German MULTIDRONET SL sensor, MULTIDRONET SL model, MULTIDRONET SL price
MULTIDRONET SL sensor for liquid level measurement using pressure sensors. The static pressure submersible level transmitter (level gauge) is based on the principle that the static pressure of the measured liquid is proportional to its height. It uses advanced foreign isolated diffused silicon sensitive elements or ceramic capacitive pressure sensitive sensors to convert static pressure into electrical signals, which are then converted into standard electrical signals (typically 4 to 20mA/15VDC) after temperature compensation and linear correction. MULTIDRONET SL sensor classification: Load cells are classified by conversion method into photoelectric,
- SKU
- _P004480457
- Category
- balluff sensor turck sensor in stock
- Brand
- MULTIDRONET SL
- Tags
- Photoelectric Sensor / German sensors / Inductive Sensor / Measurement Sensors / MULTIDRONET SL sensor
MULTIDRONET SL sensor classification
Load cells are classified into 8 types by conversion method, including photoelectric, hydraulic, electromagnetic force, capacitive, magnetic pole variation, vibratory, gyroscopic, and resistance strain gauge types, with resistance strain gauge being the most widely used. 1) Photoelectric type: Includes grating and code disk types. Grating sensors use Moiré fringes formed by gratings to convert angular displacement into photoelectric signals. There are two gratings: one fixed grating and one moving grating mounted on the dial shaft. The object being weighed on the load platform rotates the dial shaft through a force transmission lever system, driving the moving grating to rotate and causing the Moiré fringes to move. By using phototubes, conversion circuits, and display instruments, the number of moved Moiré fringes can be calculated to determine the angle of grating rotation, thereby determining and reading the mass of the object. Code disk sensors: A code disk (symbol plate) is a piece of transparent glass mounted on the dial shaft, featuring black and white codes arranged according to a specific encoding method. When the object on the load platform rotates the dial shaft via the force transmission lever, the code disk also rotates by a certain angle. Photocells receive light signals passing through the code disk and convert them into electrical signals, which are then digitally processed by the circuit, finally displaying the digital value representing the measured mass on the display. Photoelectric sensors were mainly used in electromechanical combination scales. 2) Hydraulic type: Under the action of the gravity P of the measured object, the pressure of the hydraulic oil increases, with the degree of increase proportional to P. By measuring the increased pressure value, the mass of the object can be determined. Hydraulic sensors have a simple and robust structure with a large measurement range, but accuracy generally does not exceed 1/100. 3) Capacitive type: It operates based on the direct proportional relationship between the oscillation frequency f of the capacitor oscillator circuit and the distance d between the plates. There are two plates, one fixed and the other movable. When the object is loaded onto the load platform, the leaf spring deflects, changing the distance between the two plates, which in turn changes the oscillation frequency of the circuit. By measuring the change in frequency, the mass of the object on the load platform can be determined. Capacitive sensors consume little power, have low cost, and an accuracy of 1/200 to 1/500.
MULTIDRONET SL sensor features
Resistors, inductors, and capacitors are the three major types of passive components in electronics. A capacitive sensor is a sensor that converts changes in the measured quantity into changes in capacitance; it is essentially a capacitor with variable parameters. Capacitive sensors have the following advantages: high impedance, low power, requiring only very low input energy. They can achieve large changes, resulting in high signal-to-noise ratio and system stability. Fast dynamic response, with operating frequencies up to several megahertz, suitable for non-b contact measurement, regardless of whether the measured object is a conductor or semiconductor. Simple structure, strong adaptability, capable of working in harsh environments such as high/low temperatures and strong radiation, with wide applications. With the development of electronic technology and computer technology, the disadvantages of capacitive sensors, such as susceptibility to interference and distributed capacitance, have been continuously overcome. Additionally, capacitive grid displacement sensors and integrated capacitive sensors have been developed. Therefore, they are widely used in non-electrical quantity measurement and automatic detection, capable of measuring parameters such as pressure, displacement, speed, acceleration, Angle, thickness, liquid level, humidity, vibration, and component content. Capacitive sensors have good development prospects.
MULTIDRONET SL sensor installation precautions
1) Handle load cells with care, especially small-capacity sensors with aluminum alloy elastic bodies. Any impact or drop caused by vibration is likely to cause significant output errors.
2) When designing the loading device and during installation, ensure that the line of action of the loading force coincides with the force axis of the load cell to minimize the effects of inclined and eccentric loads.
3) For horizontal adjustment: If using a load cell, adjust the installation plane of its base with a level until it is horizontal. If multiple sensors are used for simultaneous measurement, their base installation surfaces should be kept as level as possible to ensure that the force borne by each sensor is basically consistent.
4) Determine the rated load of the sensor used based on the load cell capacity selection specified in its instructions.
5) To prevent chemical corrosion, apply Vaseline to the outer surface of the load cell during installation. Avoid use in locations with direct sunlight exposure and drastic environmental temperature changes.
6) Connect bypasses made of copper braided wire to both ends of the load cell loading device.
7) Do not extend the cable yourself. If extension is absolutely necessary, solder at the joint and add moisture-proof sealant.
8) It is best to use baffles around the load cell to cover it. This prevents debris from falling into the moving parts of the sensor, affecting its measurement accuracy.
9) Keep the sensor cable away from high-power power lines or places with pulse waves. If avoidance is impossible, run the load cell cable separately through an iron pipe and shorten the connection distance as much as possible.
10) Determine the rated load of the sensor used based on the load cell capacity selection specified in its instructions. Although load cells have a certain overload capacity, avoid such situations during installation and use. Even short-term overloading may cause permanent damage to the sensor.
11) For high-precision applications, allow the load cell and instrument to warm up for 30 minutes before use.
Weidou Intelligent Technology specializes in selling German MULTIDRONET SL sensors, MULTIDRONET SL proximity sensors, MULTIDRONET SL distance sensors, MULTIDRONET SL vision sensors, MULTIDRONET SL displacement sensors, MULTIDRONET SL load cells, MULTIDRONET SL speed sensors, MULTIDRONET SL photoelectric sensors, MULTIDRONET SL position sensors, MULTIDRONET SL angle sensors, MULTIDRONET SL tactile sensors, MULTIDRONET SL temperature sensors, MULTIDRONET SL pressure sensors, MULTIDRONET SL flow sensors, MULTIDRONET SL level sensors, MULTIDRONET SL motion sensors, MULTIDRONET SL process sensors. Original German imports. Welcome inquiries and orders from users.