Weidou Intelligent Technology (Shanghai) Co., Ltd.
中文
WDUTECH industrial automation products and services
Categories and filters

Home/Products/ Electrical and Electronic Components

Jager electrical components Germany Jager model Jager price

Jager electrical components Germany Jager model Jager price

Jager electrical components refer to devices that convert chemical energy into electrical energy, consisting of cups, tanks, or other containers or part of the space in composite containers holding electrolyte solutions and metal electrodes to generate current. They have positive and negative terminals. With technological advancements, batteries generally refer to small devices capable of generating electrical energy, such as solar cells. The main performance parameters of batteries include electromotive force, capacity, specific energy, and resistance. Using batteries as an energy source provides stable voltage, stable current, long-term stable power supply, and current minimally affected by external factors. Additionally, batteries have a simple structure.

SKU
_P004837198
Category
Electrical and Electronic Components
Brand
Jager
Tags
Connectors / Cable / Switch / Relay / Controller / German Jager
Jager electrical components refer to devices that convert chemical energy into electrical energy, consisting of cups, tanks, or other containers or part of the space in composite containers holding electrolyte solutions and metal electrodes to generate current. They have positive and negative terminals. With technological advancements, batteries generally refer to small devices capable of generating electrical energy, such as solar cells. The main performance parameters of batteries include electromotive force, capacity, specific energy, and resistance. Using batteries as an energy source provides stable voltage, stable current, long-term stable power supply, and current minimally affected by external factors. Additionally, batteries have a simple structure, are portable, easy to charge and discharge, unaffected by external climate and temperature, and offer stable and reliable performance, playing a significant role in various aspects of modern social life.


Jager electrical component structure


Three basic configurations of fiber optic sensor networks. There are three basic configurations for fiber optic sensor networks, one of which is the single-point sensor. In this configuration, a single fiber serves only as a transmission medium. Another type is the multi-point sensor, where a single fiber connects multiple sensors in series, allowing them to share a light source for networked monitoring. The third type is the intelligent fiber optic sensor. Multi-point fiber optic sensors appear externally as a section of grating with periodic intervals detected via UV exposure. When light enters the fiber, if the wavelength equals twice the interval, strong reflection occurs. If the fiber experiences temperature changes or strain, the reflected wavelength shifts. Multiple such sensors can be placed on a single fiber and connected for various sensing applications. Since fibers are flexible, they can be arranged in two or three dimensions, with the horizontal axis representing spatial position and the vertical axis representing the measured object. This sensor network addresses what happened at which location and with what intensity, providing two-dimensional information. This is the problem intelligent fiber optic sensors aim to solve. They have prominent characteristics, including small size, high strength, good stability, embeddability in materials, electromagnetic interference resistance, and environmental durability.


Jager electrical component characteristics


The main characteristics of circuit breakers include: rated voltage; rated current; tripping current setting range for overload and short-circuit protection; rated short-circuit breaking current, etc. Rated ultimate short-circuit breaking capacity refers to the ability of a low-voltage circuit breaker to operate normally after interrupting the maximum three-phase short-circuit current at its output terminals and to interrupt this short-circuit current once more. The breaker does not guarantee normal connection and disconnection thereafter. Rated service short-circuit breaking capacity refers to the ability of the circuit breaker to interrupt the maximum three-phase short-circuit current at its output terminals multiple times under normal conditions. Rated service short-circuit breaking capacity is a lower breaking current value than the rated ultimate short-circuit breaking current. Generally, circuit breakers with three-stage protection functions (long-time delay for overload, short-time delay for short-circuit, and instantaneous short-circuit trip) can achieve selective protection. Most main lines (including transformer outputs) use them as main protection switches. Circuit breakers without short-time delay for short-circuit (only having long-time delay for overload and instantaneous short-circuit trip) cannot provide selective protection and are suitable only for branch circuits. "Marine Electrical Engineering" points out that circuit breakers with three-stage protection emphasize their service short-circuit breaking capacity, while those used in branch circuits must ensure sufficient ultimate short-circuit breaking capacity. A common bias is to choose larger values rather than appropriate ones, assuming larger is safer. However, excessively large values cause unnecessary waste. Therefore, there is no need to pursue high service short-circuit breaking capacity indicators for branch circuit breakers. For main line circuit breakers, both rated ultimate short-circuit breaking capacity and rated service short-circuit breaking capacity requirements must be met. Circuit breakers are basic low-voltage electrical devices with overload, short-circuit, and undervoltage protection functions, capable of protecting lines and power sources. The main technical indicators are rated voltage and rated current. Circuit breakers have different functions depending on the application, with many varieties, specifications, and specific technical indicators. Free tripping of circuit breakers: If the protective action closes the trip circuit at any moment during the closing process, the circuit breaker can reliably disconnect. This is called free tripping. Circuit breakers with free tripping ensure rapid disconnection in case of short-circuit faults during closing, preventing the expansion of accident scope.


Jager electrical component parameters


1. Stable voltage refers to the stable voltage value generated across the zener diode when it passes through the rated current. This value slightly changes with operating current and temperature. Due to manufacturing differences, the stabilization voltage of the same model of zener diode may not be entirely consistent. 2. Reverse leakage current refers to the current passing through the zener diode when it generates stable voltage. Below this value, the zener diode can still stabilize voltage, but the effect will be poorer; above this value, as long as the rated power loss is not exceeded, it is allowed, and the stabilization performance will be better, though it consumes more electrical energy. 3. Dynamic resistance refers to the ratio of voltage change to current change across the zener diode. This ratio varies with operating current; generally, the higher the operating current, the smaller the dynamic resistance. 4. Rated power consumption is determined by the allowable temperature rise of the chip, calculated as the product of stable voltage and maximum allowable current. 5. Temperature coefficient: If the temperature of the zener diode changes, its stable voltage will also undergo slight changes. The relative change in voltage across the tube caused by a temperature change of 1℃ is the temperature coefficient (unit: %/℃). Generally speaking, stabilization voltages below 6V belong to Zener breakdown, where the temperature coefficient is negative; otherwise, the temperature coefficient is positive. As temperature increases, the depletion layer decreases, and valence electrons in atoms within the depletion layer rise to higher energy levels. A smaller electric field strength can excite valence electrons from atoms, causing Zener breakdown, hence the negative temperature coefficient. Avalanche breakdown occurs when the depletion layer is wider and the electric field strength is lower. Increased temperature amplifies lattice atom vibrations, hindering carrier movement. In this case, only increasing the reverse voltage can cause avalanche breakdown, so the voltage temperature coefficient for avalanche breakdown is positive. For applications with high power supply requirements, two zener diodes with opposite temperature coefficients can be connected in series for compensation. Due to mutual compensation, the temperature coefficient is significantly reduced. 9. Reverse leakage current refers to the leakage current produced by the zener diode under specified reverse voltage.



Weidou Intelligent Technology specializes in selling German Jager connectors, Jager switches, Jager relays, Jager controllers, Jager plugs, Jager sensors, Jager resistors, Jager capacitors, Jager buses, Jager modules, Jager cables, Jager power supplies, Jager interfaces, Jager gateways, Jager circuit breakers, Jager original imports from Germany. Welcome customers to inquire and order.





Recommended products