Weidou Intelligent Technology (Shanghai) Co., Ltd.
WDUTECH industrial automation products and services
Categories and filters

Home/Products/ phoenix connectors, telegartner plugs

German wieland plug wieland model wieland price

German wieland plug wieland model wieland price

wieland plug is a control module that can output a signal or provide a discrete on/off signal to actuate controlled equipment when control is required, while also receiving feedback signals from the equipment to report to the host. It is an important component in fire alarm linkage systems. Input/output modules available on the market typically provide one pair of passive normally open/normally closed contacts for controlling the equipment. Some manufacturers' modules can be configured via parameters to provide active outputs (such as GST GST-LD-8301). Corresponding variants include dual input/output modules,

SKU
_P004500383
Category
phoenix connectors, telegartner plugs
Brand
wieland
Tags
Connectors / German wieland / Connector / Interface Module / Terminal Block / Bus Interface
wieland plug is a control module that can output a signal or provide a discrete on/off signal to actuate controlled equipment when control is required, while also receiving feedback signals from the equipment to report to the host. It is an important component in fire alarm linkage systems. Input/output modules available on the market typically provide one pair of passive normally open/normally closed contacts for controlling the equipment. Some manufacturers' modules can be configured via parameters to provide active outputs (such as GST GST-LD-8301). Corresponding variants include dual input/output modules, multi-input/output modules, and others. During a fire alarm, the alarm controller activates external devices requiring linkage via output modules, such as smoke exhaust valves, air supply valves, fire-resistant rolling shutters, fans, and alarm bells, and can receive action confirmation from the devices. The output module is connected to the controller's loop bus and can be installed near the controlled equipment or inside the floor terminal block box. Electronic coding allows for on-site addressing. The output control logic of the output module can be programmed according to project requirements. When the controller receives an alarm signal from a detector, it transmits the linkage control signal to the output module via the bus according to the pre-programmed procedure, and the output module activates the linked fire protection equipment; after the equipment acts, a confirmation signal is received.


wieland plug introduction


Fieldbus is an open interconnection network that can interconnect with networks at the same layer or different layers, and can also achieve shared network databases. Fieldbus embodies the characteristics of distribution, openness, interconnection, and high reliability, which are precisely the shortcomings of DCS systems. DCS typically uses one-to-one separate signal transmission. The analog signals employed have low precision and are susceptible to interference. Operators in the control room often find it difficult to adjust parameters and predict faults for analog instruments, leaving them in an 'out of control' state. Many instrument manufacturers define their own standards, resulting in poor interchangeability. Instrument functions are relatively single-purpose and difficult to meet modern requirements. Moreover, almost all control functions are located in the control station. FCS, on the other hand, adopts one-to-many bidirectional signal transmission. The digital signals used offer high precision and strong reliability. Equipment remains under remote monitoring and controllable status by operators at all times. Users can freely choose devices from different brands and types for interconnection as needed. Smart instruments possess rich functions such as communication, control, and computation, and control functions are distributed among various smart instruments. Thus, we can see the significant progress of FCS compared to DCS. It is precisely due to the above characteristics of FCS that it offers great advantages in design, installation, commissioning, and normal production: Firstly, since intelligent devices at the front end can perform relatively complex tasks, separate controllers and computing units are no longer needed, saving hardware investment and footprint. FCS wiring is relatively simple, and multiple devices can be connected to a single transmission line, greatly reducing installation costs. Since field control devices often have self-diagnostic functions and can send fault information to the control room, maintenance workload is reduced. Meanwhile, users have a high degree of autonomy in system integration and can flexibly select suitable products from manufacturers. The overall system reliability and accuracy are also significantly improved. All this helps users reduce installation, usage, and maintenance costs, ultimately achieving the goal of increasing profits.


wieland plug features


Field control devices have communication capabilities, facilitating the construction of factory-level underlying control networks. Open and consistent communication standards give the system openness and interoperability between devices. Standardization of function blocks and structures ensures interchangeability between devices with identical functions. Distributing control functions to the field gives the control system structure a high degree of decentralization. Fieldbus technology brings automatic control devices and systems into the realm of information networks, opening up broader application areas; multiple control devices can be connected on a single twisted pair, helping to reduce installation costs; lowering maintenance expenses; improving system reliability; and providing users with greater flexibility in system integration.


wieland plug precautions for use


Fieldbus is gradually being promoted in industrial sites. Many devices not only have traditional instrument functions but also possess fieldbus capabilities. In DCS, fieldbus is widely applied. The following issues should be noted when using fieldbus: 1) Communication distance. Fieldbus communication distance generally has certain requirements. For example, PROFIBUS/DP at a rate of 12Mbps can reach 200m using standard cable. If using a rate of 187.5kbps, it can reach 1 000m. Communication distance has two meanings: first, the distance achievable between two nodes without repeaters; generally, distance is inversely proportional to communication rate. Second, the distance between the two farthest nodes in the entire network. Manufacturers' introductory materials often lack clarity on this description. In actual use, the scope of the entire network must be considered. Electromagnetic wave signals take time to propagate through cables. Especially in some high-speed fieldbuses, if the distance is increased, certain communication parameters must be modified. 2) Cable selection. The field environment determines the fieldbus communication speed and medium. Generally, fieldbus uses electrical signals to transmit data, inevitably affected by the surrounding electromagnetic environment during transmission. Most fieldbuses use shielded twisted pairs. It must be noted that different types of fieldbuses may require different shielded twisted pairs. Fieldbus developers generally specify a special cable, and the specified rate and transmission distance can only be achieved when this cable is used correctly. Under extremely harsh electromagnetic conditions, optical fiber is a reasonable choice; otherwise, local interference may affect the operation of the entire fieldbus network. 3) Isolation. Generally, fieldbus electrical signals are electrically isolated from the interior of the device. Fieldbus cables are distributed throughout the workshop. If high voltage intrudes, it will damage the bus transceivers of all devices in the network segment. Without isolation, high voltage signals will continue to damage other internal circuits of the device, leading to serious consequences. 4) Shielding. The outer layer of the shielded cable used for fieldbus must be grounded at a single point. If high-frequency interference is severe, multi-point capacitive grounding can be used. Multi-point direct grounding is not allowed to avoid ground loop currents. 5) Connectors. Fieldbus generally does not have strict regulations on connectors, but improper handling can affect the communication of the entire system. For example, fieldbus generally uses a bus-type daisy chain connection. When connecting each device, attention must be paid to how to insert and remove devices without affecting existing communication, which places certain requirements on connectors. 6) Termination matching. Fieldbus signals, like all electromagnetic wave signals, exhibit reflection phenomena. Resistive matching should be used at both ends of each network segment of the bus. The first purpose is to absorb reflections, and the second is to achieve correct voltage levels at both ends of the bus to ensure communication. Therefore, fieldbus technology is the intersection and integration of control, computer, and communication technologies. Its emergence and rapid development reflect the control field's requirements for reducing costs, improving reliability, enhancing maintainability, and increasing the intelligence of data acquisition.



Weidou Intelligent Technology professionally sells German wieland connectors, wieland connectors, wieland interface modules, wieland terminal blocks, wieland bus interfaces, wieland bus modules, wieland communication modules, wieland fieldbus, wieland plug interfaces, wieland communication interfaces, wieland adapters, wieland output modules, wieland distributor converters, wieland plug bus, wieland expansion modules, wieland original German imports. Welcome customers to inquire and order.





Recommended products