
German ELEKTROBA plug, ELEKTROBA model, ELEKTROBA price
ELEKTROBA plug terminal blocks, as a type of connector, are important components in the electrical industry, playing an irreplaceable and significant role. Since engineering technicians start troubleshooting by checking interfaces, i.e., terminals, the design of terminal blocks is particularly important. Terminal blocks can be classified into: European-style terminal block series, pluggable terminal block series, transformer terminal blocks, building wiring terminals, barrier-type terminal blocks, spring-type terminal blocks, DIN rail-mounted terminal blocks, wall-through terminal blocks, and optocoupler-type terminals.
- SKU
- _P004499893
- Category
- phoenix connectors, telegartner plugs
- Tags
- Connectors / Connector / Interface Module / Terminal Block / Bus Interface / Germany ELEKTROBA
ELEKTROBA plug structure
An electrical connector consists of a fixed-end electrical connector, i.e., female contacts (referred to as socket), and a free-end electrical connector, i.e., male contacts (referred to as plug). The socket is fixed to the powered equipment via its square (or round) flange (some also use welding methods). The plug is generally connected to a cable, and the connection between the plug and socket is achieved through a coupling nut. An electrical connector is composed of three basic units: housing, insulator, and contacts. 1) Housing: The housing of an electrical connector refers to the outer shell of the plug and socket, the coupling nut, and the rear accessories. The function of the outer shell is to protect internal components such as insulators and contacts (collectively referred to as pins and sockets) from damage. The positioning key slots on the top ensure proper alignment of the plug and socket. The coupling nut is used for connecting and disconnecting the plug and socket. Rear accessories are used to protect the wire-to-contact termination points from damage and to secure the cable. The housing also provides a certain degree of electromagnetic shielding. Housings are generally made from aluminum alloy (machined, cold extruded, or die-cast). Steel housings are mostly used for glass-sealed and high-temperature resistant electrical connectors. 2) Insulator: Composed of pin insulators, socket insulators, interface seals, and wire seals. It is used to keep pins and sockets in their designated positions and to provide electrical insulation between individual contacts and between contacts and the housing. Sealing measures are achieved through insulators combined with interface seals and wire seals to improve the environmental resistance of the electrical connector. To adapt to high temperature, low temperature, and flame retardancy requirements, and to ensure stable and reliable geometric dimensions of parts, insulators are mostly molded from thermosetting plastics. Interface seals and wire seals are formed by molding silicone rubber, etc. 3) Contacts: Contacts include male and female contacts, sometimes referred to as pins and sockets. Connection methods include soldering, crimping, press-fit, and wire wrapping, used to achieve circuit connections. Pins and sockets are key components of electrical connectors, directly affecting their reliability. Pins and sockets are mostly machined from elastic copper alloys with good conductivity, and surfaces are silver- or gold-plated to achieve low contact resistance and corrosion resistance. Sockets generally include split-type sockets, wire-spring sockets, crown-spring sockets, and stamped sockets. Structural features include: environmental resistance, bayonet (quick) connection, multi-key positioning (anti-misinsertion), crimped connection between contacts and wires (single-wire insertion/removal facilitates fault handling). The housing plus a shielding ring ensures 360° electromagnetic interference shielding capability.
ELEKTROBA plug classification
1) By shape: circular electrical connectors, rectangular electrical connectors. Circular electrical connectors are most widely used in military equipment (aviation, aerospace) due to their structural characteristics. Rectangular electrical connectors, due to their simple structure, are more commonly used on printed circuit boards of electronic devices. 2) By structure: By connection method: threaded connection, bayonet (quick) connection, latch connection, push-pull connection, direct plug-in connection, etc.; By contact termination form: crimping, soldering, wire wrapping; screw (cap) fixation; By environmental protection: environmental-resistant electrical connectors and standard electrical connectors. 3) By application: RF electrical connectors, sealed electrical connectors (glass-sealed), high-temperature electrical connectors, automatic drop-away separation electrical connectors, filter electrical connectors, composite material electrical connectors, airport power supply electrical connectors, printed circuit board electrical connectors, etc.
ELEKTROBA plug usage precautions
Fieldbus is gradually being promoted in industrial sites. Many devices not only have traditional instrument functions but also possess fieldbus capabilities. In DCS, fieldbus is widely applied. The following issues should be noted when using fieldbus: 1) Communication distance. Fieldbus communication distance generally has certain requirements. For example, PROFIBUS/DP at a rate of 12Mbps can reach 200m using standard cable. If a rate of 187.5kbps is used, it can reach 1 000m. Communication distance has two meanings: first, the distance achievable between two nodes without repeaters; generally, distance is inversely proportional to communication rate; second, the distance between the two farthest nodes in the entire network. Manufacturers' descriptive materials are often unclear on this point. In actual use, the scope of the entire network must be considered. Electromagnetic signals take time to propagate through cables. Especially in some high-speed fieldbuses, if the distance is increased, certain communication parameters must be modified. 2) Cable selection. The site environment determines the fieldbus communication speed and medium. Generally, fieldbus uses electrical signals to transmit data, which are inevitably affected by the surrounding electromagnetic environment during transmission. Most fieldbuses use shielded twisted pair cables. It must be noted that different types of fieldbuses may require different shielded twisted pair cables. Fieldbus developers generally specify a special type of cable, and the specified rate and transmission distance can only be achieved when this cable is used correctly. Under extremely poor electromagnetic conditions, optical fiber is a reasonable choice; otherwise, local interference may affect the operation of the entire fieldbus network. 3) Isolation. Generally, fieldbus electrical signals are electrically isolated from the device interior. Fieldbus cables are distributed throughout various corners of the workshop. If high voltage intrudes, it will damage the bus transceivers of all devices on the network segment. Without isolation, high voltage signals will continue to damage other internal circuits of the device, leading to serious consequences. 4) Shielding. The outer layer of the shielded cable used for fieldbus must be grounded at a single point. If high-frequency interference is severe, multi-point capacitive grounding can be used. Multi-point direct grounding is not allowed to avoid ground loop currents. 5) Connectors. Fieldbus generally does not have strict regulations on connectors, but improper handling can affect system-wide communication. For example, fieldbus generally uses a bus-type daisy-chain connection method. When connecting each device, attention must be paid to how to insert and remove devices without affecting existing communication, which places certain requirements on connectors. 6) Termination matching. Fieldbus signals, like all electromagnetic wave signals, exhibit reflection phenomena. Resistive matching should be used at both ends of each network segment of the bus. The first function is to absorb reflections, and the second is to achieve correct voltage levels at both ends of the bus to ensure communication. Therefore, fieldbus technology is the intersection and integration of control, computer, and communication technologies. Its emergence and rapid development reflect the control field's requirements for reducing costs, improving reliability, enhancing maintainability, and increasing the intelligence of data acquisition.
Weidou Intelligent Technology specializes in selling German ELEKTROBA connectors, ELEKTROBA plugs, ELEKTROBA interface modules, ELEKTROBA terminal blocks, ELEKTROBA bus interfaces, ELEKTROBA bus modules, ELEKTROBA communication modules, ELEKTROBA fieldbus, ELEKTROBA plug interfaces, ELEKTROBA communication interfaces, ELEKTROBA adapters, ELEKTROBA output modules, ELEKTROBA distributor converters, ELEKTROBA plug bus, ELEKTROBA expansion modules. ELEKTROBA original imported from Germany. Welcome customers to inquire and order.






