Bosch Rexroth IH15EA-1X/ADB-S500/D/V Part No. R904100908 Clamping and Drive Module Distribution

R904100908 Bosch Rexroth UPE 2 The clamping and drive module constitutes a complete drive system that is ready for connection upon delivery. It is used to supply hydraulic oil to the hydraulic circuit. For reasons related to thermal load, the clamping and drive module will operate in short-time duty and intermittent duty modes. The duty cycle is selected based on power output and environmental conditions so that the maximum permissible operating temperature of 80 °C is not exceeded. The clamping and drive module basically consists of an aluminum housing, a pump (radial piston pump or external gear pump), and an oil-immersed motor.

SKU
_P004676222
Category
Bosch Rexroth Clamping and Drive Modules
Tags
Clamping and Drive Module / Bosch Rexroth / Rexroth control module / IH15EA-1X/ADB-S500/D/V / R904100908
R904100908 Bosch Rexroth UPE 2 The clamping and drive module constitutes a complete drive system that is ready for connection upon delivery. It is used to supply hydraulic oil to the hydraulic circuit. For reasons related to thermal load, the clamping and drive module will operate in short-time duty and intermittent duty modes. The duty cycle is selected based on power output and environmental conditions so that the maximum permissible operating temperature of 80 °C is not exceeded. The clamping and drive module basically consists of an aluminum housing, a pump (radial piston pump or external gear pump), and an oil-immersed motor. The stator of the oil-immersed motor is pressed into the aluminum housing. It transfers the heat from the windings directly to the outer wall of the aluminum housing. For installation, four through-holes for mounting screws are provided at the bottom of the tank. The clamping and drive module will operate in a vertical installation position. Optionally, the UPE 137 clamping and drive module can be equipped with electronic monitors for oil level and oil temperature monitoring, air filters, and complete hydraulic control. Clamping and drive module


R904100908 Overview of accessory modules for clamping and drive modules


1) Basic module "G": – Basic module with integrated relief valve for simple lowering and holding functions. – If the basic module "G" is used, further stacking is not feasible. – For more details, see the brochure "Control block types for clamping and drive modules. IH15A". 2) Directional valve module "W" 1): – Allows control designs using valves with porting surfaces conforming to DIN 24340 form A. – The number of directional valve modules depends on the discharge volume and pump displacement. – For more details, see the brochure "Control block types for clamping and drive modules IH15A". 3) Seat valve module "S" 1): – The basic composition of a seat valve module includes: • One relief valve block. • One or several control blocks. • One end block. – Control is designed according to the specific application. – The number of seat valve modules depends on the discharge volume and pump displacement. – For more details, see the brochure "Control block types for clamping and drive modules IH150A". Directional valve modules and seat valve modules can be combined!


R904100908 Features and applications of clamping and drive modules


When designing controllers with tanks, ensure that type-tested pressure relief valves protect the tank from impermissible overpressure. Type-tested pressure relief valves must not perform any control tasks, and the set pressure of the type-tested pressure relief valve must be less than or equal to the maximum permissible working pressure of the tank. When using modules SPDB and SPDR at 9 xp (minimum working pressure), a filter with a filtration rating of 6 μm must be used. 1) Connection module type A (see page 74). 2) Connection module with pressure reducing valve type ADB (see page 75). 3) End module type E (see page 78). 4) Intermediate module type Z (page 76). Intermediate modules can also be combined with connection modules. Pos. 1 or can be combined with end module item 3. Length dimensions are calculated by adding the dimension "X" of the directional valve modules (see pages 19 to 21) and the poppet valve modules (see pages 31 to 72). Example: IH15BA006-1X / 07024AA / W220N9K4M01 Nominal size A IH15B assembly up to 14 l/min. With NG6 valve, 7 modules, consecutive numbering 24, variant AA, 220 V AC voltage, N9 manual operation, K4 connection type, sealing material Perbunan, connection type with pipe thread conforming to ISO 228 Part 1. Filter element assembly tool: - With pipe wrench Material No.: R904001048. Installation instructions for F30: - Turn the filter cartridge upward to the stop on the stop. Then rotate the filter cartridge approximately 1/3 turns. Installation instructions for DF30 and DF40: - Rotate the filter cartridge as far as possible. Then turn back approximately 1/8 to 1/139 turns.


R904100908 Motors for clamping and drive modules


The clamping and drive module is designed for short-time duty S2 and intermittent duty S3 operating modes within the nominal power range, in accordance with standard VDE 0530 (EN 60034). The motor conforms to insulation class F, and the entire clamping and drive module conforms to protection class IP 54. The direction of rotation of the motor depends on the installed pump (for this, refer to "Technical Data" on page 4). Motor technical data Voltage 1) U V 230 / 400 ±6 % Δ/Y. Frequency f Hz 50 / 60. Operating mode S2 short-time duty, S3 intermittent duty. Insulation class F (windings). Protection class IP 54. Number of poles 2 / 4. Electromagnetic compatibility of the equipment (EMVG): According to the provisions of the EEC directive "Act on Electromagnetic Compatibility of Equipment (Chapter 2 Section 4)", the clamping and drive module is not a ready-to-use device. To avoid potential electromagnetic interference, we recommend using interference suppression components manufactured by Murr-Elektronik of 71570 Oppenweiler. For example, type 23050, 3 x 400 VAC, 50-195 Hz. Terminal assignment: Terminal assignment in the terminal box on the clamping and drive module.



Weidou Intelligent Technology specializes in selling Bosch Rexroth IH15EA-1X/ADB-S500/D/V Part No. R904100908 clamping and drive modules, R904100908 control modules, R904100908 drive modules, R904100908 clamping modules, R904100908 Bosch Rexroth modules, UPE1336 clamping and drive modules, R904100908 compact modules, R904100908 motor modules, R904100908 hydraulic modules, R904100908 directional valve modules, R904100908 seat valve modules, IH1349MA modules, IH1349EA modules, R904100908 indexing modules, R904100908 release modules, R904100908 original German imports. Welcome inquiries and orders from users.