Home/Products/ moog valve rexroth valve

German Buehler valve Buehler model Buehler price
Buehler valves are valves that reduce the inlet pressure to a required outlet pressure through regulation, and rely on the energy of the medium itself to automatically maintain stable outlet pressure. From the perspective of fluid mechanics, a pressure reducing valve is a throttling element with variable local resistance, i.e., by changing the throttling area, the flow velocity and kinetic energy of the fluid are changed, causing different pressure losses, thereby achieving pressure reduction. Then, through the regulation of the control and adjustment system, the fluctuation of the pressure after the valve is balanced with the spring force, keeping the pressure after the valve constant within a certain error range.
- SKU
- _P004467043
- Category
- moog valve rexroth valve
- Brand
- Buehler
- Tags
- Valves / Control Valve / Solenoid Valve / Safety Valve / Globe Valve / Buehler valve
Buehler valves are valves that reduce the inlet pressure to a required outlet pressure through regulation, and rely on the energy of the medium itself to automatically maintain stable outlet pressure. From the perspective of fluid mechanics, a pressure reducing valve is a throttling element with variable local resistance, i.e., by changing the throttling area, the flow velocity and kinetic energy of the fluid are changed, causing different pressure losses, thereby achieving pressure reduction. Then, through the regulation of the control and adjustment system, the fluctuation of the pressure after the valve is balanced with the spring force, keeping the pressure after the valve constant within a certain error range.
Buehler valve working principle
The pressure reducing valve reduces water pressure by the local resistance of the flow channel inside the valve to the water flow. The range of water pressure drop is automatically adjusted by the water pressure difference between the inlet and outlet on both sides of the diaphragm or piston connected to the valve disc. The fixed-ratio pressure reduction principle uses the water pressure ratio of the floating piston in the valve body for control; the pressure reduction ratio between the inlet and outlet ends is inversely proportional to the area ratio of the pistons on the inlet and outlet sides. This type of pressure reducing valve operates smoothly without vibration; there is no spring inside the valve body, so there is no concern about spring corrosion or metal fatigue failure; the sealing performance is good with no leakage, thus reducing both dynamic pressure (when water is flowing) and static pressure (when flow rate is 0); especially, it does not affect the water flow rate while reducing pressure. The pressure reducing valve regulates the flow rate of the medium by controlling the opening degree of the closing member in the valve body, reducing the pressure of the medium, and at the same time, adjusts the opening degree of the closing member by the action of the pressure after the valve, keeping the pressure after the valve within a certain range, and injecting cooling water into the valve body or after the valve to reduce the temperature of the medium; this type of valve is called a pressure reducing and desuperheating valve. Kuaiyiyou Automation Selection includes this valve. The characteristic of this valve is to maintain the outlet pressure and temperature values within a certain range when the inlet pressure changes continuously.
Buehler valve installation precautions
1) Before installing the valve, carefully verify whether the model and specifications of the valve used match the design; 2) Check against the valve model and factory instruction manual to determine if the valve can be applied under the required conditions; 3) When lifting the valve, the rope should be tied to the flange connection between the valve body and the valve cover, and do not tie it to the handwheel or valve stem to avoid damaging the valve stem and handwheel; 4) When installing the valve on a horizontal pipe, the valve stem should be vertically upward; downward installation of the valve stem is not allowed; 5) When installing the valve, do not use forced alignment connection methods such as pulling or dragging hard, to avoid damage caused by uneven force; 6) Open-stem gate valves should not be installed in underground damp places to avoid corrosion of the valve stem.
Buehler valve troubleshooting
In certain pressure reduction control circuits, the outlet pressure of the pressure reducing valve is used to control the control oil pressure of electro-hydraulic directional valves or externally controlled sequence valves, etc. When the electro-hydraulic directional valve or externally controlled sequence valve shifts or operates, the flow rate at the outlet of the pressure reducing valve becomes zero, but the pressure still needs to maintain the originally set pressure. In this case, since the outlet flow rate of the valve is zero, the flow rate through the pressure reduction port is only the pilot flow. Since the pilot flow is very small, generally within 2L/min, the main valve pressure reduction port is basically close to the fully closed position (extremely small opening), and the pilot flow flows out from the triangular groove or inclined cone surface. If the fit of the main valve spool is too loose or the wear is excessive, the leakage increases. According to the continuity theorem of flow, this part of the leakage must also flow from the damping hole of the main valve spool, i.e., the flow through the damping hole consists of two parts: pilot flow and leakage. Since the area of the damping hole and the oil pressure in the main valve spring chamber remain unchanged (the oil pressure in the spring chamber is determined by the pre-compression amount of the adjusted pressure regulating spring), to increase the flow through the damping hole, the oil pressure in the lower chamber of the main valve will inevitably rise. Therefore, after the outlet pressure of the pressure reducing valve is set, if the outlet flow rate is zero, the outlet pressure will rise due to the loose fit or excessive wear of the main valve spool.
Weidou Intelligent Technology professionally sells German Buehler valves, Buehler safety valves, Buehler globe valves, Buehler control valves, Buehler solenoid valves, Buehler ball valves, Buehler proportional valves, Buehler diaphragm valves, Buehler butterfly valves, Buehler hydraulic transmission valves, Buehler check valves, Buehler pressure reducing valves, Buehler relief valves, Buehler sequence valves, Buehler balance valves, Buehler throttle valves, Buehler directional valves, original German imports, welcome customers to inquire and order.