Bosch Rexroth UPE2-1X/1, 1R4, 00/4A-B1V+00266499 Part No. R900260933 Clamping and Drive Module Distribution
R900260933 Bosch Rexroth UPE 2 clamping and drive modules constitute a complete drive system that is ready for connection upon delivery. It is used to supply hydraulic oil to the hydraulic circuit. For reasons related to thermal load, the clamping and drive module will operate in short-time duty and intermittent duty modes. The duty cycle is selected based on power output and environmental conditions so that the maximum permissible operating temperature of 80 °C is not exceeded. The clamping and drive module basically consists of an aluminum housing, a pump (radial piston pump or external gear pump), and an oil-immersed motor.
- SKU
- _P004675329
- Category
- Bosch Rexroth Clamping and Drive Modules
- Brand
- R900260933
- Tags
- Clamping and Drive Module / Bosch Rexroth / Rexroth control module / UPE2-1X/1 / 1R4 / 00/4A-B1V+00266499 / R900260933
R900260933 Overview of accessory modules for clamping and drive modules
1) Basic module "G": – Basic module with integrated relief valve for simple lowering and holding functions. – If basic module "G" is used, further stacking is not feasible. – For more details, see catalog "Control block types for clamping and drive modules. IH15A". 2) Directional valve module "W" 1): – Allows control designs using valves with port mounting surfaces conforming to DIN 24340 form A. – The number of directional valve modules depends on the discharge volume and pump displacement. – For more details, see catalog "Control block types for clamping and drive modules IH15A". 3) Seat valve module "S" 1): – The basic composition of the seat valve includes: • One relief valve block. • One or several control blocks. • One end block. – Control is designed according to the specific application. – The number of seat valve modules depends on the discharge volume and pump displacement. – For more details, see catalog "Control block types for clamping and drive modules IH57A". Directional valve modules and seat valve modules can be combined!
R900260933 Notes on commissioning clamping and drive modules
– Please check whether the clamping and drive module has been professionally connected (hydraulically and electrically) to the machine to be operated. – For the electrical connection of the motor, the washers and connection bridges included in the delivery scope must be used. – The motor must be protected by equipment with an overload relay. The latter must be set to the nominal current indicated on the nameplate/rating plate. – When installing the clamping and drive module on an external gear pump, the direction of rotation of the motor must be strictly observed; see the arrow indicating the direction of rotation. (Practical check: Briefly switch on the motor and check if the pump can transfer fluid.) (Visual check: Remove the air filter on the tank cover, briefly switch on the motor, and check the direction of rotation of the rotor shaft.) – Hydraulic oil may only be filled through a filter with the required minimum retention rate. – The clamping and drive module must be filled with hydraulic oil to the maximum level, until the oil reaches the lower edge of the cover on the dipstick. – Under no circumstances should the clamping and drive module be operated without hydraulic oil.
R900260933 Motor for clamping and drive modules
The clamping and drive module is designed for operation in short-time duty S2 and intermittent duty S3 modes within the nominal power range, in accordance with standard VDE 0530 (EN 60034). The motor conforms to insulation class F, and the entire clamping and drive module conforms to protection class IP 54. The direction of rotation of the motor depends on the installed pump (see "Technical Data" on page 4). Motor technical data Voltage 1) U V 230 / 400 ±6 % Δ/Y. Frequency f Hz 50 / 60. Operating mode S2 short-time duty, S3 intermittent duty. Insulation class F (windings). Protection class IP 54. Number of poles 2 / 4. Electromagnetic compatibility of the equipment (EMVG): According to the provisions of the EEC directive "Act on Electromagnetic Compatibility of Equipment (Chapter 2, Section 4)", the clamping and drive module is not a ready-to-use device. To avoid possible electromagnetic interference, we recommend using interference suppression components manufactured by Murr-Elektronik of 71570 Oppenweiler. For example, type 23050, 3 x 400 VAC, 50-102 Hz. Terminal assignment, terminal assignment inside the junction box on the clamping and drive module.
Weidou Intelligent Technology specializes in the sale of Bosch Rexroth UPE2-1X/1, 1R4, 00/4A-B1V+00266499 item number R900260933 clamping and drive modules, R900260933 control modules, R900260933 drive modules, R900260933 clamping modules, R900260933 Bosch Rexroth modules, UPE443 clamping and drive modules, R900260933 compact modules, R900260933 motor modules, R900260933 hydraulic modules, R900260933 directional valve modules, R900260933 seat valve modules, IH456MA modules, IH456EA modules, R900260933 indexing modules, R900260933 release modules, R900260933 original German imports. Customers are welcome to inquire and place orders.