Weidou Intelligent Technology (Shanghai) Co., Ltd.
中文
WDUTECH industrial automation products and services
Categories and filters

Home/Products/ phoenix connectors, telegartner plugs

German MINIMAX plug MINIMAX model MINIMAX price

German MINIMAX plug MINIMAX model MINIMAX price

MINIMAX plugs are conductive devices that bridge two conductors in a circuit, allowing current or signals to flow from one conductor to another. They are widely used in various electrical circuits to connect or disconnect current or signals. This connection may be temporary and convenient for plugging and unplugging at any time, or it may be a permanent node between electrical equipment or wires. Electronic connectors are devices that transmit electronic signals (analog or digital signals), providing a separable interface to connect two sub-electronic systems. They are components used to complete electrical connections between circuits or electronic machines.

SKU
_P004500126
Category
phoenix connectors, telegartner plugs
Brand
MINIMAX
Tags
Connectors / Germany MINIMAX / Connector / Interface Module / Terminal Block / Bus Interface
MINIMAX plugs are conductive devices that bridge two conductors in a circuit, allowing current or signals to flow from one conductor to another. They are widely used in various electrical circuits to connect or disconnect current or signals. This connection may be temporary and convenient for plugging and unplugging at any time, or it may be a permanent node between electrical equipment or wires. Electronic connectors are devices that transmit electronic signals (analog or digital signals), providing a separable interface to connect two sub-electronic systems. They are components used to complete electrical connections between circuits or electronic machines. Examples include power plugs/sockets, IC sockets, and telephone line plugs. They are widely used in the electronics industry. An electronic connector is an electromechanical system that provides a separable interface to connect two sub-electronic systems. Simply put, components used to complete electrical connections between circuits or electronic machines are called connectors, acting as a bridge between them. Electronics can serve as electrical/electronic transmission and connection components between circuits, components, and systems, enabling stable and reliable flow of power, signals, and current, while facilitating product assembly, maintenance, and replacement.


MINIMAX plug structure


An electrical connector consists of a fixed-end electrical connector, i.e., the female contact (referred to as the socket), and a free-end electrical connector, i.e., the male contact (referred to as the plug). The socket is mounted on the powered component via its square (or round) flange (some are also welded), while the plug is generally connected to a cable, with the plug–socket connection achieved through a coupling nut. An electrical connector comprises three basic units: the housing, the insulator, and the contacts. 1) Housing: The housing of an electrical connector refers to the outer shell of the plug and socket, the coupling nut, and the rear accessories. The shell protects internal components such as the insulator and contacts (collective term for pins and sockets) from damage. Positioning keyways ensure proper alignment between the plug and socket. The coupling nut is used for mating and unmating the plug and socket. Rear accessories protect the wire-to-contact termination points from damage and secure the cable. The housing also provides a degree of electromagnetic shielding. Housings are typically machined from aluminum alloy (by machining, cold extrusion, or die casting). Steel housings are mostly used for glass-sealed and high-temperature-resistant electrical connectors. 2) Insulator: Comprises pin-holding insulators, socket-holding insulators, interface seals, wire seals, etc. It maintains pins and sockets in their designated positions and provides electrical insulation between individual contacts and between the contacts and the housing. Sealing measures are achieved by combining the insulator with interface seals and wire seals to enhance the environmental resistance of the electrical connector. To withstand high and low temperatures, meet flame-retardant requirements, and ensure stable and reliable geometric dimensions of the parts, insulators are mostly molded from thermosetting plastics. Interface seals and wire seals are formed by molding silicone rubber, among other methods. 3) Contacts: Contacts include male and female contacts, sometimes referred to as pins and sockets. Connection methods include soldering, crimping, press-fit, and wire-wrapping, used to establish circuit connections. Pins and sockets are critical components of an electrical connector, directly affecting its reliability. Pins and sockets are mostly machined from elastic copper alloys with good conductivity, and their surfaces are silver- or gold-plated to achieve low contact resistance and corrosion resistance. Sockets generally include split-type sockets, wire-spring sockets, crown-spring sockets, and stamped sockets. Structural features include: environmental resistance, bayonet (quick) connection, multiple keyways (to prevent incorrect mating), crimped connection between contacts and wires (facilitating fault handling with single-wire insertion/removal). The housing plus a shielding ring ensures 360° electromagnetic interference shielding capability.


