Weidou Intelligent Technology (Shanghai) Co., Ltd.
WDUTECH industrial automation products and services
Categories and filters

Home/Products/ Electrical and Electronic Components

hugro electrical components, German hugro models, hugro pricing

hugro electrical components, German hugro models, hugro pricing

hugro electrical components are resettable fuses that can be actuated multiple times, known in Japan as permanent fuses. Immediately after interrupting an overload or short-circuit current, the fusible element automatically returns to its original state. The housing is made of austenitic stainless steel, with a beryllium oxide ceramic core embedded in the center. The space between the stainless steel and the ceramic core is filled with glass to provide sealing and secure the ceramic core. Metallic sodium is injected into the fine pores of the ceramic core as the fusible element, and the void behind the piston is filled with argon gas to compress the metallic sodium. Under normal operating conditions, current enters from lead terminal A, passes through the metallic sodium in the fine pores of the ceramic core, and conducts

SKU
_P004836594
Category
Electrical and Electronic Components
Brand
hugro
Tags
Connectors / Cable / Switch / Relay / Controller / German hugro
hugro electrical components are resettable fuses that can be actuated multiple times, known in Japan as permanent fuses. Immediately after interrupting an overload or short-circuit current, the fusible element automatically returns to its original state. The housing is made of austenitic stainless steel, with a beryllium oxide ceramic core embedded in the center. The space between the stainless steel and the ceramic core is filled with glass to provide sealing and secure the ceramic core. Metallic sodium is injected into the fine pores of the ceramic core as the fusible element, and the void behind the piston is filled with argon gas to compress the metallic sodium. Under normal operating conditions, current enters from lead terminal A, passes through the metallic sodium in the fine pores of the ceramic core, conducts to the stainless steel housing, and exits via output terminal B. When a short-circuit current passes through the fuse, it rapidly heats the metallic sodium in the fine pores of the ceramic core, causing it to change from a solid to a high-temperature, high-pressure plasma vapor. The resistivity increases rapidly, thereby strongly limiting the short-circuit current and interrupting it instantaneously. At the end of the interruption, the sodium vapor immediately returns to liquid and solid states, while the argon gas pushes the piston again to compress the metallic sodium, re-establishing the circuit connection.


hugro electrical component parameters


(1) Rated operating voltage: refers to the voltage required by the coil for the relay to operate normally. Depending on the relay model, this can be AC or DC voltage. (2) DC resistance: refers to the DC resistance of the relay coil, which can be measured with a multimeter. (3) Pull-in current: refers to the minimum current required to produce the pull-in action of the relay. For normal operation, the applied current must be slightly greater than the pull-in current to ensure stable relay operation. The voltage applied to the coil should generally not exceed the rated operating voltage; otherwise, excessive current may burn out the coil. (4) Release current: refers to the maximum current at which the relay produces the release action. When the current in the pulled-in state decreases to a certain level, the relay returns to the de-energized released state. This current is significantly lower than the pull-in current. (5) Contact switching voltage and current: refer to the voltage and current loads permitted for the relay contacts. These values determine the magnitude of voltage and current the relay can control. Do not exceed these limits during use, as doing so can easily damage the relay contacts.


hugro electrical component parameters


(1) Rated operating voltage: refers to the voltage required by the coil for the relay to operate normally. Depending on the relay model, this can be AC or DC voltage. (2) DC resistance: refers to the DC resistance of the relay coil, which can be measured with a multimeter. (3) Pull-in current: refers to the minimum current required to produce the pull-in action of the relay. For normal operation, the applied current must be slightly greater than the pull-in current to ensure stable relay operation. The voltage applied to the coil should generally not exceed the rated operating voltage; otherwise, excessive current may burn out the coil. (4) Release current: refers to the maximum current at which the relay produces the release action. When the current in the pulled-in state decreases to a certain level, the relay returns to the de-energized released state. This current is significantly lower than the pull-in current. (5) Contact switching voltage and current: refer to the voltage and current loads permitted for the relay contacts. These values determine the magnitude of voltage and current the relay can control. Do not exceed these limits during use, as doing so can easily damage the relay contacts.


hugro electrical component functions


Antennas radiate radio waves and also receive radio waves. However, what the transmitter feeds into the antenna via the feed line is not radio waves, nor can the receiving antenna directly feed radio waves into the receiver via the feed line; an energy conversion process is required. Taking radio communication equipment as an example, we analyze the signal transmission process to illustrate the energy conversion role of the antenna. At the transmitting end, the modulated high-frequency oscillating current (energy) generated by the transmitter is input to the transmitting antenna via the feeding device (which may directly transmit current waves or electromagnetic waves depending on frequency and form). The transmitting antenna converts the high-frequency current or guided wave (energy) into radio waves—free electromagnetic waves (energy)—radiating them into the surrounding space. At the receiving end, radio waves (energy) are converted by the receiving antenna into high-frequency current or guided waves (energy), which are transmitted to the receiver via the feeding device. From this process, it is evident that the antenna is not only a device for radiating and receiving radio waves but also an energy converter, serving as the interface component between the circuit and space.



Weidou Intelligent Technology specializes in selling German hugro connectors, hugro switches, hugro relays, hugro controllers, hugro plugs, hugro sensors, hugro resistors, hugro capacitors, hugro buses, hugro modules, hugro cables, hugro power supplies, hugro interfaces, hugro gateways, and hugro circuit breakers. All hugro products are original imports from Germany. Customers are welcome to inquire and place orders.





Recommended products