Weidou Intelligent Technology (Shanghai) Co., Ltd.
中文
WDUTECH industrial automation products and services
Categories and filters

Home/Products/ phoenix connectors, telegartner plugs

German AQ-Trafo AB plug AQ-Trafo AB model AQ-Trafo AB price

German AQ-Trafo AB plug AQ-Trafo AB model AQ-Trafo AB price

AQ-Trafo AB plug is the public communication backbone for transmitting information between various functional components of a computer. It is a transmission bundle composed of wires. According to the types of information transmitted by the computer, the computer bus can be divided into data bus, address bus, and control bus, which are used to transmit data, data addresses, and control signals, respectively. The bus is an internal structure; it is the common channel for cpu, memory, input, and output devices to transmit information. Various components of the host are connected via the bus, and external devices are connected to the bus through corresponding interface circuits.

SKU
_P004499763
Category
phoenix connectors, telegartner plugs
Tags
Connectors / Connector / Interface Module / Terminal Block / Bus Interface / Germany AQ-Trafo AB
AQ-Trafo AB plug is the public communication backbone for transmitting information between various functional components of a computer. It is a transmission bundle composed of wires. According to the types of information transmitted by the computer, the computer bus can be divided into data bus, address bus, and control bus, which are used to transmit data, data addresses, and control signals, respectively. The bus is an internal structure; it is the common channel for cpu, memory, input, and output devices to transmit information. Various components of the host are connected via the bus, and external devices are connected to the bus through corresponding interface circuits, thereby forming the computer hardware system. In a computer system, the public path for transmitting information between various components is called the bus. Microcomputers use a bus structure to connect various functional components.


AQ-Trafo AB plug working principle


If the motherboard (Mother Board) is a city, then the bus is like the public buses (bus) in the city, capable of transmitting bits (bit) that operate back and forth along fixed routes. These lines can only be responsible for transmitting one bit at a time. Therefore, multiple lines must be used simultaneously to transmit more data. The number of data items that the bus can transmit simultaneously is called the width (width), measured in bits. The greater the bus width, the better the transmission performance. The bus bandwidth (i.e., the total amount of data that can be transmitted per unit time) is: Bus Bandwidth = Frequency x Width (Bytes/sec). When the bus is idle (other devices are connected to the bus in a high-impedance state) and a device needs to communicate with a target device, the initiating device drives the bus, issuing address and data. Other devices connected to the bus in a high-impedance state, upon receiving (or being able to receive) address information matching their own, accept the data on the bus. After the sending device completes communication, it releases the bus (output changes to high-impedance state).


AQ-Trafo AB plug features


1) Physical characteristics: Physical characteristics, also known as mechanical characteristics, refer to some characteristics exhibited by components on the bus during physical connection, such as the geometric dimensions, shape, number of pins, and arrangement order of plugs and sockets. 2) Functional characteristics: Functional characteristics refer to the function of each signal line. For example, the address bus is used to represent address codes. The data bus is used to represent transmitted data. The control bus represents commands, states, etc., for operations on the bus. 3) Electrical characteristics: Electrical characteristics refer to the signal direction on each signal line and the voltage level range representing valid signals. Typically, signals issued by the master device (such as CPU) are called output signals (OUT), and signals sent into the master device are called input signals (IN). Typically, for data and address signals, a high level is defined as logic 1 and a low level as logic 0. There is no customary convention for control signals; for example, WE indicates active-low, and Ready indicates active-high. There is no unified regulation for the high-level and low-level voltage ranges of different buses; they are usually consistent with TTL. 4) Timing characteristics: Timing characteristics, also known as logical characteristics, refer to when signals on each signal line are valid during bus operation. Through this agreement on the timing relationship of valid signals, correct bus operation is ensured. To improve the scalability of computers and the universality of components and devices, apart from on-chip buses, various components or devices adopt standardized forms to connect to the bus and implement information transmission on the bus in a standardized manner. These standardized connection forms and operation methods of the bus are collectively referred to as bus standards. Examples include ISA, PCI, and USB bus standards. Correspondingly, buses adopting these standards are ISA bus, PCI bus, and USB bus.


