Weidou Intelligent Technology (Shanghai) Co., Ltd.
中文
WDUTECH industrial automation products and services
Categories and filters

Home/Products/ Electrical and Electronic Components

Jager electrical components Germany Jager model Jager price

Jager electrical components Germany Jager model Jager price

Jager electrical components refer to devices that convert chemical energy into electrical energy, consisting of part of the space in cups, tanks, or other containers or composite containers holding electrolyte solutions and metal electrodes to generate current. They have positive and negative terminals. With technological advancements, batteries generally refer to small devices capable of generating electrical energy, such as solar cells. Key performance parameters of batteries include electromotive force, capacity, specific energy, and resistance. Using batteries as an energy source provides stable voltage, stable current, long-term stable power supply, and current minimally affected by external factors, with a simple battery structure.

SKU
_P004836309
Category
Electrical and Electronic Components
Brand
Jager
Tags
Connectors / Cable / Switch / Relay / Controller / German Jager
Jager electrical components refer to devices that convert chemical energy into electrical energy, consisting of part of the space in cups, tanks, or other containers or composite containers holding electrolyte solutions and metal electrodes to generate current. They have positive and negative terminals. With technological advancements, batteries generally refer to small devices capable of generating electrical energy, such as solar cells. Key performance parameters of batteries include electromotive force, capacity, specific energy, and resistance. Using batteries as an energy source provides stable voltage, stable current, long-term stable power supply, and current minimally affected by external factors. The battery structure is simple, portable, easy to charge and discharge, unaffected by external climate and temperature, stable and reliable in performance, playing a significant role in various aspects of modern social life.


Jager electrical component structure


Three basic configurations of fiber optic sensor networks. There are three basic configurations for fiber optic sensor networks, one of which is called the single-point sensor. Here, a single fiber serves only for transmission. Another type is the multi-point sensor, where a single fiber connects many sensors in series, allowing multiple sensors to share a light source for networked monitoring. Then there is the intelligent fiber optic sensor. Multi-point fiber optic sensors appear externally as a section of grating, with periodic intervals discovered through UV exposure. When light enters the fiber, if the wavelength equals twice the interval, the light wave undergoes strong reflection. If the fiber experiences temperature changes or strain, this reflected wavelength shifts. Many such sensors can be made on a single fiber and connected for various sensing applications. Since fiber is flexible, it can be arranged in two or three dimensions, with the horizontal axis representing spatial position and the vertical axis representing the measured object. What problem does such a sensor network solve? It determines what happened at which location and the intensity of that event, providing two-dimensional information. This is the problem intelligent fiber optic sensors aim to solve. They have prominent requirements, including small size, high strength, good stability, embeddability in materials, electromagnetic interference resistance, and environmental durability.


Jager electrical component characteristics


Key characteristics of circuit breakers include: rated voltage; rated current; tripping current setting range for overload and short-circuit protection; rated short-circuit breaking current, etc. Rated ultimate short-circuit breaking capacity refers to the ability of a low-voltage circuit breaker to operate normally again and break the same short-circuit current once more after interrupting the maximum three-phase short-circuit current at its output terminals. The breaker does not guarantee normal closing and breaking thereafter. Rated service short-circuit breaking capacity refers to the ability of the circuit breaker to break normally multiple times when the maximum three-phase short-circuit current occurs at its output terminals. The rated service short-circuit breaking capacity is a breaking current value lower than the rated ultimate short-circuit breaking current. Generally, circuit breakers with three-stage protection functions (long-time delay for overload, short-time delay for short-circuit, and instantaneous short-circuit trip) can achieve selective protection. Most main lines (including transformer outputs) use them as main protection switches. Circuit breakers without short-time delay for short-circuit (only having long-time delay for overload and instantaneous short-circuit trip, i.e., two-stage protection) cannot provide selective protection and are only suitable for branch circuits. "Marine Electrical Engineering" points out that for circuit breakers with three-stage protection, emphasis is placed on their service short-circuit breaking capacity value, while for circuit breakers used in branch lines, sufficient ultimate short-circuit breaking capacity must be ensured. A common bias is to choose larger values rather than appropriate ones, believing larger is safer. However, excessively large values cause unnecessary waste. Therefore, there is no need to blindly pursue high service short-circuit breaking capacity indicators for branch circuit breakers. For circuit breakers used on main lines, they must meet not only the rated ultimate short-circuit breaking capacity requirements but also the rated service short-circuit breaking capacity requirements. A circuit breaker is a basic low-voltage electrical appliance with overload, short-circuit, and undervoltage protection functions, capable of protecting lines and power sources. The main technical indicators are rated voltage and rated current. Circuit breakers have different functions depending on the application, with many varieties and specifications, and numerous specific technical indicators. Free tripping of circuit breakers: If the protection action closes the tripping circuit at any moment during the closing process, the circuit breaker can reliably disconnect completely. This is called free tripping. Circuit breakers with free tripping ensure rapid disconnection during short-circuit faults when closing, preventing the expansion of accident scope.


Jager electrical component parameters


1. Stable voltage refers to the stable voltage value generated across the terminals of a Zener diode when passing the rated current. This value varies slightly with operating current and temperature. Due to manufacturing differences, the stabilization voltage of the same model of Zener diode is not entirely consistent. 2. Reverse leakage current refers to the current passing through the Zener diode when it generates stable voltage. Below this value, the Zener diode can still stabilize voltage, but the effect worsens; above this value, as long as the rated power dissipation is not exceeded, it is allowed, and stabilization performance improves, though it consumes more electrical energy. 3. Dynamic resistance refers to the ratio of voltage change to current change across the Zener diode terminals. This ratio changes with operating current; generally, the higher the operating current, the lower the dynamic resistance. 4. Rated power dissipation is determined by the allowable temperature rise of the chip, calculated as the product of stable voltage and maximum allowable current. 5. Temperature coefficient: If the temperature of the Zener diode changes, its stable voltage undergoes slight changes. The relative change in voltage across the tube terminals caused by a temperature change of 1℃ is the temperature coefficient (unit: %/℃). Generally, stabilization voltages below 6V belong to Zener breakdown, with a negative temperature coefficient; the temperature coefficient is positive. When temperature rises, the depletion layer narrows. In the depletion layer, valence electrons of atoms rise to higher energy levels, and smaller electric field strengths can excite valence electrons from atoms to cause Zener breakdown, hence its negative temperature coefficient. Avalanche breakdown occurs when the depletion layer is wider and electric field strength is lower. Increased temperature amplifies lattice atom vibration amplitude, hindering carrier movement. In this case, only increasing reverse voltage can cause avalanche breakdown, so the voltage temperature coefficient for avalanche breakdown is positive. For applications with high power supply requirements, two Zener diodes with opposite temperature coefficients can be connected in series for compensation. Due to mutual compensation, the temperature coefficient is significantly reduced. 9. Reverse leakage current refers to the leakage current generated by the Zener diode under specified reverse voltage.



Weidou Intelligent Technology professionally sells German Jager connectors, Jager switches, Jager relays, Jager controllers, Jager plugs, Jager sensors, Jager resistors, Jager capacitors, Jager buses, Jager modules, Jager cables, Jager power supplies, Jager interfaces, Jager gateways, Jager circuit breakers, Jager original imports from Germany. Welcome customers to inquire and order.





Recommended products