Weidou Intelligent Technology (Shanghai) Co., Ltd.
中文
WDUTECH industrial automation products and services
Categories and filters

Home/Products/ ABB controller, bosch controller

GKN Stromag controller, German GKN Stromag model, GKN Stromag price

GKN Stromag controller, German GKN Stromag model, GKN Stromag price

GKN Stromag controller is an electronic system for digital arithmetic operations, specifically designed for industrial environments. It uses a programmable memory to execute instructions for stored logic operations, sequential control, timing, counting, and arithmetic operations, and controls various types of mechanical equipment or production processes through digital or analog input (I) and output (O) interfaces. The programmable controller was developed on the basis of electrical control technology and computer technology, and has gradually evolved into a microprocessor-centric, automated

SKU
_P004503278
Category
ABB controller, bosch controller
Brand
Stromag
Tags
Germany GKN Stromag / Drive / Amplifier / Control Unit / Industrial Computer / Programmable Controller
GKN Stromag controller is an electronic system for digital arithmetic operations, specifically designed for industrial environments. It uses a programmable memory to execute instructions for stored logic operations, sequential control, timing, counting, and arithmetic operations, and controls various types of mechanical equipment or production processes through digital or analog input (I) and output (O) interfaces. The programmable controller was developed on the basis of electrical control technology and computer technology, and has gradually evolved into a new type of industrial control device that integrates automation technology, computer technology, and communication technology with a microprocessor as the core. PLC has been widely used in the automatic control of various production machinery and production processes, becoming one of the most important, most popular, and most widely applied industrial control devices, recognized as one of the three pillars of modern industrial automation (PLC, robotics, CAD/CAM).


GKN Stromag controller classification


Discrete signals: Classified by voltage level, including 220VAC, 110VAC, 24VDC; classified by isolation method, including relay isolation and transistor isolation. Analog signals: Classified by signal type, including current type (4-20mA, 0-20mA), voltage type (0-10V, 0-5V, -10-10V), etc.; classified by precision, including 12bit, 14bit, 16bit, etc. In addition to the above general IO, there are special IO modules, such as RTD, thermocouple, and pulse modules. Module specifications and quantities are determined by the number of I/O points; the number of I/O modules can vary, but the maximum number is limited by the basic configuration management capability of the CPU, i.e., the maximum number of backplane or rack slots.


GKN Stromag controller structure


1) Central Processing Unit (CPU): The Central Processing Unit (CPU) is the control center of the PLC, serving as the neural center of the PLC. Each PLC system has at least one CPU. It receives and stores user programs and data entered from the programmer according to the functions assigned by the PLC system program; checks the status of the power supply, memory, I/O, and watchdog timer, and can diagnose syntax errors in the user program. When the PLC is put into operation, it first receives the status and data of various field input devices in a scanning manner and stores them in the I/O image area respectively. Then, it reads the user program line by line from the user program memory, executes logical or arithmetic operations according to the instructions after command interpretation, and sends the results to the I/O image area or data registers. After all user programs are executed, the output status of the I/O image area or the data in the output registers are transmitted to the corresponding output devices. This cycle continues until operation stops. To further improve the reliability of the PLC, large PLC systems also adopt a redundant system with dual CPU or a voting system with triple CPU. Thus, even if one CPU fails, the entire system can still operate normally. CPU speed and memory capacity are important parameters of the PLC, determining the working speed of the PLC, the number of I/O, and software capacity, thereby limiting the control scale. 2) Memory: System program memory stores system software; user program memory stores PLC user program applications; data memory stores intermediate states and information during PLC program execution, equivalent to the memory of a PC. 3) Input/Output Interface (I/O module): The interface between the PLC and electrical circuits is completed through the input/output section (I/O). The I/O module integrates the PLC I/O circuitry; its input latch reflects the input signal status, and output points reflect the output latch status. Input modules convert electrical signals into digital signals for entry into the PLC system, while output modules do the opposite. I/O is divided into discrete input (DI), discrete output (DO), analog input (AI), analog output (AO), and other modules. 4) Communication Interface: The main function of the communication interface is to realize data exchange (communication) between the PLC and external devices. Communication interfaces come in various forms, with the most basic being standard serial interfaces such as UBS, RS-232, and RS-422/RS-485. Connections can be made via multi-core cables, twisted pair, coaxial cable, optical fiber, etc. 5) Power Supply: The PLC power supply provides operating power for the PLC circuit and plays a very important role in the entire system. A good, reliable power supply system is the most basic guarantee for the PLC. Generally, if the AC voltage fluctuation is within +10% (+15%), the PLC can be directly connected to the AC mains without other measures. Power input types include: AC power (220VAC or 110VAC), DC power (commonly 24VDC).


