German benning plug benning model benning price

German benning plug benning model benning price

benning plug is the public communication backbone for transmitting information between various functional components of a computer. It is a transmission bundle composed of wires. According to the types of information transmitted by the computer, the computer bus can be divided into data bus, address bus, and control bus, which are used to transmit data, data addresses, and control signals respectively. The bus is an internal structure; it is the common channel for cpu, memory, input, and output devices to transmit information. The various components of the host are connected via the bus, and external devices are connected to the bus through corresponding interface circuits, thereby

SKU
_P004499796
Category
phoenix connectors, telegartner plugs
Brand
benning
Tags
Connectors / Connector / Interface Module / Terminal Block / Bus Interface / Germany benning
benning plug is the public communication backbone for transmitting information between various functional components of a computer. It is a transmission bundle composed of wires. According to the types of information transmitted by the computer, the computer bus can be divided into data bus, address bus, and control bus, which are used to transmit data, data addresses, and control signals respectively. The bus is an internal structure; it is the common channel for cpu, memory, input, and output devices to transmit information. The various components of the host are connected via the bus, and external devices are connected to the bus through corresponding interface circuits, thereby forming the computer hardware system. In a computer system, the public path for transmitting information between various components is called the bus. Microcomputers connect various functional components using a bus structure.


benning plug principle


The bus is a shared data transmission device. Although multiple devices can be connected to the bus, typically only one pair of devices participates in data transmission at any given time. According to the form of information transmission, buses can be divided into parallel buses and serial buses. A parallel bus transmits n bits of binary information simultaneously using n transmission lines. Its characteristics include high transmission speed, but the system structure is more complex. It is used for connections between various components within a computer system. A serial bus shares a single transmission line for multi-bit binary information, with the bits passing through the bus in chronological order. Its characteristics include a simple structure, but its transmission speed is slower. The bus must have clear specifications: Bus timing protocols, meaning that certain timing rules must be followed when transmitting information on the bus, such as synchronous bus timing, asynchronous bus timing, and semi-synchronous bus timing. The physical characteristics of the bus, including the electrical characteristics of signals, power, and addresses, as well as the mechanical characteristics of wiring and connectors. Bus bandwidth is the maximum transmission rate achievable by the bus, and its unit is MB/S.


benning plug type


1) 232-C is a serial physical interface standard established by the American EIA (Electronic Industry Association). RS is the abbreviation for "Recommended Standard," 232 is the identification number, and C indicates the number of revisions. The RS-232-C bus standard has 25 signal lines, including a main channel and an auxiliary channel. In most cases, the main channel is primarily used. For general full-duplex communication, only a few signal lines are required, such as one transmit line, one receive line, and one ground line. The RS-232-C standard specifies that the driver allows a capacitive load of 2500pF. The communication distance is limited by this capacitance. For example, when using a communication cable with 150pF/m, the maximum communication distance is 15m; if the capacitance per meter of cable decreases, the communication distance can increase. Another reason for the short transmission distance is that RS-232 uses single-ended signal transmission, which suffers from common ground noise and cannot suppress common-mode interference. Therefore, it is generally used for communication within 20m. 2) RS-485 bus: When the required communication distance ranges from tens of meters to over a kilometer, the RS-485 serial bus standard is widely adopted. RS-485 uses balanced transmission and differential reception, thus having the ability to suppress common-mode interference. Additionally, the bus transceiver has high sensitivity and can detect voltages as low as 200mV, allowing transmission signals to be recovered even beyond a kilometer. RS-485 operates in half-duplex mode, meaning only one point can be in the transmitting state at any time. Therefore, the transmitting circuit must be controlled by an enable signal. RS-485 is very convenient for multi-point interconnection, saving many signal lines. Applying RS-485 allows networking to form distributed systems, permitting up to 32 drivers and 32 receivers to be connected in parallel.


benning plug safety parameters


1) Insulation resistance: Insulation resistance refers to the resistance value presented by leakage current generated on or within the surface of the insulating part of a connector when voltage is applied. It is mainly influenced by factors such as insulation material, temperature, humidity, and contamination. The insulation resistance values provided in connector samples are generally indicators under standard atmospheric conditions. Under certain environmental conditions, the insulation resistance value will decrease to varying degrees. Additionally, pay attention to the test voltage value for insulation resistance. Based on insulation resistance (MΩ) = voltage applied to the insulator (V) / leakage current (μA), applying different voltages yields different results. In connector tests, the applied voltages generally have three levels: 10V, 100V, and 500V. 2) Rated voltage: Dielectric strength is the critical voltage that the mutually insulating parts of contact pairs, or the insulating parts and ground, can withstand within a specified time without breakdown, exceeding the rated voltage. It is mainly influenced by contact pair spacing, creepage distance, geometric shape, insulator material, ambient temperature and humidity, and atmospheric pressure. 3) Mechanical life: The mechanical life of a connector refers to its mating cycle life, typically specified as 500 to 1000 cycles. When reaching this specified mechanical life, the connector's contact resistance, insulation resistance, and dielectric strength indicators should not exceed specified values. Strictly speaking, mechanical life is related to time; using 500 cycles over 10 years is obviously different from using 500 cycles over 1 years. First, select the number of contact pairs based on circuit requirements, while considering the connector's volume and total separation force. A higher number of contact pairs naturally results in larger volume and relatively greater total separation force. In cases with high reliability requirements where volume permits, two contact pairs can be connected in parallel to improve connection reliability. In connector plugs and sockets, pins (male contacts) and sockets (female contacts) are generally interchangeable. In actual use, selection can be made based on the energized status at both ends of the plug and socket. For example, if the socket needs to remain energized, choose a socket equipped with female contacts, as the energized contacts are embedded in the insulator, making them less accessible to human touch and relatively safer. Mainly consider the electrical continuity of contact pairs during vibration, shock, and collision under specified frequency and acceleration conditions. Contact pairs may experience instantaneous open circuits under such dynamic stress. Specified instantaneous interruption times generally include 1μs, 10μs, 100μs, 1ms, and 10ms. Note how to judge instantaneous interruption faults in contact pairs. Currently, it is considered that a fault in the closed contact pair (contact) occurs when the voltage drop across its ends exceeds 50% of the power source electromotive force. That is, there are two conditions for judging instantaneous interruption: duration and voltage drop, both of which are indispensable. Connectors generally consist of plugs and sockets, where the plug is also called a free-end connector, and the socket is also called a fixed connector. Circuit connection and disconnection are achieved through the mating and separation of plugs and sockets, resulting in various connection methods for plugs and sockets. For circular connectors, the main methods are threaded coupling, bayonet coupling, and push-pull (ball-lock) coupling. Threaded coupling is the most common, offering advantages such as simple processing technology, low manufacturing cost, and wide applicability, but it has a slower connection speed and is not suitable for frequent mating/unmating and rapid connection scenarios. Bayonet coupling has a faster connection speed due to the longer lead of its three bayonet slots, but it is more complex to manufacture and has a higher cost. Push-pull coupling is the fastest among the three connection methods; it does not require rotational motion, achieving connection, separation, and locking through linear motion only. As it belongs to the straight push-pull connection method, it is only suitable for connectors with low total separation force. It is generally more common in small connectors.



Weidou Intelligent Technology professionally sells German benning connectors, benning connectors, benning interface modules, benning terminal blocks, benning bus interfaces, benning bus modules, benning communication modules, benning fieldbus, benning plug interfaces, benning communication interfaces, benning adapters, benning output modules, benning distributor converters, benning plug buses, benning expansion modules, benning original German imports. Welcome customers to inquire and order.