Weidou Intelligent Technology (Shanghai) Co., Ltd.
WDUTECH industrial automation products and services
Categories and filters

Home/Products/ balluff sensor turck sensor in stock

German ERYIGIT MEDICAL sensor ERYIGIT MEDICAL model ERYIGIT MEDICAL price

German ERYIGIT MEDICAL sensor ERYIGIT MEDICAL model ERYIGIT MEDICAL price

ERYIGIT MEDICAL sensor is a device capable of sensing the approach of an object. It utilizes the sensitivity of a displacement sensor to approaching objects to detect proximity and output corresponding switching signals; therefore, proximity sensors are often referred to as proximity switches. It is a general term for sensors designed to replace contact-based detection methods such as switches, with the aim of non-contact detection of the target. It can detect the movement and presence of objects and convert this information into electrical signals. ERYIGIT MEDICAL sensor classification 1) Potentiometer

SKU
_P004479873
Category
balluff sensor turck sensor in stock
Tags
Photoelectric Sensor / German sensors / Inductive Sensor / Measurement Sensors / ERYIGIT MEDICAL sensor
ERYIGIT MEDICAL sensor is a device capable of sensing the approach of an object. It utilizes the sensitivity of a displacement sensor to approaching objects to detect proximity and output corresponding switching signals; therefore, proximity sensors are often referred to as proximity switches. It is a general term for sensors designed to replace contact-based detection methods such as switches, with the aim of non-contact detection of the target. It can detect the movement and presence of objects and convert this information into electrical signals.


ERYIGIT MEDICAL sensor classification


1) Potentiometric displacement sensors convert mechanical displacement into resistance or voltage outputs that have a linear or arbitrary functional relationship with the displacement. Standard linear potentiometers and rotary potentiometers can be used as linear displacement and angular displacement sensors, respectively. However, potentiometers designed for displacement measurement require a defined relationship between displacement change and resistance change. The movable wiper of the potentiometric displacement sensor is connected to the measured object. The displacement of the object causes a resistance change at the moving end of the potentiometer. The magnitude of the resistance change reflects the magnitude of the displacement, while an increase or decrease in resistance indicates the direction of displacement. Typically, a supply voltage is applied to the potentiometer to convert the resistance change into a voltage output. In wire-wound potentiometers, the resistance changes in steps corresponding to the turn-to-turn resistance as the wiper moves, resulting in a stepped output characteristic. If such a displacement sensor is used as a displacement feedback element in a servo system, excessive step voltages can cause system oscillation. Therefore, the resistance per turn should be minimized during potentiometer manufacturing. Another major disadvantage of potentiometric sensors is their susceptibility to wear. Their advantages include simple structure, large output signal, ease of use, and low cost. 2) Magnetostrictive displacement sensors precisely measure the actual displacement of the detected product by non-contactively detecting the absolute position of a moving magnetic ring. The high precision and high reliability of these sensors have been widely demonstrated in thousands of practical applications. Since the moving magnetic ring, which determines the position, does not come into direct contact with the sensitive element, the sensor can be used in extremely harsh industrial environments and is not easily affected by oil stains, solutions, dust, or other contaminants. The IP protection rating is above IP67. Furthermore, the sensor uses advanced materials and electronic processing technology, allowing it to operate in high-temperature, high-pressure, and high-vibration environments. The sensor output signal is an absolute displacement value; even if power is interrupted and restored, data is not lost, and re-zeroing is not required. Since the sensitive element is non-contact, repeated detection does not cause any wear to the sensor, significantly improving detection reliability and service life. Magnetostrictive displacement sensors accurately measure position based on the magnetostrictive principle, generating a strain pulse signal through the intersection of two different magnetic fields. The measuring element is a waveguide, with the sensitive element inside made of special magnetostrictive material. The measurement process involves generating a current pulse in the sensor's electronics chamber, which travels through the waveguide, creating a circular magnetic field around it. When this magnetic field intersects with the magnetic field generated by the moving magnetic ring sleeved on the waveguide (which changes with position), a strain mechanical wave pulse signal is generated within the waveguide due to the magnetostrictive effect. This strain mechanical wave pulse signal travels at a fixed speed of sound and is quickly detected by the electronics chamber. Since the transmission time of this strain mechanical wave pulse signal within the waveguide is proportional to the distance between the moving magnetic ring and the electronics chamber, measuring the time allows for highly precise determination of this distance. Because the output signal is a true absolute value, rather than a proportional or amplified signal, there is no signal drift or value variation, and periodic recalibration is not required. Magnetostrictive displacement sensors are high-precision, long-stroke absolute position measurement displacement sensors manufactured based on the magnetostrictive principle. They employ a non-contact measurement method; since the moving magnetic ring used for measurement does not directly contact the sensor itself, friction and wear are avoided, resulting in long service life, strong environmental adaptability, high reliability, good safety, and ease of integration into automated systems. They can operate normally even in harsh industrial environments. Additionally, they can withstand high temperatures, high pressures, and strong vibrations, and are now widely used in the measurement and control of mechanical displacement.