GKN Stromag controller features


1) High reliability and strong anti-interference capability: PLC uses software to replace a large number of intermediate relays and time relays, leaving only a small amount of hardware related to inputs and outputs. Wiring can be reduced to 1/10~1/100 of that in relay control systems, greatly reducing failures caused by poor contact. High reliability is a key performance indicator for electrical control equipment. PLC adopts modern large-scale integrated circuit technology, strict manufacturing processes, and advanced internal anti-interference technology, resulting in high reliability. For example, the mean time between failures for the Mitsubishi F series PLC is as high as 30 ten thousand hours. Some PLC using redundant CPU have even longer mean time between failures. In terms of external PLC circuitry, using PLC to form a control system reduces electrical wiring and switch contacts to one-hundredth or even one-thousandth of those in relay-contactor systems of the same scale, significantly lowering failure rates. Additionally, PLC has hardware fault self-diagnosis capabilities, issuing alarm information promptly when faults occur. In application software, users can also incorporate peripheral device fault self-diagnosis programs, providing fault self-diagnosis protection for circuits and equipment other than the PLC. Thus, it is no surprise that the entire system has extremely high reliability. 2) Complete hardware support, comprehensive functions, and strong applicability: PLC has developed into serialized products of various sizes (large, medium, and small), and has become standardized, serialized, and modularized. It is equipped with a wide variety of hardware devices for user selection, allowing flexible and convenient system configuration to form systems with different functions and scales. PLC installation and wiring are also convenient, generally using terminal blocks for external connections [3]. PLC has strong load-driving capability, can directly drive general solenoid valves and AC contactors, and can be used in industrial control applications of various scales. In addition to logic processing functions, modern PLC mostly have comprehensive data arithmetic capabilities, suitable for various digital control fields. A large number of PLC function units have emerged, enabling PLC to penetrate into position control, temperature control, CNC, and other industrial controls. Coupled with enhanced PLC communication capabilities and the development of human-machine interface technology, it has become very easy to use PLC to compose various control systems. 3) Easy to learn and use, popular among engineering technicians: As a general-purpose industrial control computer, PLC is industrial control equipment oriented towards industrial and mining enterprises. Its interfaces are easy to use, and its programming language is easily accepted by engineering technicians. The graphical symbols and expression methods of ladder diagram language are quite close to relay circuit diagrams. Using only a few discrete logic control instructions of PLC, the functions of relay circuits can be easily realized. This opens a convenient door for people unfamiliar with electronic circuits, computer principles, and assembly language to use computers for industrial control. 4) Easy to modify: System design, installation, and debugging workload is small, maintenance is convenient, and modification is easy. PLC ladder programs generally adopt sequential control design methods. This programming method is regular and easy to master. For complex control systems, the design time for ladder diagrams is much less than that for designing relay system circuit diagrams. PLC uses stored logic to replace wiring logic, greatly reducing external wiring of control equipment, significantly shortening the design and construction cycle of control systems, and making maintenance easier. More importantly, it makes it possible to change the production process of the same equipment by changing the program. This is very suitable for multi-variety, small-batch production scenarios. 5) Small size, light weight, low energy consumption: Taking ultra-small PLC as an example, recently produced models have a base size of less than 100mm, equivalent to only a few relays, so the volume of the switchgear cabinet can be reduced to 1/2~1/10 of the original. Its weight is less than 150g, and power consumption is only a few watts. Due to its small size, it is easy to install inside machinery, making it an ideal controller for mechatronics integration.



Weidou Intelligent Technology professionally sells German GKN Stromag servo drives, GKN Stromag servo amplifiers, GKN Stromag programmable controllers, GKN Stromag control units, GKN Stromag industrial PCs, GKN Stromag logic controllers, GKN Stromag drum controllers, GKN Stromag relay controllers, GKN Stromag control systems, GKN Stromag motion controllers, GKN Stromag microcontrollers, GKN Stromag control modules, GKN Stromag control switches, GKN Stromag servo controllers, GKN Stromag expansion modules. GKN Stromag original imports from Germany. Welcome customers to inquire and order.