
German CEMOP sensor CEMOP model CEMOP price
CEMOP sensors are devices that convert optical signals into electrical signals. Their operating principle is based on the photoelectric effect. The photoelectric effect refers to the phenomenon where electrons in a material absorb photon energy when light strikes certain substances, resulting in corresponding electrical effects. Based on the different manifestations of the photoelectric effect, it is classified into three categories: external photoelectric effect, internal photoelectric effect, and photovoltaic effect. Photoelectric devices include phototubes, photomultiplier tubes, photoresistors, photodiodes, phototransistors, and photocells. The performance and characteristic curves of photoelectric devices are analyzed. CEMOP sensor
- SKU
- _P004479660
- Category
- balluff sensor turck sensor in stock
- Brand
- CEMOP
- Tags
- Photoelectric Sensor / German sensors / Inductive Sensor / Measurement Sensors / CEMOP sensor
CEMOP sensor classification
Load cells are classified into 8 types based on conversion methods, including photoelectric, hydraulic, electromagnetic force, capacitive, magnetic pole variation, vibratory, gyroscope, and resistive strain gauge types, with resistive strain gauge being the most widely used. 1) Photoelectric type: Includes grating and code disk types. Grating sensors use Moiré fringes formed by gratings to convert angular displacement into photoelectric signals. There are two gratings: one fixed grating and one moving grating mounted on the dial shaft. The measured object placed on the weighing platform rotates the dial shaft through the force transmission lever system, driving the moving grating to rotate and causing the Moiré fringes to move. By using a phototube, conversion circuit, and display instrument, the number of moved Moiré fringes can be calculated to determine the angle of grating rotation, thereby determining and reading the mass of the measured object. Code disk sensor: The code disk (symbol plate) is a piece of transparent glass mounted on the dial shaft, featuring black and white codes arranged according to a specific encoding method. When the measured object on the weighing platform rotates the dial shaft via the force transmission lever, the code disk also rotates by a certain angle. A photocell receives the light signal passing through the code disk and converts it into an electrical signal, which is then digitally processed by the circuit, finally displaying the number representing the measured mass on the display. Photoelectric sensors were mainly used in electromechanical combination scales. 2) Hydraulic type: When subjected to the gravity P of the measured object, the pressure of the hydraulic oil increases, with the increase proportional to P. By measuring the increased pressure value, the mass of the measured object can be determined. Hydraulic sensors have a simple and robust structure and a large measurement range, but accuracy generally does not exceed 1/100. 3) Capacitive type: It operates based on the proportional relationship between the oscillation frequency f of the capacitor oscillator circuit and the distance d between the plates. There are two plates, one fixed and the other movable. When the measured object is loaded onto the weighing platform, the leaf spring deflects, changing the distance between the two plates, which in turn changes the oscillation frequency of the circuit. By measuring the change in frequency, the mass of the measured object on the weighing platform can be calculated. Capacitive sensors consume little power, have low cost, and offer an accuracy of 1/200 to 1/500.
CEMOP sensor features
Resistors, inductors, and capacitors are the three major types of passive components in electronics. A capacitive sensor is a sensor that converts changes in the measured quantity into changes in capacitance; it is essentially a capacitor with variable parameters. Capacitive sensors have the following advantages: high impedance, low power consumption, and requiring only very low input energy. They can achieve large change magnitudes, resulting in high signal-to-noise ratio and system stability. Fast dynamic response, with operating frequencies reaching several megahertz. They allow non-b contact measurement, and the measured object can be either a conductor or a semiconductor. Simple structure and strong adaptability, allowing operation in harsh environments such as high/low temperatures and strong radiation, leading to wide application. With the development of electronic technology and computer technology, disadvantages of capacitive sensors, such as susceptibility to interference and distributed capacitance, are continuously overcome. Furthermore, capacitive grid displacement sensors and integrated capacitive sensors have been developed. Therefore, they are widely used in non-electrical quantity measurement and automatic detection, capable of measuring parameters such as pressure, displacement, speed, acceleration, A degree, thickness, liquid level, humidity, vibration, and component content. Capacitive sensors have promising development prospects.
CEMOP sensor installation precautions
1) Handle load cells with care, especially small-capacity sensors using aluminum alloy as the elastic body. Any impact or drop caused by vibration is likely to result in significant output errors.
2) When designing the loading device and during installation, ensure that the line of action of the loading force coincides with the force axis of the load cell to minimize the effects of tilting and eccentric loads.
3) Regarding leveling. If using a load cell, adjust the installation plane of its base with a spirit level until it is horizontal. If multiple sensors are used for simultaneous measurement, their base installation surfaces should be kept as level as possible. The main purpose of this is to ensure that the force borne by each sensor is basically consistent.
4) Determine the rated load of the sensor used based on the load cell capacity selection specified in its instructions.
5) To prevent chemical corrosion, apply Vaseline to the outer surface of the load cell during installation. Avoid direct sunlight and environments with drastic temperature changes.
6) Install bypasses made of copper braided wire at both ends of the load cell loading device.
7) Do not extend the cable yourself. If extension is absolutely necessary, solder the joints and apply moisture-proof sealant.
8) It is best to use baffles to cover the sensor around the load cell. This prevents debris from falling into the moving parts of the sensor, which could affect its measurement accuracy.
9) Keep the sensor cable away from high-power power lines or places with pulse waves. If avoidance is impossible, run the load cell cable separately through an iron pipe and shorten the connection distance as much as possible.
10) Determine the rated load of the sensor used based on the load cell capacity selection specified in its instructions. Although load cells have a certain overload capacity, avoid such situations during installation and use. Even short-term overloading may cause permanent damage to the sensor.
11) For high-precision applications, preheat the load cell and instrument for 30 minutes before use.
Weidou Intelligent Technology specializes in selling German CEMOP sensors, CEMOP proximity sensors, CEMOP distance sensors, CEMOP vision sensors, CEMOP displacement sensors, CEMOP torque sensors, CEMOP speed sensors, CEMOP photoelectric sensors, CEMOP position sensors, CEMOP angle sensors, CEMOP tactile sensors, CEMOP temperature sensors, CEMOP pressure sensors, CEMOP flow sensors, CEMOP level sensors, CEMOP motion sensors, CEMOP process sensors. Original German imports. Welcome inquiries and orders from users.






