Bosch Rexroth UPE5-1X/2, 20V7/06-14A-H-0 Part No. R900993172 Clamping and Drive Module Distribution
R900993172 Bosch Rexroth UPE2 clamping and drive module (51142) IH15A control modules are used to implement complete hydraulic control. They can be equipped and assembled individually. Directional valve modules and seat valve modules can be combined with each other, and the control modules can be connected directly to the clamping and drive module UPE2. However, with the aid of external accessory modules, the hydraulic control unit can also be installed in any system. The RBAIH15A type reduction module enables the IH15A module to be mounted directly on conventional
- SKU
- _P004675982
- Category
- Bosch Rexroth Clamping and Drive Modules
- Brand
- R900993172
- Tags
- Clamping and Drive Module / Bosch Rexroth / Rexroth control module / UPE5-1X/2 / 20V7/06-14A-H-0 / R900993172
R900993172 Overview of Accessory Modules for Clamping and Drive Modules
1) Basic module "G": – Basic module with integrated relief valve for simple lowering and holding functions. – If the basic module "G" is used, further stacking is not feasible. – For more details, see the brochure "Control Block Types for Clamping and Drive Modules IH15A". 2) Directional valve module "W" 1): – Design that allows control using valves with port mounting surfaces conforming to DIN 24340 form A. – The number of directional valve modules depends on the discharge volume and pump displacement. – For more details, see the brochure "Control Block Types for Clamping and Drive Modules IH15A". 3) Seat valve module "S" 1): – The basic composition of the seat valve includes: • One relief valve block. • One or several control blocks. • One end block. – Control is designed according to the respective application. – The number of seat valve modules depends on the discharge volume and pump displacement. – For more details, see the brochure "Control Block Types for Clamping and Drive Modules IH111A". Directional valve modules and seat valve modules can be combined!
R900993172 Notes on Commissioning Clamping and Drive Modules
– Please check whether the clamping and drive module has been connected professionally (hydraulically and electrically) to the machine to be operated. – For the electrical connection of the motor, the washers and connection bridges included in the scope of delivery must be used. – The motor must be protected by equipment with an overload relay. The latter must be set to the rated current indicated on the nameplate/rating plate. – When installing the clamping and drive module on an external gear pump, the direction of rotation of the motor must be strictly observed; see the arrow indicating the direction of rotation. (Practical check: Briefly switch on the motor and check whether the pump can transfer fluid.) (Visual check: Remove the air filter on the tank cover, briefly switch on the motor and check the direction of rotation of the rotor shaft.) – Hydraulic oil may only be filled through a filter with the required minimum retention rate. – The clamping and drive module must be filled with hydraulic oil to the maximum level, until the oil level reaches the lower edge of the cover. – The clamping and drive module must absolutely not be operated without hydraulic oil.
R900993172 Motors for Clamping and Drive Modules
The clamping and drive modules are designed for short-time operation S2 and intermittent operation S3 duty cycles within the rated power range, in accordance with VDE 0530 (EN 60034) standards. The motors comply with insulation class F, and the entire clamping and drive module complies with protection rating IP 54. The direction of rotation of the motor depends on the installed pump (see "Technical Data" on page 4). Motor technical data Voltage 1) U V 230 / 400 ±6 % Δ/Y. Frequency f Hz 50 / 60. Duty cycle S2 short-time operation, S3 intermittent operation. Insulation class F (winding). Protection rating IP 54. Number of poles 2 / 4. Electromagnetic compatibility of the equipment (EMVG): According to the provisions of the EEC Directive "Act on Electromagnetic Compatibility of Equipment (Chapter 2, Section 4)", the clamping and drive module is not a ready-to-use device. To avoid possible electromagnetic interference, we recommend using interference suppression components manufactured by Murr-Elektronik from 71570 Oppenweiler. For example, type 23050, 3 x 400 VAC, 50-156 Hz. Terminal assignment, terminal assignment in the junction box on the clamping and drive module.
Weidou Intelligent Technology specializes in the sale of Bosch Rexroth UPE5-1X/2, 20V7/06-14A-H-0 (part number R900993172) clamping and drive modules, R900993172 control modules, R900993172 drive modules, R900993172 clamping modules, R900993172 Bosch Rexroth modules, UPE1096 clamping and drive modules, R900993172 compact modules, R900993172 motor modules, R900993172 hydraulic modules, R900993172 directional valve modules, R900993172 seat valve modules, IH1109MA modules, IH1109EA modules, R900993172 indexing modules, R900993172 release modules, R900993172 original imports from Germany. Customers are welcome to inquire and place orders.