Weidou Intelligent Technology (Shanghai) Co., Ltd.
中文
WDUTECH industrial automation products and services
Categories and filters

Home/Products/ Electrical and Electronic Components

HUMMELAG electrical components, German HUMMELAG models, HUMMELAG prices

HUMMELAG electrical components, German HUMMELAG models, HUMMELAG prices

HUMMELAG electrical components are tools for accurately determining and measuring temperature, categorized into dial thermometers and digital thermometers. Depending on the temperature-sensing substance and measurement range, types include kerosene thermometers, alcohol thermometers, mercury thermometers, gas thermometers, resistance thermometers, thermocouple thermometers, radiation thermometers, optical pyrometers, and bimetallic thermometers. Digital thermometers accurately determine and measure temperature, displaying values numerically rather than via a pointer or mercury column; hence they are called digital thermometers or digital temperature gauges. HUMMELAG Electrical

SKU
_P004837266
Category
Electrical and Electronic Components
Tags
Connectors / Cable / Switch / Relay / Controller / Germany HUMMELAG
HUMMELAG electrical components are tools for accurately determining and measuring temperature, categorized into dial thermometers and digital thermometers. Depending on the temperature-sensing substance and measurement range, types include kerosene thermometers, alcohol thermometers, mercury thermometers, gas thermometers, resistance thermometers, thermocouple thermometers, radiation thermometers, optical pyrometers, and bimetallic thermometers. Digital thermometers accurately determine and measure temperature, displaying values numerically rather than via a pointer or mercury column; hence they are called digital thermometers or digital temperature gauges.


Use of HUMMELAG electrical components


1, apply moderate force when tightening terminal connections to prevent stripping the threads of bolts and nuts due to excessive force. Replace any stripped bolts and nuts immediately; do not continue operation with compromised fasteners. 2, when using a screwdriver to tighten or loosen screws, press firmly to ensure the tip seats securely in the screw head before turning, preventing slippage that could damage the screw and make future removal difficult, especially for common miniature circuit breakers in distribution boxes. 3, if bolts or nuts are difficult to remove, do not force them, as this may cause deformation and further complicate removal. Instead, tap gently or apply a penetrating oil or dilute hydrochloric acid, then attempt removal after a short wait. 4, do not use pliers to tighten or loosen bolts or nuts, as this may cause damage. When using an adjustable wrench, adjust the jaw opening correctly to prevent damaging or deforming the fastener, which would hinder future disassembly. 5, each terminal block allows connection of up to two wires of the same type and specification. 6, for terminal blocks prone to loosening or poor contact, wire ends must be crimped into a "U" shape before securing to the terminal block to increase contact area and prevent loosening. 7, when connecting wire lugs or terminals, do not insert non-copper washers or washers with poor conductivity between them. 8, when connecting wire ends, ensure contact surfaces are smooth and free of oxidation. When connecting cable lugs or copper busbars, clean the contact surfaces, apply conductive paste, and then tighten. 9, when connecting temporary wiring, fold single-strand flexible wire once before connecting to the lower terminal of the miniature circuit breaker; single-core solid wire must be connected to the lower terminal of the miniature circuit breaker in a "U" shape. 10, for high-voltage motor wiring, do not insert washers with poor conductivity (such as galvanized nuts, flat washers, or spring washers) between the motor leads and the connecting cables. 16, when wrapping cables or other equipment requiring insulation protection with insulating tape, overlap the layers significantly from one end to the other, ensuring at least one full back-and-forth pass.


HUMMELAG electrical component composition


Transformer components include the core assembly (core, windings, insulation, leads), transformer oil, tank and cooling system, voltage regulation device, protective devices (breather, pressure relief vent, gas relay, oil conservator, and temperature monitoring devices), and bushings. Detailed composition and functions: (1) The core is the main magnetic circuit part of the transformer. It is typically constructed by stacking hot-rolled or cold-rolled silicon steel sheets with high silicon content and an insulated surface coating. The core consists of core legs and yokes; the windings are mounted on the core legs, while the yokes complete the magnetic circuit. (2) The windings constitute the electrical circuit of the transformer, made of double-insulated flat wire or enamel-coated round wire. The basic principle of a transformer is electromagnetic induction. Taking a single-phase two-winding transformer as an example: when voltage is applied to the primary winding, current flows, generating an alternating magnetic flux in the core. This main flux induces electromotive force in both windings, ultimately driving the transformer's regulation mechanism.


HUMMELAG electrical component operating principle


The operating principle of a discharge tube is gas gap discharge. i When a specific voltage is applied across the two electrodes of the discharge tube, a non-uniform electric field is generated between them. Under this field, the gas inside the tube begins to ionize. When the external voltage increases to a level where the field strength exceeds the dielectric strength of the gas, the gap breaks down, transitioning from an insulating state to a conductive state. After conduction, the voltage across the electrodes remains at the residual voltage level determined by the discharge arc channel. This residual voltage is generally very low, thereby protecting parallel-connected electronic devices from overvoltage damage.



Weidou Intelligent Technology specializes in selling German HUMMELAG connectors, HUMMELAG switches, HUMMELAG relays, HUMMELAG controllers, HUMMELAG plugs, HUMMELAG sensors, HUMMELAG resistors, HUMMELAG capacitors, HUMMELAG buses, HUMMELAG modules, HUMMELAG cables, HUMMELAG power supplies, HUMMELAG interfaces, HUMMELAG gateways, and HUMMELAG circuit breakers. All HUMMELAG products are original imports from Germany. Customers are welcome to inquire and place orders.