Weidou Intelligent Technology (Shanghai) Co., Ltd.
中文
WDUTECH industrial automation products and services
Categories and filters

Home/Products/ schmersal switch pilz switch in stock

MICRO DETECTORS switch German MICRO DETECTORS model MICRO DETECTORS price

MICRO DETECTORS switch German MICRO DETECTORS model MICRO DETECTORS price

MICRO DETECTORS switches are used in robots to mimic tactile functions. Tactile sense is an important sensory function when humans directly contact the external environment. Developing tactile switches that meet requirements is one of the technical keys in robot development. With the development of microelectronics and the emergence of various organic materials, a variety of development schemes for tactile switches have been proposed, but most are currently at the laboratory stage, with few reaching commercialization. Tactile switches can be roughly classified by function into contact switches, force-torque switches, pressure switches, and slip switches.

SKU
_P004507626
Category
schmersal switch pilz switch in stock
Tags
Proximity Switch / Germany MICRO DETECTORS / Weighing Switch / Photoelectric Switch / Process Switch / Displacement Switch
MICRO DETECTORS switches are used in robots to mimic tactile functions. Tactile sense is an important sensory function when humans directly contact the external environment. Developing tactile switches that meet requirements is one of the technical keys in robot development. With the development of microelectronics and the emergence of various organic materials, a variety of development schemes for tactile switches have been proposed, but most are currently at the laboratory stage, with few reaching commercialization. Tactile switches can be roughly classified by function into contact switches, force-torque switches, pressure switches, and slip switches.


MICRO DETECTORS switch classification


1) Contact type: The sensing element of a contact temperature switch has good contact with the object being measured; it is also called a thermometer. The thermometer reaches thermal equilibrium through conduction or convection, so that its indication directly represents the temperature of the object being measured. Generally, the measurement accuracy is relatively high. Within a certain temperature measurement range, the thermometer can also measure the internal temperature distribution of an object. However, significant measurement errors occur for moving bodies, small targets, or objects with very small heat capacity. Commonly used thermometers include bimetal thermometers, glass liquid-in-glass thermometers, pressure thermometers, resistance thermometers, thermistors, and thermocouples. They are widely used in industrial, agricultural, commercial, and other sectors. These thermometers are also frequently used in daily life. With the extensive application of cryogenic technology in national defense engineering, space technology, metallurgy, electronics, food, medicine, petrochemicals, and research into superconductivity, cryogenic thermometers for measuring temperatures below 120K have been developed, such as cryogenic gas thermometers, vapor-pressure thermometers, acoustic thermometers, paramagnetic salt thermometers, quantum thermometers, cryogenic resistance thermometers, and cryogenic thermocouples. Cryogenic thermometers require sensing elements that are small in size, highly accurate, and have good reproducibility and stability. A carburized glass resistance thermometer, made by carburizing and sintering porous high-silica oxygen glass, is one type of sensing element for cryogenic thermometers and can be used to measure temperatures in the range of 1.6 to 300K. 2) Non-contact type: Its sensing element does not come into contact with the object being measured; it is also called a non-contact temperature measuring instrument. This instrument can be used to measure the surface temperature of moving objects, small targets, objects with small heat capacity, or objects with rapid (transient) temperature changes, and can also be used to measure temperature field distributions. The most commonly used non-contact temperature measuring instruments are based on the basic laws of blackbody radiation and are called radiation thermometers. Radiation temperature measurement methods include the brightness method (see optical pyrometer), the radiation method (see radiation pyrometer), and the colorimetric method (see colorimetric thermometer). Various radiation temperature measurement methods can only determine the corresponding brightness temperature, radiation temperature, or colorimetric temperature. Only the temperature measured for a blackbody (an object that absorbs all radiation and reflects no light) is the true temperature. To determine the true temperature of an object, correction for the material's surface emissivity is required. Material surface emissivity depends not only on temperature and wavelength but also on surface condition, coatings, and microstructure, making precise measurement difficult. In automated production, radiation temperature measurement is often used to measure or control the surface temperature of certain objects, such as the rolling temperature of steel strips in metallurgy, roll temperature, forging temperature, and the temperature of various molten metals in smelting furnaces or crucibles. In these specific cases, measuring the surface emissivity of the object is quite difficult. For automatic measurement and control of solid surface temperatures, an additional mirror can be used to form a blackbody cavity together with the measured surface. The influence of additional radiation can increase the effective radiation and effective emissivity of the measured surface. By using the effective emissivity to appropriately correct the measured temperature via the instrument, the true temperature of the measured surface can ultimately be obtained. The most typical additional mirror is a hemispherical mirror. Diffuse radiation from the measured surface near the center of the sphere is reflected back to the surface by the hemispherical mirror, forming additional radiation and thereby increasing the effective emissivity, where ε is the material surface emissivity and ρ is the reflectivity of the mirror. For radiation measurement of the true temperature of gaseous and liquid media, a method involving inserting a heat-resistant material tube to a certain depth to form a blackbody cavity can be used. The effective emissivity of the cylindrical cavity after reaching thermal equilibrium with the medium is calculated. In automatic measurement and control, this value can be used to correct the measured temperature at the bottom of the cavity (i.e., the medium temperature) to obtain the true temperature of the medium.