MINIMAX plug classification


Industrial bus networks can be categorized into three types: 485 networks, HART networks, and FieldBus fieldbus networks. 485 network: RS485/MODBUS is a popular industrial networking method, characterized by simple and convenient implementation, and there are many instruments supporting RS485. Instrument manufacturers have also turned to support RS485/MODBUS for the simple reason that RS485 conversion interfaces are not only inexpensive but also diverse. At least in the low-end market, RS485/MODBUS will remain the primary industrial networking method. HART network: HART is a transitional bus standard proposed by Emerson, mainly characterized by superimposing digital signals on a 4-20 mA current signal. However, this protocol is not truly open; one must join its foundation to obtain the protocol, which requires a certain fee. HART technology is mainly monopolized by a few large foreign companies. In recent years, domestic companies have also been working on it, but have not yet reached the level of foreign companies. Many smart instruments come with [HART round card] and support HART communication functions. However, from the domestic perspective, this functionality has not been truly utilized for device networking and monitoring; at most, handheld configurators are used for parameter setting. In the long run, due to reasons such as low HART communication speed and difficult networking, the application of HART instruments will show a downward trend. FieldBus Fieldbus network: Fieldbus is one of the hot technologies in the automation field today, hailed as the computer LAN of the automation field. Its emergence marks the beginning of a new era in automation control technology. Fieldbus is a digital, serial, multi-station communication network connecting instruments at the control site with control devices in the control room. Its key hallmark is the ability to support bidirectional, multi-node, bus-style fully digital communication. Fieldbus technology has become a hotspot in the development of international automation and instrumentation. Its emergence has brought revolutionary changes to traditional control system structures, further advancing automatic control systems towards "intelligence, digitization, informatization, networking, and decentralization," forming a new type of network-communication-based fully distributed control system—the Fieldbus Control System FCS (Fieldbus Control System). However, fieldbus has not yet formed a truly unified standard. Multiple standards such as ProfiBus, CANbus, and CC-Link coexist, each with its own niche. When they will be unified is uncertain. There are relatively few types of instruments supporting fieldbus, leaving little room for choice, higher prices, and smaller usage volumes.


MINIMAX plug safety parameters


1) Insulation resistance: Insulation resistance refers to the resistance value presented by leakage current generated on or within the surface of the insulating part of a connector when voltage is applied. It is mainly affected by factors such as insulating material, temperature, humidity, and contamination. The insulation resistance values provided in connector catalogs are generally indicators under standard atmospheric conditions; under certain environmental conditions, insulation resistance values will decrease to varying degrees. Also, note the test voltage value for insulation resistance. According to Insulation Resistance (MΩ) = Voltage applied to the insulator (V) / Leakage Current (μA), applying different voltages yields different results. In connector tests, the applied voltages generally have three levels: 10V, 100V, and 500V. 2) Rated voltage: Dielectric strength is the critical voltage that the mutual insulation parts of contact pairs, or between insulation parts and ground, can withstand within a specified time without breakdown, exceeding the rated voltage. It is mainly affected by contact pair spacing and creepage distance, geometric shape, insulator material, as well as environmental temperature and humidity, and atmospheric pressure. 3) Mechanical life: The mechanical life of a connector refers to its mating cycle life, typically specified as 500 to 1000 cycles. When this specified mechanical life is reached, indicators such as contact resistance, insulation resistance, and dielectric strength of the connector should not exceed specified values. Strictly speaking, mechanical life is related to time; using 500 cycles over 10 years is obviously different from using 500 cycles over 1 years. First, select the number of contact pairs based on circuit needs, while considering the volume of the connector and the total separation force. A larger number of contact pairs naturally results in a larger volume and a relatively larger total separation force. In cases where high reliability is required and volume allows, two contact pairs can be connected in parallel to improve connection reliability. In connector plugs and sockets, pins (male contacts) and sockets (female contacts) are generally interchangeable. In actual use, selection can be made based on the live status at both ends of the plug and socket. For example, if the socket needs to be constantly live, choose a socket with female contacts, because the live contacts are embedded in the insulator, making them less accessible to human touch, which is relatively safer. Mainly consider the electrical continuity of contact pairs during vibration, shock, and collision under specified frequency and acceleration conditions. Contact pairs may experience instantaneous disconnection under such dynamic stress. Specified instantaneous interruption times generally include 1μs, 10μs, 100μs, 1ms, and 10ms. Note how to judge instantaneous interruption faults in contact pairs. Currently, it is considered that a fault in a closed contact pair (contact) occurs when the voltage drop across its two ends exceeds 50% of the power source electromotive force. That is, there are two conditions for judging instantaneous interruption: duration and voltage drop, both of which are indispensable. Connectors generally consist of plugs and sockets, where the plug is also called a free-end connector, and the socket is also called a fixed connector. Circuit connection and disconnection are achieved through the mating and separation of plugs and sockets, leading to various connection methods for plugs and sockets. For circular connectors, the main methods are threaded connection, bayonet connection, and push-pull (ball-lock) connection. Among these, threaded connection is the most common, offering advantages such as simple processing technology, low manufacturing cost, and wide applicability, but the connection speed is slow, making it unsuitable for occasions requiring frequent mating and quick connections. Bayonet connection has a faster connection speed due to the longer lead of its three bayonet slots, but its manufacturing is more complex and the cost is higher. Push-pull connection is the fastest among the three connection methods; it does not require rotational motion, only linear motion to achieve connection, separation, and locking. Since it belongs to the straight push-pull connection method, it is only suitable for connectors with small total separation force. It is generally more common in small connectors.



Weidou Intelligent Technology professionally sells German MINIMAX connectors, MINIMAX connectors, MINIMAX interface modules, MINIMAX terminal blocks, MINIMAX bus interfaces, MINIMAX bus modules, MINIMAX communication modules, MINIMAX fieldbus, MINIMAX plug interfaces, MINIMAX communication interfaces, MINIMAX adapters, MINIMAX output modules, MINIMAX distributor converters, MINIMAX plug bus, MINIMAX expansion modules, MINIMAX original German imports. Welcome customers to inquire and order.





Recommended products