
Germany BLUE CHIPS sensor BLUE CHIPS model BLUE CHIPS price
BLUE CHIPS sensor pressure sensor for level measurement. The static pressure submersible level transmitter (level gauge) is based on the principle that the static pressure of the measured liquid is proportional to its height. It uses advanced foreign isolated diffused silicon sensitive elements or ceramic capacitive pressure sensitive sensors to convert static pressure into electrical signals, which are then converted into standard electrical signals (typically 4 to 20mA/15VDC) after temperature compensation and linear correction. The BLUE CHIPS sensor structure consists of a scale grating and a grating readhead. The figure on the right shows
- SKU
- _P004479580
- Category
- balluff sensor turck sensor in stock
- Brand
- BLUE CHIPS
- Tags
- Photoelectric Sensor / German sensors / Inductive Sensor / Measurement Sensors / BLUE CHIPS sensor
BLUE CHIPS sensor structure
It consists of a scale grating and a grating readhead. The figure on the right shows the structure of the grating ruler.
The key part of the grating detection device is the grating readhead, which consists of a light source, condensing lens, index grating, photoelectric elements, and adjustment mechanisms. There are many structural forms of grating readheads, classified by their structural characteristics and application scenarios into direct-receiving readheads (also known as silicon photovoltaic cell readheads, mirror-image readheads, beam-splitter readheads, and metal grating reflective readheads).
BLUE CHIPS sensor principle
The essence of a grating displacement sensor is to measure position using the grating pitch as a standard ruler. High-resolution grating rulers are generally expensive and difficult to manufacture. To improve system resolution, Moiré fringes need to be subdivided; grating ruler sensor systems mostly use electronic subdivision methods. When two gratings overlap at a slight angle, Moiré fringes are generated in a direction roughly perpendicular to the grating lines. As the grating moves, the Moiré fringes move up and down accordingly. This converts the measurement of grating pitch into the measurement of the number of Moiré fringes. Within one Moiré fringe width, placing 4 photoelectric devices at specific intervals enables electronic subdivision and direction determination. For example, for a grating ruler with 50 line pairs per mm, the grating pitch is 0.02mm. With four-fold subdivision, counting pulses with a resolution of 5μm can be obtained, achieving high precision in general industrial measurement and control. Since displacement is a vector, both its magnitude and direction must be detected, requiring at least two photoelectric signals with different phases. To eliminate common-mode interference, DC components, and even harmonics, differential amplifiers composed of low-drift operational amplifiers are typically used. The 4 photoelectric signals obtained from 4 photosensitive devices are sent to the input terminals of 2 differential amplifiers respectively. The two signals output from the differential amplifier have a phase difference of π/2. To obtain direction determination and counting pulses, these two signals must be shaped, first into square waves with a duty cycle of 1:1. Then, by comparing the phase of the square waves, the movement direction of the grating ruler can be determined. By counting the square wave pulses, the displacement and speed of the grating ruler can be obtained.
BLUE CHIPS sensor usage precautions
When plugging and unplugging the connector of the linear encoder sensor and the digital readout unit, ensure the power is turned off. Install an external protective cover whenever possible, and promptly remove chips and oil that splash onto the scale to strictly prevent any foreign matter from entering the housing of the linear encoder sensor. Regularly check whether the mounting and connection screws are loose. To extend the service life of the dust-proof sealing strip, apply a thin, even layer of silicone oil to the strip, taking care not to let it splash onto the glass grating etched surface. To ensure the reliability of the linear encoder sensor, clean and wipe the linear encoder scale surface and the index grating surface at regular intervals using an ethanol mixture (each 50%), keeping the glass linear encoder scale surface clean. The linear encoder sensor must not be subjected to severe vibration or impact, as this may damage the linear encoder scale; if the scale fractures, the linear encoder sensor will fail. Do not disassemble the linear encoder sensor yourself, and never arbitrarily change the relative spacing between the main scale and the secondary scale. Doing so may compromise the accuracy of the linear encoder sensor and cause relative friction between the main and secondary scales, damaging the chrome layer and thus the grating lines, which renders the linear encoder scale unusable. Take care to prevent oil stains and water from contaminating the linear encoder scale surface, as this can disrupt the distribution of the grating lines and cause measurement errors. Avoid operating the linear encoder sensor in environments with severe corrosive effects, to prevent corrosion of the grating chrome layer and the linear encoder scale surface, which would degrade the quality of the linear encoder scale.
Weidou Intelligent Technology specializes in selling German BLUE CHIPS sensors, BLUE CHIPS proximity sensors, BLUE CHIPS distance sensors, BLUE CHIPS vision sensors, BLUE CHIPS displacement sensors, BLUE CHIPS torque sensors, BLUE CHIPS speed sensors, BLUE CHIPS photoelectric sensors, BLUE CHIPS position sensors, BLUE CHIPS angle sensors, BLUE CHIPS tactile sensors, BLUE CHIPS temperature sensors, BLUE CHIPS pressure sensors, BLUE CHIPS flow sensors, BLUE CHIPS level sensors, BLUE CHIPS motion sensors, BLUE CHIPS process sensors. Original imports from Germany. Welcome inquiries and orders.






