
German EFFEKTA plug EFFEKTA model EFFEKTA price
EFFEKTA plug is a common line or path used in computers to connect various functional components and transmit data between them. In computer systems, buses can be classified according to the objects they connect: chip bus, also known as device-level bus, which is the bus inside the central processor chip; internal bus, also known as system bus or board-level bus, which is the transmission path between various functional components of the computer, and the microcomputer bus is usually called the internal bus; external bus, also known as communication bus, which is between computer systems, or between the computer host and peripheral devices.
- SKU
- _P004499886
- Category
- phoenix connectors, telegartner plugs
- Brand
- EFFEKTA
- Tags
- Connectors / Connector / Interface Module / Terminal Block / Bus Interface / Germany EFFEKTA
EFFEKTA plug introduction
Any microprocessor must be connected to a certain number of components and peripheral devices. However, if each component and every peripheral device were directly connected to the CPU with separate sets of wires, the wiring would become intricate and complex, making implementation difficult or even unfeasible. To simplify hardware circuit design and system architecture, a common set of lines, equipped with appropriate interface circuits, is used to connect various components and peripheral devices. This shared connection pathway is known as a bus. Adopting a bus structure facilitates the expansion of components and devices; especially when unified bus standards are established, interconnection between different devices becomes easier. In microcomputers, buses are generally categorized into internal buses, system buses, and external buses. The internal bus connects peripheral chips within the microcomputer to the processor for chip-level interconnection. The system bus connects plug-in boards to the system board within the microcomputer for board-level interconnection. The external bus connects the microcomputer to external devices. As a device, the microcomputer exchanges information and data with other equipment through this bus, enabling device-level interconnection. Furthermore, in a broad sense, computer communication methods can be divided into parallel communication and serial communication, with the corresponding communication buses referred to as parallel buses and serial buses. Parallel communication offers high speed and good real-time performance, but due to the large number of signal lines required, it is not suitable for miniaturized products. Although serial communication has a lower rate, it is simpler, more convenient, and more flexible in microprocessor circuits where data throughput is not substantial. Serial communication is generally classified into asynchronous mode and synchronous mode. With the development of microelectronics and computer technology, bus technology continues to evolve and improve, resulting in a wide variety of computer bus technologies, each with distinct characteristics.
EFFEKTA plug material
1) The material for female or male terminals shall be copper alloy, or plated copper alloy, nickel, or nickel alloy. [Exception: If the structure of the electrical appliance or apparatus permits, the female or male terminals may be plated steel sheet, or non-plated but corrosion-resistant alloy. 2) If formed female terminals or trimmed male terminals appear in the form of terminal strips, when the terminal strip is continuously fed into the processing tool, the terminals are curled and separated from the strip. In this case, the edge where the terminal connects to the strip does not need plating. The standard terminals used in temperature and thermal cycling tests shall be tin-plated steel sheet or corrosion-resistant steel. According to the Rockwell 30T hardness standard, their hardness shall be Rockwell hardness 68 ± 5. Exception: If the female terminal is only suitable for connecting male terminals made of copper alloy, then C26000 copper alloy standard terminals shall be used for testing. 2.3 According to the Rockwell 30T hardness standard, the hardness of standard terminals made of brass shall be 62 ± 7.
EFFEKTA plug main parameters
1) Rated Voltage: Rated voltage, also known as operating voltage, primarily depends on the insulation materials used in the connector and the spacing between contact pairs. Certain components or devices may fail to perform their intended functions when operated below their rated voltage. The rated voltage of a connector should effectively be understood as the maximum operating voltage recommended by the manufacturer. In principle, connectors can operate normally at voltages below the rated voltage. The author recommends selecting the rated voltage reasonably based on the connector's dielectric strength (withstand voltage) specifications, taking into account the application environment and safety level requirements. This means that for the same dielectric strength specification, different maximum operating voltages can be applied depending on the specific usage environment and safety requirements, which aligns better with practical operating conditions. 2) Rated Current: Also known as operating current. Similar to rated voltage, connectors generally operate normally when the current is below the rated current. During the connector design process, thermal design is employed to meet rated current requirements because current flowing through contact pairs generates heat due to conductor resistance and contact resistance. If the temperature rise exceeds a certain limit, it can damage the connector's insulation and cause softening of the contact pair surface plating, leading to failures. Therefore, limiting the rated current essentially means ensuring that the internal temperature rise of the connector does not exceed the designed specified value. A key consideration during selection is that for multi-core connectors, the rated current must be derated. This is particularly important in high-current applications. For example, for a 3.5mm contact pair, the rated current is generally specified as 50A, but for a 5-core configuration, it must be derated by 33%, meaning the rated current per core is only 38A. The greater the number of cores, the larger the derating factor. 3) Contact Resistance: Contact resistance refers to the resistance generated at the contact interface between two conductive contacts. Two issues should be noted during selection. First, the contact resistance specification of a connector actually refers to the contact pair resistance, which includes both the contact resistance and the conductor resistance of the contact pair. Since conductor resistance is typically small, the contact pair resistance is often referred to simply as contact resistance in many technical specifications. Second, in circuits handling small signals, attention must be paid to the conditions under which the specified contact resistance is tested. Oxide layers, oil stains, or other contaminants on the contact surfaces can create film resistance. As the film thickness increases, the resistance rises rapidly, turning the film into a poor conductor. However, this film layer can undergo mechanical breakdown under high contact pressure, or electrical breakdown under high voltage or high current. For some compact connectors designed with relatively low contact pressure, intended for use at only mA and mV levels, the film resistance may not break down easily, potentially affecting signal transmission. One of the contact resistance test methods specified in GB5095 "Basic Test Procedures and Measurement Methods for Electromechanical Components Used in Electrical Equipment," namely the "Contact Resistance - Millivolt Method," stipulates that to prevent breakdown of the insulating film on the contacts, the DC or AC peak open-circuit electromotive force of the test circuit shall not exceed 20mV, and the DC or AC test current shall not exceed 100mA. 4) Shielding: In modern electrical and electronic equipment, the increasing density of components and their interrelated functions impose strict limits on electromagnetic interference. Therefore, connectors are often enclosed in metal housings to prevent internal electromagnetic radiation or interference from external electromagnetic fields. At low frequencies, only magnetic materials provide significant shielding against magnetic fields. In such cases, there are specific requirements for the electrical continuity of the metal housing, which relates to the housing contact resistance.
Weidou Intelligent Technology specializes in selling German EFFEKTA connectors, EFFEKTA connectors, EFFEKTA interface modules, EFFEKTA terminal blocks, EFFEKTA bus interfaces, EFFEKTA bus modules, EFFEKTA communication modules, EFFEKTA fieldbus, EFFEKTA plug interfaces, EFFEKTA communication interfaces, EFFEKTA adapters, EFFEKTA output modules, EFFEKTA distributor converters, EFFEKTA plug buses, EFFEKTA expansion modules, EFFEKTA original imports from Germany. Welcome customers to inquire and order.






