
German ETMAIC sensors ETMAIC models ETMAIC prices
ETMAIC sensors generally consist of 2 parts: the processing path and the processing elements. Their basic principle is based on the photoelectric effect, converting changes in the measured quantity into changes in optical signals, and then using photoelectric components to further convert non-electrical signals into electrical signals. The photoelectric effect refers to illuminating an object with light, which can be viewed as a stream of photons with specific energy bombarding the object. At this point, the photon energy is transferred to electrons, and the entire energy of one photon is absorbed by one electron at once. After receiving the energy from the photon, the state of the electron
- SKU
- _P004470506
- Category
- balluff sensor turck sensor in stock
- Brand
- ETMAIC
- Tags
- Proximity Sensor / Displacement Sensor / Photoelectric Sensor / Process Sensors / Germany ETMAIC
ETMAIC sensor classification
1) Contact type: The sensing element of a contact temperature sensor has good contact with the object being measured; it is also called a thermometer. The thermometer reaches thermal equilibrium through conduction or convection, so that its indication directly represents the temperature of the object being measured. Generally, the measurement accuracy is relatively high. Within a certain temperature measurement range, the thermometer can also measure the internal temperature distribution of an object. However, significant measurement errors occur for moving bodies, small targets, or objects with very small heat capacity. Commonly used thermometers include bimetallic thermometers, glass liquid-in-glass thermometers, pressure-filled thermometers, resistance thermometers, thermistors, and thermocouples. They are widely used in industrial, agricultural, commercial, and other sectors. These thermometers are also frequently used in daily life. With the extensive application of cryogenic technology in national defense engineering, space technology, metallurgy, electronics, food, medicine, petrochemicals, and research into superconductivity, cryogenic thermometers for measuring temperatures below 120K have been developed, such as cryogenic gas thermometers, vapor-pressure thermometers, acoustic thermometers, paramagnetic salt thermometers, quantum thermometers, cryogenic resistance thermometers, and cryogenic thermocouples. Cryogenic thermometers require sensing elements that are small in size, highly accurate, and offer good reproducibility and stability. A carburized glass resistance thermometer, made by carburizing and sintering porous high-silica glass, is one type of sensing element for cryogenic thermometers and can be used to measure temperatures in the range of 1.6 to 300K. 2) Non-contact type: Its sensing element does not come into contact with the object being measured; it is also called a non-contact temperature measuring instrument. This instrument can be used to measure the surface temperature of moving objects, small targets, objects with small heat capacity, or objects with rapid (transient) temperature changes, and can also be used to measure temperature field distributions. The most commonly used non-contact temperature measuring instruments are based on the fundamental laws of blackbody radiation and are called radiation thermometers. Radiation thermometry includes the brightness method (see optical pyrometer), the radiation method (see radiation pyrometer), and the colorimetric method (see colorimetric thermometer). Various radiation thermometry methods can only measure the corresponding brightness temperature, radiation temperature, or colorimetric temperature. Only the temperature measured for a blackbody (an object that absorbs all radiation and reflects no light) is the true temperature. To determine the true temperature of an object, correction for the material's surface emissivity is required. Material surface emissivity depends not only on temperature and wavelength but also on surface condition, coatings, and microstructure, making precise measurement difficult. In automated production, radiation thermometry is often used to measure or control the surface temperature of certain objects, such as the rolling temperature of steel strips, roll temperature, forging temperature, and the temperature of various molten metals in smelting furnaces or crucibles in metallurgy. In these specific cases, measuring the surface emissivity of the object is quite difficult. For automatic measurement and control of solid surface temperatures, an additional mirror can be used to form a blackbody cavity together with the measured surface. The influence of additional radiation can increase the effective radiation and effective emissivity of the measured surface. By using the effective emissivity to appropriately correct the measured temperature via the instrument, the true temperature of the measured surface can ultimately be obtained. The most typical additional mirror is a hemispherical mirror. Diffuse radiation from the measured surface near the center of the sphere is reflected back to the surface by the hemispherical mirror, forming additional radiation and thereby increasing the effective emissivity, where ε is the material surface emissivity and ρ is the reflectivity of the mirror. For radiation measurement of the true temperature of gaseous and liquid media, a method involving inserting a heat-resistant material tube to a certain depth to form a blackbody cavity can be used. The effective emissivity of the cylindrical cavity after reaching thermal equilibrium with the medium is calculated. In automatic measurement and control, this value can be used to correct the measured temperature at the bottom of the cavity (i.e., the medium temperature) to obtain the true temperature of the medium.
