German Bucher valves Bucher models Bucher prices

German Bucher valves Bucher models Bucher prices

Bucher valves are electromagnetically controlled industrial devices. They are basic automation components for fluid control, classified as actuators, and are not limited to hydraulic or pneumatic applications. They are used in industrial control systems to adjust media direction, flow rate, speed, and other parameters. Solenoid valves can be combined with different circuits to achieve desired control, ensuring precision and flexibility. There are many types of solenoid valves, each serving different functions within a control system. The most common types include check valves, safety valves, directional control valves, and speed control valves. Bucher valves

SKU
_P004467042
Category
moog valve rexroth valve
Brand
Bucher
Tags
Valves / Control Valve / Solenoid Valve / Safety Valve / Globe Valve / Bucher valves

Bucher valves are electromagnetically controlled industrial devices. They are basic automation components for fluid control, classified as actuators, and are not limited to hydraulic or pneumatic applications. They are used in industrial control systems to adjust media direction, flow rate, speed, and other parameters. Solenoid valves can be combined with different circuits to achieve desired control, ensuring precision and flexibility. There are many types of solenoid valves, each serving different functions within a control system. The most common types include check valves, safety valves, directional control valves, and speed control valves.


Bucher valve operating principle


The solenoid valve contains a sealed chamber with ports opened at different positions, each connected to different oil lines. A piston is located in the center of the chamber, with two electromagnets on either side. When the coil on one side is energized, the valve body is attracted to that side. By controlling the movement of the valve body, different oil discharge ports are opened or closed, while the oil inlet port remains normally open. Hydraulic oil enters different discharge lines, and the oil pressure pushes the cylinder piston. The piston drives the piston rod, which in turn drives the mechanical device. Thus, mechanical motion is controlled by switching the current to the electromagnets on and off.


Bucher valve routine maintenance


1) Pay attention to the valve storage environment; it should be stored in a dry, ventilated indoor area, with both ends of the flow path blocked. 2) Valves should be inspected regularly, cleaned of dirt, and coated with anti-rust oil on their surfaces. 3) Valves that have been installed and put into service should undergo regular maintenance to ensure proper operation. 4) Inspect the valve sealing surface for wear and repair or replace it as necessary. 5) Check the trapezoidal threads of the valve stem and stem nut for wear, and check if the packing is outdated or failed, replacing them as necessary. 6) Test the sealing performance of the valve to ensure its integrity. 7) Valves in operation should be in good condition, with all bolts on flanges and supports present, threads undamaged, and no looseness. 8) If the handwheel is lost, it should be replaced promptly; do not use an adjustable wrench as a substitute. 9) The packing gland must not be tilted or lack pre-tightening clearance. 10) If the valve operates in a harsh environment prone to contamination by rain, snow, dust, or sand, a protective cover should be installed on the valve stem. 11) Scales on the valve should remain complete, accurate, and clear; check the valve lead seal and cap. 12) The insulation jacket should have no dents or cracks. 13) Avoid striking valves in operation or using them to support heavy loads.


Bucher valve classification


Solenoid valves are divided into three main categories based on their operating principle: 1) Direct-acting solenoid valve. Principle: When energized, the electromagnetic coil generates a force that lifts the closing member off the valve seat, opening the valve. When de-energized, the electromagnetic force disappears, and a spring presses the closing member against the valve seat, closing the valve. Features: It can operate normally under vacuum, negative pressure, and zero pressure conditions, but the nominal diameter generally does not exceed 25mm. 2) Step-by-step direct-acting solenoid valve. Principle: This combines direct-acting and pilot-operated principles. When there is no pressure difference between the inlet and outlet, energizing the valve causes the electromagnetic force to lift the pilot small valve and the main valve closing member sequentially, opening the valve. When the pressure difference between the inlet and outlet reaches the starting differential, energizing the valve causes the electromagnetic force to act on the pilot small valve. The pressure in the lower chamber of the main valve rises, while the pressure in the upper chamber drops, pushing the main valve open via the pressure difference. When de-energized, the pilot valve uses spring force or media pressure to push the closing member downward, closing the valve. Features: It can operate reliably at zero pressure difference, vacuum, or high pressure, but has higher power consumption and requires horizontal installation. 3) Pilot-operated solenoid valve. Principle: When energized, the electromagnetic force opens the pilot hole, causing the pressure in the upper chamber to drop rapidly. A pressure difference forms around the closing member (lower pressure above, higher pressure below), pushing the closing member upward and opening the valve. When de-energized, the spring force closes the pilot hole. Inlet pressure rapidly enters the chamber through the bypass hole, forming a pressure difference around the closing member (higher pressure above, lower pressure below), pushing the closing member downward to close the valve. Features: It has a higher upper limit for fluid pressure range and can be installed in any orientation (customization required), but must meet fluid pressure difference conditions.



Weidou Intelligent Technology specializes in selling German Bucher valves, Bucher safety valves, Bucher globe valves, Bucher control valves, Bucher solenoid valves, Bucher ball valves, Bucher proportional valves, Bucher diaphragm valves, Bucher butterfly valves, Bucher hydraulic transmission valves, Bucher check valves, Bucher pressure reducing valves, Bucher relief valves, Bucher sequence valves, Bucher balance valves, Bucher throttle valves, and Bucher directional valves. Original imports from Germany. Welcome inquiries and orders.