
German wasi fastener valve, wasi fastener model, wasi fastener price
The closing element of the wasi fastener valve is a plug-shaped disc. The sealing surface is flat or conical, and the disc moves linearly along the centerline of the valve seat. The stem movement type (common name: rising stem) also includes lift-and-rotate stem types. It can be used to control the flow of various fluids such as air, water, steam, various corrosive media, slurry, oil products, liquid metals, and radioactive media. Therefore, this type of shut-off stop valve is very suitable for isolation, regulation, and throttling. Since the opening or closing stroke of the valve stem for this type of valve is relatively short,
- SKU
- _P004479278
- Category
- moog valve rexroth valve
- Brand
- wasi fastener
- Tags
- Control Valve / German valves / Shut-off Valve / Check Valve / Control Valve / wasi fastener valve
wasi fastener valve stop valve features
Compared with another commonly used shut-off valve in industrial production, the gate valve, the stop valve has a simpler structure, making it easier to manufacture and maintain. In terms of service life, the sealing surface of the stop valve is not easily worn or scratched. During the opening and closing process, there is no relative sliding between the disc and the seat sealing surface, resulting in less wear and damage to the sealing surface, thus extending the service life of the sealing pair. The disc stroke of the stop valve is small during the fully open and fully closed processes, and its height is relatively smaller than that of the gate valve. The disadvantages of the stop valve are that the opening and closing torque is large and rapid opening and closing are difficult to achieve. Because the flow path inside the valve body is quite tortuous, the fluid flow resistance is high, causing significant loss of fluid power in the pipeline.
Precautions for wasi fastener valve performance testing
1) When valves of a specific specification are manufactured in batches, an official agency should be commissioned to perform the following performance tests: (1) Opening and closing torque of the valve under working pressure conditions; (2) Detection of the flow resistance coefficient of the valve under pipeline water transmission conditions.
2) The following tests should be performed on the valve before leaving the factory: (1) With the valve in the open position, the valve body shall withstand an internal pressure test at twice the valve's working pressure value; (2) With the valve in the closed position, both sides shall separately withstand 11 times the valve's working pressure value without leakage; however, for metal-sealed butterfly valves, the leakage value shall not exceed the relevant requirements.
wasi fastener valve operation
For stop valves, one must not only know how to install and maintain them but also how to operate them.
When opening or closing a stop valve, apply force steadily; do not use impact. Certain high-pressure stop valves designed for impact opening and closing have components that account for this impact force and cannot be equated with general stop valves.
When the stop valve is fully open, turn the handwheel back slightly to tighten the threads and prevent loosening and damage.
When the pipeline is first used, there may be a lot of dirt inside. You can slightly open the stop valve and use the high-speed flow of the medium to flush it away, then close it gently (do not close quickly or forcefully to prevent residual impurities from damaging the sealing surface), and then open it again. Repeat this process several times to flush out the dirt before putting it into normal operation.
For normally open stop valves, dirt may adhere to the sealing surface. When closing, use the above method to flush it clean, then close it tightly.
If the handwheel or handle is damaged or lost, replace it immediately. Do not use an adjustable wrench as a substitute to avoid damaging the square section of the valve stem, which could cause malfunction and lead to accidents in production.
For certain media, cooling after the stop valve is closed causes the valve components to contract. Operators should close the valve again at an appropriate time to ensure no fine gaps remain on the sealing surface. Otherwise, the medium flowing through the fine gaps at high speed can easily erode the sealing surface.
During operation, if the operation feels excessively difficult, analyze the cause. If the packing is too tight, loosen it appropriately. If the valve stem is skewed, notify personnel for repair. Some stop valves experience difficulty in opening when the closing element expands due to heat in the closed state. If opening is necessary at this time, loosen the valve cover threads by half to one turn to relieve stress on the valve stem, then turn the handwheel.
Weidou Intelligent Technology specializes in selling German wasi fastener valves, wasi fastener safety valves, wasi fastener stop valves, wasi fastener control valves, wasi fastener solenoid valves, wasi fastener ball valves, wasi fastener proportional valves, wasi fastener diaphragm valves, wasi fastener butterfly valves, wasi fastener hydraulic actuated valves, wasi fastener check valves, wasi fastener pressure reducing valves, wasi fastener relief valves, wasi fastener sequence valves, wasi fastener balance valves, wasi fastener throttle valves, wasi fastener directional control valves. Original German imports. Welcome customers to inquire and order.