ETMAIC sensor usage precautions
1) Errors introduced by improper installation: For example, the installation position and insertion depth of a thermocouple may not reflect the true temperature of the furnace chamber. In other words, the thermocouple should not be installed too close to doors or heating elements, and the insertion depth should be at least 8 to 10 times the diameter of the protection tube. If the gap between the thermocouple protection tube and the wall is not filled with insulating material, heat may escape from the furnace or cold air may enter. Therefore, the gap between the thermocouple protection tube and the furnace wall hole should be blocked with insulating materials such as refractory clay or asbestos rope to prevent convection of hot and cold air from affecting the accuracy of temperature measurement. The cold junction of the thermocouple is too close to the furnace body, causing the temperature to exceed 100℃. Thermocouple installation should avoid strong magnetic and electric fields as much as possible, so thermocouples and power cables should not be installed in the same conduit to avoid introducing interference and causing errors. Thermocouples should not be installed in areas where the measured medium has little flow. When using a thermocouple to measure the temperature of gas in a pipe, the thermocouple must be installed against the flow direction and in full contact with the gas. 2) Errors introduced by deteriorated insulation: If the thermocouple insulation is compromised, excessive dirt or salt slag on the protection tube and pull plate can cause poor insulation between the thermocouple poles and the furnace wall. This is more severe at high temperatures, causing not only loss of thermoelectric potential but also introducing interference. The resulting error can sometimes reach hundreds of degrees. 3) Errors introduced by thermal inertia: Due to the thermal inertia of the thermocouple, the instrument's indication lags behind changes in the measured temperature. This effect is particularly prominent during rapid measurements. Therefore, thermocouples with thinner thermoelectrodes and smaller protection tube diameters should be used as much as possible. If the temperature measurement environment permits, the protection tube can even be removed. Due to measurement lag, the amplitude of temperature fluctuations detected by the thermocouple is smaller than the amplitude of furnace temperature fluctuations. The greater the measurement lag, the smaller the amplitude of the thermocouple fluctuation, and the larger the difference from the actual furnace temperature. When using a thermocouple with a large time constant for temperature measurement or control, although the temperature displayed by the instrument fluctuates very little, the actual furnace temperature fluctuation may be significant. To measure temperature accurately, a thermocouple with a small time constant should be selected. The time constant is inversely proportional to the heat transfer coefficient and directly proportional to the diameter of the thermocouple's hot junction, the density of the material, and the specific heat. To reduce the time constant, besides increasing the heat transfer coefficient, the most effective method is to minimize the size of the hot junction. In use, materials with good thermal conductivity, thin-walled tubes, and small inner diameter protection tubes are typically used. In more precise temperature measurements, bare-wire thermocouples without protection tubes are used, but thermocouples are prone to damage and should be calibrated and replaced in a timely manner. 4) Thermal resistance error: At high temperatures, if there is a layer of coal ash or dust on the protection tube, thermal resistance increases, hindering heat conduction. In this case, the temperature indication is lower than the true value of the measured temperature. Therefore, the exterior of the thermocouple protection tube should be kept clean to reduce errors.
ETMAIC sensor industry applications
Temperature sensors are the earliest developed and most widely used type of sensor. The market share of temperature sensors greatly exceeds that of other sensors. People began using temperature for measurement in the early 17 century. Supported by semiconductor technology, semiconductor thermocouple sensors, PN junction temperature sensors, and integrated temperature sensors were successively developed in this century. Two conductors of different materials, when connected together at a point and heated at that junction, will exhibit a potential difference at their unheated parts. The value of this potential difference is related to the temperature at the measurement point of the unheated part and the materials of the two conductors. This phenomenon can occur over a wide temperature range. If this potential difference is measured precisely and the ambient temperature of the unheated part is measured, the temperature of the heated point can be accurately determined. Because it requires two conductors of different materials, it is called a "thermocouple." Thermocouples made of different materials are suitable for different temperature ranges, and their sensitivities vary. Thermocouple sensors have their own advantages and disadvantages; their sensitivity is relatively low, they are easily affected by environmental interference signals, and they are also susceptible to the temperature drift of preamplifiers, making them unsuitable for measuring minute temperature changes. Since the sensitivity of thermocouple temperature sensors is unrelated to the thickness of the material.
Weidou Intelligent Technology professionally sells German ETMAIC sensors, ETMAIC proximity sensors, ETMAIC distance sensors, ETMAIC vision sensors, ETMAIC displacement sensors, ETMAIC torque sensors, ETMAIC speed sensors, ETMAIC photoelectric sensors, ETMAIC position sensors, ETMAIC angle sensors, ETMAIC tactile sensors, ETMAIC temperature sensors, ETMAIC pressure sensors, ETMAIC flow sensors, ETMAIC level sensors, ETMAIC motion sensors, ETMAIC process sensors. Original German imports. Welcome customers to inquire and order.