MICRO DETECTORS switch usage precautions


1) Errors introduced by improper installation: For example, the installation position and insertion depth of the thermocouple cannot reflect the true temperature of the furnace chamber. In other words, the thermocouple should not be installed too close to the door or heating elements; the insertion depth should be at least 8 to 10 times the diameter of the protection tube; the gap between the thermocouple protection tube and the wall is not filled with insulating material, causing heat escape from the furnace or cold air intrusion. Therefore, the gap between the thermocouple protection tube and the furnace wall hole should be blocked with insulating materials such as refractory mud or asbestos rope to prevent convection of hot and cold air from affecting temperature measurement accuracy; the cold junction of the thermocouple is too close to the furnace body, causing the temperature to exceed 100℃; the thermocouple installation should avoid strong magnetic and electric fields as much as possible, so thermocouples and power cables should not be installed in the same conduit to avoid introducing interference and causing errors; thermocouples should not be installed in areas where the measured medium flows rarely. When using a thermocouple to measure gas temperature in a pipe, the thermocouple must be installed against the flow direction and have full contact with the gas. 2) Errors introduced by deteriorated insulation: If the thermocouple insulation is compromised, excessive dirt or salt slag on the protection tube and terminal board causes poor insulation between the thermocouple poles and the furnace wall, which is more severe at high temperatures. This not only causes loss of thermoelectric potential but also introduces interference, with resulting errors sometimes reaching hundreds of degrees. 3) Errors introduced by thermal inertia: Due to the thermal inertia of the thermocouple, the instrument's indication lags behind changes in the measured temperature, an effect that is particularly prominent during rapid measurements. Therefore, thermocouples with thinner thermoelectrodes and smaller diameter protection tubes should be used as much as possible. If the temperature measurement environment permits, the protection tube can even be removed. Due to measurement lag, the amplitude of temperature fluctuations detected by the thermocouple is smaller than the amplitude of furnace temperature fluctuations. The greater the measurement lag, the smaller the amplitude of thermocouple fluctuations, and the greater the difference from the actual furnace temperature. When using thermocouples with large time constants for temperature measurement or control, although the temperature displayed by the instrument fluctuates little, the actual furnace temperature fluctuation may be large. To measure temperature accurately, thermocouples with small time constants should be selected. The time constant is inversely proportional to the heat transfer coefficient and directly proportional to the diameter of the thermocouple hot junction, material density, and specific heat. To reduce the time constant, besides increasing the heat transfer coefficient, the most effective method is to minimize the size of the hot junction. In use, materials with good thermal conductivity, thin-walled protection tubes with small inner diameters are typically used. In more precise temperature measurements, bare-wire thermocouples without protection tubes are used, but thermocouples are prone to damage and should be calibrated and replaced in time. 4) Thermal resistance error: At high temperatures, if there is a layer of coal ash or dust on the protection tube, thermal resistance increases, hindering heat conduction, causing the temperature indication to be lower than the true value of the measured temperature. Therefore, the exterior of the thermocouple protection tube should be kept clean to reduce errors.


MICRO DETECTORS switch industry applications


Temperature switches are the earliest developed and most widely used type of switch. The market share of temperature switches greatly exceeds that of other switches. People began using temperature for measurement in the early 17 century. Supported by semiconductor technology, semiconductor thermocouple switches, PN junction temperature switches, and integrated temperature switches were successively developed in this century. Two conductors of different materials, if connected together at a point, will exhibit a potential difference at their unheated parts when this connection point is heated. The value of this potential difference is related to the temperature at the measurement point of the unheated part and the material of these two conductors. This phenomenon can occur over a wide temperature range. If this potential difference is measured precisely, and the ambient temperature of the unheated part is measured, the temperature of the heating point can be accurately determined. Because it requires two conductors of different materials, it is called a 'thermocouple'. Thermocouples made of different materials are used in different temperature ranges, and their sensitivities vary. Thermocouple switches have their own advantages and disadvantages; their sensitivity is relatively low, they are easily affected by environmental interference signals, and they are also susceptible to the temperature drift of preamplifiers, making them unsuitable for measuring minute temperature changes. Since the sensitivity of thermocouple temperature switches is unrelated to the thickness of the material.



Weidou Intelligent Technology specializes in selling German MICRO DETECTORS switches, MICRO DETECTORS proximity switches, MICRO DETECTORS distance switches, MICRO DETECTORS vision switches, MICRO DETECTORS displacement switches, MICRO DETECTORS weighing switches, MICRO DETECTORS speed switches, MICRO DETECTORS photoelectric switches, MICRO DETECTORS position switches, MICRO DETECTORS angle switches, MICRO DETECTORS tactile switches, MICRO DETECTORS temperature switches, MICRO DETECTORS pressure switches, MICRO DETECTORS flow switches, MICRO DETECTORS level switches, MICRO DETECTORS motion switches, MICRO DETECTORS process switches, original German imports, welcome inquiries and orders from users.




Recommended products