the following advantages: high impedance, low power consumption, and require very low input energy. They can achieve large signal changes, resulting in high signal-to-noise ratios and system stability. They have fast dynamic response, with operating frequencies reaching several megahertz, allowing for non-b contact measurement; the measured object can be either a conductor or a semiconductor. They have a simple structure and strong adaptability, capable of operating in harsh environments such as high/low temperatures and strong radiation, leading to wide application. With the development of electronic technology and computer technology, disadvantages of capacitive sensors, such as susceptibility to interference and distributed capacitance, have been continuously overcome. Furthermore, capacitive grid displacement sensors and integrated capacitive sensors have been developed. Therefore, they are widely used in non-electrical quantity measurement and automatic detection, capable of measuring parameters such as pressure, displacement, speed, acceleration, A level, thickness, liquid level, humidity, vibration, and component content. Capacitive sensors have promising development prospects.
Galltec sensor installation precautions
1) Handle load cells with care, especially small-capacity sensors using aluminum alloy elastic bodies. Any impact or drop caused by vibration is likely to cause significant output errors.
2) When designing the loading device and during installation, ensure that the axis of the applied load coincides with the force-bearing axis of the load cell to minimize the effects of tilting and eccentric loads.
3) Regarding leveling: If using a load cell, adjust the mounting plane of its base with a spirit level until it is horizontal. If multiple sensors are used for simultaneous measurement, their base mounting surfaces should be kept as level as possible to ensure that the force borne by each sensor is basically consistent.
4) Determine the rated load of the sensor used based on the load cell capacity selection specified in its instructions.
5) To prevent chemical corrosion, apply Vaseline to the outer surface of the load cell during installation. Avoid direct sunlight and environments with drastic temperature changes.
6) Install bypassers made of copper braided wire at both ends of the load cell loading device.
7) Do not extend the cable yourself. If extension is absolutely necessary, solder the joints and apply moisture-proof sealant.
8) It is best to use baffles to cover the sensor around the load cell. This prevents debris from falling into the moving parts of the sensor, which could affect measurement accuracy.
9) Keep the sensor cables away from high-power power lines or areas with pulse waves. If avoidance is impossible, route the load cell cables separately through iron conduits and keep the connection distance as short as possible.
10) Determine the rated load of the sensor used based on the load cell capacity selection specified in its instructions. Although load cells have a certain overload capacity, avoid such situations during installation and use. Even short-term overloading may cause permanent damage to the sensor.
11) For high-precision applications, allow the load cell and instrument to warm up for 30 minutes before use.
Weidou Intelligent Technology specializes in selling German Galltec sensors, Galltec proximity sensors, Galltec distance sensors, Galltec vision sensors, Galltec displacement sensors, Galltec torque sensors, Galltec speed sensors, Galltec photoelectric sensors, Galltec position sensors, Galltec angle sensors, Galltec tactile sensors, Galltec temperature sensors, Galltec pressure sensors, Galltec flow sensors, Galltec level sensors, Galltec motion sensors, and Galltec process sensors. Original German imports. Welcome inquiries and orders from users.






