
Indukey electrical components German Indukey models Indukey prices
Indukey electrical components are constituent parts of electronic components and small electrical machines and instruments. They often consist of several parts and are interchangeable within similar products. The term commonly refers to certain parts in the electrical, radio, and instrumentation industries. In practice, electronic components is the collective term for components and devices. Indukey electrical component performance: Fiber optic connector performance primarily involves optical performance. Additionally, factors such as interchangeability, repeatability, tensile strength, temperature, and mating cycles must be considered. 1. Optical performance: Requirements for the optical performance of fiber optic connectors include
- SKU
- _P004837236
- Category
- Electrical and Electronic Components
- Brand
- Indukey
- Tags
- Connectors / Cable / Switch / Relay / Controller / Germany Indukey
Indukey electrical component performance
Fiber optic connector performance primarily involves optical performance. Additionally, factors such as interchangeability, repeatability, tensile strength, temperature, and mating cycles must be considered. 1. Optical performance: Requirements for the optical performance of fiber optic connectors mainly concern the two most basic parameters: insertion loss and return loss. Insertion loss, also known as connection loss, refers to the loss of effective optical power in the link caused by the introduction of the connector. Lower insertion loss is better; generally, it is required to be no greater than 0.5dB. Return loss refers to the connector's ability to suppress optical power reflection in the link. Its typical value should be no less than 25dB. For connectors in practical applications, the ferrule surface undergoes specialized polishing to achieve higher return loss, generally not less than 45dB. 2. Interchangeability and repeatability: Fiber optic connectors are universal passive devices. Connectors of the same type can generally be combined arbitrarily and reused multiple times. The additional loss introduced thereby is typically less than 0.2dB. (3) Tensile strength: For assembled fiber optic connectors, the tensile strength is generally required to be no less than 90N. (4) Temperature: Generally, fiber optic connectors must operate normally within a temperature range of -40oC to +70oC. (5) Mating cycles: Fiber optic connectors in use can generally withstand more than l002 mating cycles.
Indukey electrical component principles
Based on differences in application purposes, various types of thermometers have been designed and manufactured. The design principles include: utilizing the thermal expansion and contraction of solids, liquids, and gases under temperature influence; under constant volume conditions, the pressure of gas (or vapor) changes with temperature; the thermoelectric effect; resistance variation with temperature; and the influence of thermal radiation. 1. Gas thermometer: Hydrogen or helium is mostly used as the temperature-sensing medium, because the liquefaction temperatures of hydrogen and helium are very low, close to absolute zero, so its temperature measurement range is very wide. This type of thermometer has high accuracy and is mostly used for precision measurements. 2. Resistance thermometer: Divided into metal resistance thermometers and semiconductor resistance thermometers, both are made based on the characteristic that resistance value changes with temperature. Metal thermometers mainly use pure metals such as platinum, gold, copper, and nickel, as well as rhodium-iron and phosphor bronze alloys; semiconductor thermometers mainly use carbon, germanium, etc. Resistance thermometers are convenient and reliable to use and have been widely applied. 3. Thermocouple thermometer: It is a temperature measuring instrument widely used in industry. It is made using the thermoelectric phenomenon. Two different metal wires are welded together to form the measuring junction, and the other ends are connected to the measuring instrument to form a circuit. Place the measuring junction at the location where the temperature is to be measured; when the temperature of the measuring junction differs from that of the reference junction, an electromotive force will appear, Therefore, current flows through the circuit. By measuring electrical quantities, using the temperature at a known location, the temperature at another location can be determined. It is suitable for use between two substances with a large temperature difference, and is often used for high-temperature and low-turbidity measurements. 