ERYIGIT MEDICAL sensor working principle


Magnetostrictive displacement (level) sensors accurately measure position based on the magnetostrictive principle, generating a strain pulse signal through the intersection of two different magnetic fields. The measuring element is a waveguide, with the sensitive element inside made of special magnetostrictive material. The measurement process involves generating a current pulse in the sensor's electronics chamber, which travels through the waveguide, creating a circular magnetic field around it. When this magnetic field intersects with the magnetic field generated by the moving magnetic ring sleeved on the waveguide (which changes with position), a strain mechanical wave pulse signal is generated within the waveguide due to the magnetostrictive effect. This strain mechanical wave pulse signal travels at a fixed speed of sound and is quickly detected by the electronics chamber. Since the transmission time of this strain mechanical wave pulse signal within the waveguide is proportional to the distance between the moving magnetic ring and the electronics chamber, measuring the time allows for highly precise determination of this distance. Because the output signal is a true absolute value, rather than a proportional or amplified signal, there is no signal drift or value variation, and periodic recalibration is not required.


ERYIGIT MEDICAL sensor application areas


Widely used for level measurement and control in various liquid tanks in the petroleum, chemical, water conservancy, pharmaceutical, food, and beverage industries, as well as in aerospace refueling systems, automotive refueling systems, diesel refueling systems, various hydraulic tanks, hydrological monitoring, and water treatment. Magnetostrictive displacement sensors are high-precision, long-stroke absolute position measurement displacement sensors manufactured based on the magnetostrictive principle. They employ an internal non-contact measurement method; since the moving magnetic ring used for measurement does not directly contact the sensor itself, friction and wear are avoided, resulting in long service life, strong environmental adaptability, high reliability, good safety, and ease of integration into automated systems. They can operate normally even in harsh industrial environments (such as those prone to oil stains, dust, or other contamination) [01]. Additionally, they can withstand high temperatures, high pressures, and strong vibrations, and are now widely used in the measurement and control of mechanical displacement. Their stroke can reach 3 meters or longer, with a nominal accuracy of 0.05% F·S. For sensors with a stroke of 1 meters or more, the accuracy can reach 0.02% F, S, and repeatability can reach 0.002% F·S. Therefore, they are widely used in the petrochemical, aerospace, electric power, and water conservancy industries.



Weidou Intelligent Technology specializes in selling German ERYIGIT MEDICAL sensors, ERYIGIT MEDICAL proximity sensors, ERYIGIT MEDICAL distance sensors, ERYIGIT MEDICAL vision sensors, ERYIGIT MEDICAL displacement sensors, ERYIGIT MEDICAL torque sensors, ERYIGIT MEDICAL speed sensors, ERYIGIT MEDICAL photoelectric sensors, ERYIGIT MEDICAL position sensors, ERYIGIT MEDICAL angle sensors, ERYIGIT MEDICAL tactile sensors, ERYIGIT MEDICAL temperature sensors, ERYIGIT MEDICAL pressure sensors, ERYIGIT MEDICAL flow sensors, ERYIGIT MEDICAL level sensors, ERYIGIT MEDICAL motion sensors, ERYIGIT MEDICAL process sensors. Original German imports. Welcome inquiries and orders from users.




Recommended products