German Ammer ST tools, Ammer ST models, Ammer ST prices
Ammer ST tools integrate hydraulic systems with conventional tools into a unified assembly. They convert powerful hydraulic power into mechanical motions such as reciprocating linear motion, rotary motion, and orbital motion. A complete hydraulic tool system consists of five components: power elements, actuating elements, control elements, auxiliary elements, and hydraulic oil. Hydraulic tools include: hydraulic wrenches, electric pumps dedicated to hydraulic wrenches, hydraulic jacks, hydraulic bolt tensioners, hydraulic flange spreaders, hydraulic nut splitters, hydraulic pullers, etc. Hydraulic tools offer high efficiency and convenience.
- SKU
- _P004495339
- Category
- hoffmann tools, emuge gauges
- Brand
- Ammer ST
- Tags
- Hand Tools / Workpiece Fixture / Hydraulic Tools / Power Tools / Pneumatic Tools / Germany Ammer ST
Ammer ST tool applications and usage
The electric hydraulic oil pump can serve as the hydraulic pump for various hydraulic devices. When paired with other hydraulic tools, the electric hydraulic oil pump enables tasks such as lifting, pressing, pipe bending, bar bending, straightening, shearing, assembly, and disassembly. It reduces labor intensity and improves work efficiency. During use, open the air release nut, open the valve on the oil collection block, connect the power supply, and attach the quick coupler to the quick connector on the corresponding hydraulic device. Press the power switch; after the motor runs for 1-2 minutes, close the switch to set it to the pressure-boosting state. At this point, the output hydraulic oil will perform various tasks, with pressure self-boosting as the load increases until reaching 63MPA. After work is completed, open the valve to relieve pressure. Once the hydraulic oil has returned, remove the quick coupler, tighten the air release nut, unplug the power cord, and close the valve.
Ammer ST tool usage
1) Select the appropriate saw blade for the workpiece; for example, use 14 teeth per inch for cutting solid or thick soft metals; use 18 teeth per inch for tool steel, iron pipes, and hard metals; and 24 teeth per inch are suitable for cutting metal sheets, metal pipes, and thin iron bars. 2) Push the saw forward, and lift it slightly when pulling back. 3) Select a wrench of appropriate size according to the nature of the work. 4) When using an adjustable wrench, apply force toward the fixed jaw, never toward the adjustable jaw. 5) If the wrench jaws are worn or slip during use, do not continue using them to prevent slipping. 6) Do not use a wrench as a hammer for striking. 5) Do not fit a pipe over the handle end of a wrench to increase torque. 7) Press the inner side of the first leg of the square against the edge of the wooden board, and draw along the inner side of the second leg with a pencil to mark a perpendicular line. 8) Select the appropriate screwdriver based on the size and shape of the screw head slot. 9) Do not strike the screwdriver handle with a hammer; replace handles that are damaged immediately. 10) Do not use a screwdriver as a chisel or lever. 11) Use an electrician's screwdriver to test current; do not use a standard screwdriver to test high voltage. 12) Do not grind the screwdriver tip to avoid damaging the hardened surface. 13) Do not place screwdrivers in shirt or trouser pockets to prevent injury from collisions or falls.
Ammer ST tool usage
1) Inspect carefully before use: ensure there is no external damage, the switch operates flexibly without sticking, and the power cord and tool housing are intact. Use a 500V megohmmeter to measure the insulation resistance between the winding and the housing; it must not be less than O.5 megohms. See the attached table for insulation resistance values. 2) Handheld electric tools with metal housings must have a reliable protective grounding wire. The power cord shall be a multi-core soft rubber-sheathed cable, and the grounding protection wire must be securely connected at both ends. 3) Handheld electric tools should be operated by dedicated personnel with appropriate professional knowledge. Strictly adhere to relevant safety operating procedures during use. 4) Before use, check whether the related electrical and mechanical protective devices are intact and functioning normally. Also ensure that rotating parts move flexibly without sticking. 5) When using Class I handheld electric tools, operators must wear prescribed protective equipment and use qualified protective gear. Take corresponding anti-electric shock safety measures as required, such as installing residual current devices (RCDs) in the power circuit, or having the operator wear insulating gloves, insulating shoes, or stand on an insulating mat. When using Class II handheld electric tools in damp and confined spaces, install a residual current circuit breaker (RCCB) with an operating current of less than 1.5mA and an operating time of less than or equal to 0.1 seconds. The RCCB should be placed inside the container and monitored by dedicated personnel. 6) Occupational hazards of using handheld electric tools. Arm vibration disease caused by long-term hand-transmitted vibration work was listed as one of China's statutory occupational diseases as early as 1957, also known as local vibration disease, typically manifesting as episodic white finger.
Weidou Intelligent Technology specializes in selling German Ammer ST workholding fixtures, Ammer ST hydraulic tools, Ammer ST power tools, Ammer ST pneumatic tools, Ammer ST hand tools, Ammer ST electronic tools, Ammer ST welding tools, Ammer ST piping tools, Ammer ST explosion-proof tools, Ammer ST electrical power tools, Ammer ST automotive maintenance tools, Ammer ST fastening tools, Ammer ST cutting tools, Ammer ST striking tools, Ammer ST grinding tools. Ammer ST products are original imports from Germany. Customers are welcome to inquire and order.