4. Dial thermometer: a thermometer shaped like an instrument panel, also known as a room thermometer, used to measure room temperature, made based on the principle of thermal expansion and contraction of metals. It uses a bimetallic strip as the temperature-sensing element, to control the pointer. The bimetallic strip is usually made by riveting a copper strip and an iron strip together, with the copper strip on the left, and the iron strip on the right. Since the thermal expansion and contraction effect of copper is much more pronounced than that of iron, when the temperature rises, the copper strip pulls the iron strip to bend to the right, and the pointer, driven by the bimetallic strip, deflects to the right (pointing to high temperature); conversely, when the temperature drops, the pointer, driven by the bimetallic strip, deflects to the left. 5. Glass tube thermometer: A glass tube thermometer measures temperature based on the principle of thermal expansion and contraction. Due to the differences in the expansion coefficient, boiling point, and freezing point of the temperature-measuring medium, Therefore, the commonly seen glass tube thermometers mainly include: kerosene thermometers, mercury thermometers, and red fountain pen ink thermometers. Its advantages are simple structure, ease of use, relatively high measurement accuracy, and low price. The disadvantages are that the upper and lower measurement limits and accuracy are limited by the quality of the glass and the properties of the temperature-measuring medium. It cannot transmit signals over long distances, and is fragile. 6. Pressure thermometer: A pressure thermometer uses the liquid in a closed container, gas, or saturated vapor to generate volume expansion or pressure change upon heating as the measurement signal. Its basic structure consists of three parts: the bulb, the capillary tube, and the indicator gauge. The advantages of pressure thermometers are: simple structure, high mechanical strength, resistance to vibration. Low price, no need for external power. The disadvantages are: limited temperature measurement range; large heat loss and slow response time. 9. Mercury thermometers are a type of expansion thermometer, and can only be used as local monitoring instruments. Using them to measure temperature is not only simple and intuitive, but also avoids the errors associated with remote transmission thermometers.
Indukey electrical component characteristics
The static characteristics of a sensor refer to the relationship between the output and input quantities for static input signals. Since the input and output quantities are independent of time in this case, their relationship, i.e., the static characteristics of the sensor, can be described by an algebraic equation without time variables, or by a characteristic curve plotted with the input quantity as the abscissa and the corresponding output quantity as the ordinate. Main parameters characterizing sensor static characteristics include linearity, sensitivity, hysteresis, repeatability, and drift. (1) Linearity: Refers to the degree to which the actual relationship curve between the sensor output and input deviates from the fitted straight line. It is defined as the ratio of the maximum deviation between the actual characteristic curve and the fitted straight line over the full scale range to the full-scale output value. (2) Sensitivity: Sensitivity is an important indicator of sensor static characteristics. It is defined as the ratio of the increment in output quantity to the corresponding increment in input quantity that causes it. S denotes sensitivity. (3) Hysteresis: Hysteresis is the phenomenon where the input-output characteristic curves do not coincide during the change of input quantity from small to large (forward stroke) and from large to small (reverse stroke). For the same magnitude of input signal, the output signals for the forward and reverse strokes are unequal; this difference is called the hysteresis error. (4) Repeatability: Repeatability refers to the degree of inconsistency in the characteristic curves obtained when the sensor input changes continuously multiple times over the full scale in the same direction. (5) Drift: Sensor drift refers to the change in sensor output over time while the input remains constant. There are two causes of drift: one is the sensor's own structural parameters; the other is the surrounding environment (such as temperature and humidity). (6) Resolution: When the sensor input increases slowly from a non-zero value, an observable change in output occurs after exceeding a certain increment. This input increment is called the sensor resolution, i.e., the minimum input increment. (7) Threshold: When the sensor input increases slowly from zero, an observable change in output occurs after reaching a certain value. This input value is called the sensor threshold voltage.
Weidou Intelligent Technology specializes in selling German Indukey connectors, Indukey switches, Indukey relays, Indukey controllers, Indukey plugs, Indukey sensors, Indukey resistors, Indukey capacitors, Indukey buses, Indukey modules, Indukey cables, Indukey power supplies, Indukey interfaces, Indukey gateways, Indukey circuit breakers, Indukey original imports from Germany. Customers are welcome to inquire and order.






