Weidou Intelligent Technology (Shanghai) Co., Ltd.
中文
WDUTECH industrial automation products and services
Categories and filters

Home/Products/ hoffmann tools, emuge gauges

German OCHSENKOPF tools OCHSENKOPF models OCHSENKOPF prices

German OCHSENKOPF tools OCHSENKOPF models OCHSENKOPF prices

OCHSENKOPF tools are any functional tools connected to the edge (joint) of a robot. This may include robot grippers, robot tool changers, robot collision sensors, robot rotary unions, robot pressure tools, compliance devices, robot spray guns, robot deburring tools, robot arc welding torches, robot electric welding torches, etc. Robot end-effectors are generally considered peripheral equipment, accessories, robot tools, or arm-end tools (EOA). Industrial loading and unloading machines

SKU
_P004495804
Category
hoffmann tools, emuge gauges
Tags
Hand Tools / Workpiece Fixture / Hydraulic Tools / Power Tools / Pneumatic Tools / Germany OCHSENKOPF
OCHSENKOPF tools are any functional tools connected to the edge (joint) of a robot. This may include robot grippers, robot tool changers, robot collision sensors, robot rotary unions, robot pressure tools, compliance devices, robot spray guns, robot deburring tools, robot arc welding torches, robot electric welding torches, etc. Robot end-effectors are generally considered peripheral equipment, accessories, robot tools, or arm-end tools (EOA). Mechanical clamping end-effectors used in industrial loading and unloading robots are mostly two-finger claw types. Classified by finger motion, they can be divided into translational and rotational types. Classified by mechanical clamping method, they can be divided into external clamping and internal expanding types. Classified by mechanical structural characteristics, they can be divided into electric (electromagnetic), hydraulic, and pneumatic types, as well as their combinations.


OCHSENKOPF tool applications and usage


The electric hydraulic oil pump can serve as the hydraulic pump for various hydraulic instruments. When equipped with other hydraulic tools, the electric hydraulic oil pump can perform lifting, pressing, pipe bending, bar bending, straightening, shearing, assembly, disassembly, and other tasks. It reduces labor intensity and improves work efficiency. During use, open the air release nut, open the switch on the oil collection block, connect the power supply, and attach the quick connector to the quick coupling of the corresponding hydraulic instrument. Press the power switch; after the motor runs for 1-2 minutes, close the switch to the boost position. At this point, the output hydraulic oil will perform various tasks, with pressure self-boosting as the load increases until 63MPA. After work is completed, open the switch to relieve pressure. Once the hydraulic oil has returned, remove the quick connector, tighten the air release nut, unplug the power cord, and close the switch.


OCHSENKOPF tool selection


1) Distinguish between household and professional use as needed. Most power tools are designed for professionals. When purchasing, distinguish between professional and general household tools. The difference usually lies in power; professional tools have higher power to help professionals reduce workload. General household tools involve smaller projects and less workload, so high input power is not required. 2) The tool's outer packaging should have clear patterns, no damage, a sturdy plastic box, and durable latches. 3) The tool's appearance should have uniform color. Plastic parts should have no visible flow marks or indentations, scratches, or impact marks. Assembly misalignment between housing parts should be ≤ 0.5mm. Aluminum casting coatings should be smooth, aesthetically pleasing, and undamaged. The entire unit should be free of oil and stains. When held, the switch handle should be flat. The cable length should generally be no less than 2 meters. 4) The nameplate parameters must match those on the CCC certificate. The manual should include the manufacturer's and factory's detailed address and contact information. The nameplate or certificate of conformity should include a traceable batch number. 5) Hold the tool, connect the power, and frequently operate the switch to start the tool repeatedly. Observe whether the switch's on/off function is reliable. Simultaneously observe nearby TVs and fluorescent lights for abnormalities to confirm the tool is equipped with an effective radio interference suppressor. 6) Run the tool under power for one minute. While holding it during operation, there should be no noticeable abnormal vibration. Observe the commutation sparks; they should not exceed level 3/2. Generally, looking into the air inlet, there should be no obvious arcing on the commutator surface. There should be no abnormal noise during operation.


OCHSENKOPF tool usage


1) Inspect carefully before use. The appearance should be undamaged, the switch should move flexibly without sticking, and the power cord and tool housing should be intact. Use a 500V megohmmeter to measure the insulation resistance between the winding and the housing; it must not be lower than O.5 megohms. See the attached table for insulation resistance values. 2) Handheld power tools with metal housings must have a reliable protective ground wire. The power cord should be a multi-core soft rubber-sheathed cable, with the ground protection wire securely connected at both ends. 3) Handheld power tools should be used by dedicated personnel with appropriate professional knowledge. Strictly adhere to relevant safety operating procedures during use. 4) Before use, check that related electrical and mechanical protection devices are intact and functioning normally. Also ensure rotating parts move flexibly without sticking. 5) When using Class I handheld power tools, users must wear prescribed protective equipment and set up qualified protective gear. Take appropriate anti-electric shock safety measures as required, such as installing a residual current device (RCD) in the power circuit, or having the user wear insulating gloves, insulating shoes, or stand on an insulating mat. When using Class II handheld power tools in damp, confined spaces, install a leakage switch with an operating current of less than 1.5mA and an action time of ≤ 0.1 seconds. The leakage switch should be placed inside the container and monitored by dedicated personnel. 6) Occupational hazards of using handheld power tools. Arm vibration disease caused by long-term hand-transmitted vibration work was listed as one of China's statutory occupational diseases in 1957, also known as local vibration disease, typically manifested as episodic white finger.



Weidou Intelligent Technology professionally sells German OCHSENKOPF workpiece clamps, OCHSENKOPF hydraulic tools, OCHSENKOPF power tools, OCHSENKOPF pneumatic tools, OCHSENKOPF hand tools, OCHSENKOPF electronic tools, OCHSENKOPF welding tools, OCHSENKOPF pipe tools, OCHSENKOPF explosion-proof tools, OCHSENKOPF electrical power tools, OCHSENKOPF automotive maintenance tools, OCHSENKOPF fastening tools, OCHSENKOPF cutting tools, OCHSENKOPF striking tools, OCHSENKOPF grinding tools. OCHSENKOPF original German imports. Welcome inquiries and orders from customers.





Recommended products