
German FHF Funke+Huster plug FHF Funke+Huster model FHF Funke+Huster price
FHF Funke+Huster plug is the public communication backbone for transmitting information between various functional components of a computer. It is a transmission bundle composed of wires. According to the types of information transmitted by the computer, the computer bus can be divided into data bus, address bus, and control bus, which are used to transmit data, data addresses, and control signals, respectively. The bus is an internal structure; it is the common channel for cpu, memory, input, and output devices to transmit information. The various components of the host are connected via the bus, and external devices are connected via corresponding interface circuits.
- SKU
- _P004499940
- Category
- phoenix connectors, telegartner plugs
- Brand
- FHF Funke+Huster
- Tags
- Connectors / Germany FHF Funke+Huster / Connector / Interface Module / Terminal Block / Bus Interface
FHF Funke+Huster plug working principle
If the motherboard (Mother Board) is a city, then the bus is like the public buses (bus) in the city, capable of transmitting bits (bit) that operate back and forth along fixed routes. These lines can only be responsible for transmitting one bit at a time. Therefore, multiple lines must be used simultaneously to transmit more data. The number of data items the bus can transmit simultaneously is called the width (width), measured in bits. The greater the bus width, the better the transmission performance. The bus bandwidth (i.e., the total amount of data that can be transmitted per unit time) is: Bus Bandwidth = Frequency x Width (Bytes/sec). When the bus is idle (other devices are connected to the bus in a high-impedance state) and a device needs to communicate with a target device, the initiating device drives the bus, issuing address and data. Other devices connected to the bus in a high-impedance state, upon receiving (or being able to receive) address information matching their own, accept the data on the bus. After the sending device completes communication, it releases the bus (output becomes high-impedance).
FHF Funke+Huster plug classification
Buses can be divided into five major types according to function and specification: Data Bus (Data Bus): Transmits data to be processed or stored back and forth between CPU and RAM. Address Bus (Address Bus): Used to specify the address of data stored in RAM (Random Access Memory). Control Bus (Control Bus): Transmits signals from the microprocessor control unit (Control Unit) to peripheral devices. Expansion Bus (Expansion Bus): A bus for data communication between external devices and the computer host, such as ISA bus and PCI bus. Local Bus (Local Bus): Replaces expansion buses for higher-speed data transmission. Among these, the Data Bus DB (Data Bus), Address Bus AB (Address Bus), and Control Bus CB (Control Bus) are collectively referred to as the system bus, commonly known as the bus. In some systems, the data bus and address bus are multiplexed, meaning the signals on the bus represent data at certain times and addresses at others; in other systems, they are separate. The address bus and data bus of the 51 series microcontrollers are multiplexed, whereas the buses in general PC systems are separate. "Data Bus DB" is used to transmit data information. The data bus is a bidirectional tri-state bus, meaning it can transmit data from CPU to memory or other components such as I/O interfaces, and can also transmit data from other components to CPU. The bit width of the data bus is an important indicator of a microcomputer, usually consistent with the word length of the microprocessor. For example, the Intel 8086 microprocessor has a word length of 16 bits, and its data bus width is also 16 bits. It should be noted that the meaning of data is broad; it can be actual data, instruction codes, or status information, and sometimes even control information. Therefore, in practical work, what is transmitted on the data bus is not necessarily strictly defined as data.
FHF Funke+Huster plug safety parameters
1) Insulation Resistance: Insulation resistance refers to the resistance value presented by leakage current generated on or within the surface of the insulating part when voltage is applied to the insulating part of the connector. It is mainly affected by factors such as insulation material, temperature, humidity, and contamination. The insulation resistance values provided in connector catalogs are generally indicators under standard atmospheric conditions; under certain environmental conditions, the insulation resistance value will decrease to varying degrees. Additionally, pay attention to the test voltage value for insulation resistance. Based on Insulation Resistance (MΩ) = Voltage applied to the insulator (V) / Leakage Current (μA), applying different voltages yields different results. In connector testing, the applied voltages generally have three levels: 10V, 100V, and 500V. 2) Rated Voltage: Dielectric strength is the critical voltage that the mutual insulation parts of contact pairs or the insulation parts and ground can withstand within a specified time without breakdown, exceeding the rated voltage. It is mainly affected by contact pair spacing, creepage distance, geometric shape, insulator material, ambient temperature and humidity, and atmospheric pressure. 3) Mechanical Life: The mechanical life of a connector refers to its mating/unmating cycle life, typically specified as 500 to 1000 cycles. When this specified mechanical life is reached, indicators such as contact resistance, insulation resistance, and dielectric strength of the connector should not exceed specified values. Strictly speaking, mechanical life is related to time; using 500 cycles over 10 years is obviously different from using 500 cycles over 1 years. First, select the number of contact pairs based on circuit requirements, while considering the connector's volume and total separation force. A larger number of contact pairs naturally results in a larger volume and relatively greater total separation force. In cases with high reliability requirements where volume permits, two contact pairs can be connected in parallel to improve connection reliability. In connector plugs and sockets, pins (male contacts) and sockets (female contacts) are generally interchangeable. In actual use, selection can be made based on the energized status at both ends of the plug and socket. For example, if the socket needs to remain energized, choose a socket equipped with female contacts, because the energized contacts are embedded in the insulator, making them less accessible to human touch and relatively safer. Mainly consider the electrical continuity of contact pairs during vibration, shock, and collision under specified frequency and acceleration conditions. Contact pairs may experience instantaneous open circuits under such dynamic stress. Specified instantaneous interruption times generally include 1μs, 10μs, 100μs, 1ms, and 10ms. Note how to judge instantaneous interruption faults in contact pairs. Currently, it is considered that a fault in a closed contact pair (contact) is determined when the voltage drop across its ends exceeds 50% of the power source electromotive force. That is, there are two conditions for judging instantaneous interruption: duration and voltage drop, both of which are indispensable. Connectors generally consist of plugs and sockets, where the plug is also called a free-end connector, and the socket is also called a fixed connector. Circuit connection and disconnection are achieved through the mating and unmating of plugs and sockets, resulting in various connection methods for plugs and sockets. For circular connectors, the main methods are threaded coupling, bayonet coupling, and push-pull (ball-lock) coupling. Threaded coupling is the most common, offering advantages such as simple processing technology, low manufacturing cost, and wide applicability, but it has a slower connection speed and is not suitable for frequent mating/unmating and rapid connections. Bayonet coupling has a faster connection speed due to the longer lead of its three bayonet slots, but it is more complex to manufacture and has a higher cost. Push-pull coupling is the fastest among the three connection methods; it does not require rotational motion, achieving connection, separation, and locking through linear motion only. As it belongs to the straight push-pull connection method, it is only suitable for connectors with low total separation force. It is generally more common in small connectors.
Weidou Intelligent Technology professionally sells German FHF Funke+Huster connectors, FHF Funke+Huster connectors, FHF Funke+Huster interface modules, FHF Funke+Huster terminal blocks, FHF Funke+Huster bus interfaces, FHF Funke+Huster bus modules, FHF Funke+Huster communication modules, FHF Funke+Huster fieldbus, FHF Funke+Huster plug interfaces, FHF Funke+Huster communication interfaces, FHF Funke+Huster adapters, FHF Funke+Huster output modules, FHF Funke+Huster distributor converters, FHF Funke+Huster plug buses, FHF Funke+Huster expansion modules, FHF Funke+Huster original German imports. Welcome customers to inquire and order.