AQ-Trafo AB plug safety parameters


1) Insulation resistance: Insulation resistance refers to the resistance value exhibited due to leakage current generated within or on the surface of the insulating part when voltage is applied to the insulating part of the connector. It is mainly affected by factors such as insulation material, temperature, humidity, and contamination. The insulation resistance values provided in connector catalogs are generally indicator values under standard atmospheric conditions; under certain environmental conditions, the insulation resistance value will decrease to varying degrees. Additionally, pay attention to the test voltage value for insulation resistance. According to insulation resistance (MΩ) = voltage applied to the insulator (V) / leakage current (μA), applying different voltages yields different results. In connector testing, the applied voltages generally have three levels: 10V, 100V, and 500V. 2) Rated voltage: Dielectric strength is the critical voltage that the mutually insulating parts of a contact pair, or the insulating part and ground, can withstand without breakdown within a specified time, which is higher than the rated voltage. It is mainly affected by contact pair spacing, creepage distance, geometric shape, insulator material, as well as environmental temperature, humidity, and atmospheric pressure. 3) Mechanical life: The mechanical life of a connector refers to its mating cycle life, typically specified as 500 to 1000 cycles. When this specified mechanical life is reached, indicators such as contact resistance, insulation resistance, and dielectric strength of the connector should not exceed the specified values. Strictly speaking, mechanical life is related to time; using 500 cycles over 10 years is obviously different from using 500 cycles over 1 years. First, select the number of contact pairs according to circuit requirements, while considering the connector's volume and the total separation force. A larger number of contact pairs naturally results in a larger volume and a relatively greater total separation force. In cases with high reliability requirements where volume permits, two contact pairs can be connected in parallel to improve connection reliability. In connector plugs and sockets, pins (male contacts) and sockets (female contacts) are generally interchangeable in assembly. In actual use, selection can be made based on the live status at both ends of the plug and socket. For example, if the socket needs to remain live, choose a socket equipped with female contacts, because in such sockets, the live contacts are embedded in the insulator, making them less accessible to human touch and relatively safer. Mainly consider the electrical continuity of contact pairs during vibration, shock, and collision under specified frequency and acceleration conditions. Contact pairs may experience instantaneous open circuits under such dynamic stress. The specified instantaneous interruption times are generally 1μs, 10μs, 100μs, 1ms, and 10ms. Note how to judge instantaneous interruption faults in contact pairs. It is currently considered that a fault in a closed contact pair (contact) can be determined when the voltage drop across both ends exceeds 50% of the power source electromotive force. In other words, there are two conditions for judging instantaneous interruption: duration and voltage drop, both of which are indispensable. Connectors generally consist of plugs and sockets, where the plug is also called a free-end connector, and the socket is also called a fixed connector. Circuit connection and disconnection are achieved through the mating and separation of plugs and sockets, resulting in various connection methods for plugs and sockets. For circular connectors, the main methods are threaded coupling, bayonet coupling, and push-pull (ball-lock) coupling. Among these, threaded coupling is the most common, offering advantages such as simple processing technology, low manufacturing cost, and wide applicability, but it has a slower connection speed and is not suitable for occasions requiring frequent mating/unmating and rapid connections. Bayonet coupling has a faster connection speed due to the longer lead of its three bayonet slots, but it is more complex to manufacture and has a higher cost. Push-pull (ball-lock) coupling is the fastest among the three connection methods; it does not require rotational motion, only linear motion, to achieve connection, separation, and locking functions. As it belongs to the straight push-pull connection method, it is only suitable for connectors with low total separation force. It is generally more common in small-sized connectors.



Weidou Intelligent Technology specializes in selling German AQ-Trafo AB connectors, AQ-Trafo AB connectors, AQ-Trafo AB interface modules, AQ-Trafo AB terminal blocks, AQ-Trafo AB bus interfaces, AQ-Trafo AB bus modules, AQ-Trafo AB communication modules, AQ-Trafo AB fieldbus, AQ-Trafo AB plug interfaces, AQ-Trafo AB communication interfaces, AQ-Trafo AB adapters, AQ-Trafo AB output modules, AQ-Trafo AB distributor converters, AQ-Trafo AB plug bus, AQ-Trafo AB expansion modules, AQ-Trafo AB original German imports. Welcome customers to inquire and order.





Recommended products