Weidou Intelligent Technology (Shanghai) Co., Ltd.
中文
WDUTECH industrial automation products and services
Categories and filters

Home/Products/ moog valve rexroth valve

German roman seliger valves, roman seliger models, roman seliger prices

German roman seliger valves, roman seliger models, roman seliger prices

The closure member of the roman seliger valve is a plug-shaped disc. The sealing surface is flat or conical, and the disc moves linearly along the centerline of the valve seat. The stem movement type (common name: rising stem) also includes lift-and-rotate stems. It can be used to control the flow of various types of fluids such as air, water, steam, various corrosive media, slurry, oil products, liquid metals, and radioactive media. Therefore, this type of stop valve is very suitable for shut-off, regulation, and throttling. Since the opening or closing stroke of the valve stem for this type of valve is relatively short,

SKU
_P004479222
Category
moog valve rexroth valve
Tags
Control Valve / German valves / Shut-off Valve / Check Valve / Control Valve / roman seliger valve
The closure member of the roman seliger valve is a plug-shaped disc. The sealing surface is flat or conical, and the disc moves linearly along the centerline of the valve seat. The stem movement type (common name: rising stem) also includes lift-and-rotate stems. It can be used to control the flow of various types of fluids such as air, water, steam, various corrosive media, slurry, oil products, liquid metals, and radioactive media. Therefore, this type of stop valve is very suitable for shut-off, regulation, and throttling. Since the opening or closing stroke of the valve stem for this type of valve is relatively short, and it has a very reliable shut-off function, and since the change in the valve seat passage is directly proportional to the disc stroke, it is very suitable for flow regulation.


roman seliger valve globe valve features


Compared with another commonly used shut-off valve in industrial production, the gate valve, the globe valve is simpler in structure, making it easier to manufacture and maintain. In terms of service life, the sealing surface of the globe valve is not easily worn or scratched. During the opening and closing process, there is no relative sliding between the disc and the seat sealing surface, resulting in less wear and scratching on the sealing surface, thus extending the service life of the sealing pair. The disc stroke of the globe valve during full opening and closing is small, and its height is relatively smaller than that of the gate valve. The disadvantages of the globe valve are that the opening and closing torque is large and rapid opening and closing is difficult to achieve. Because the flow path inside the valve body is quite tortuous, the fluid flow resistance is high, causing significant loss of fluid power in the pipeline.


Precautions for roman seliger valve performance testing


1) When valves of a specific specification are manufactured in batches, an official agency should be commissioned to perform the following performance tests: (1) Opening and closing torque of the valve under working pressure conditions; (2) Detection of the flow resistance coefficient of the valve under pipeline water transmission conditions. 2) The following tests should be performed on the valve before leaving the factory: (1) With the valve in the open position, the valve body shall withstand an internal pressure test at twice the valve's working pressure; (2) With the valve in the closed position, both sides shall separately withstand 11 times the valve's working pressure without leakage; however, for metal-sealed butterfly valves, the leakage value shall not exceed the relevant requirements.


roman seliger valve operation


For globe valves, one must not only know how to install and maintain them but also how to operate them. When opening or closing a globe valve, apply force steadily; do not use impact. Certain high-pressure globe valves designed for impact opening and closing have components that account for this impact force and cannot be equated with standard globe valves. When the globe valve is fully open, turn the handwheel back slightly to tighten the threads and prevent loosening and damage. When the pipeline is first used, there may be a lot of dirt inside. You can slightly open the globe valve and use the high-speed flow of the medium to flush it away, then close it gently (do not close quickly or forcefully to prevent residual impurities from damaging the sealing surface), then open it again. Repeat this process several times to flush out the dirt before putting it into normal operation. For frequently open globe valves, dirt may adhere to the sealing surface. When closing, use the above method to flush it clean, then close it tightly. If the handwheel or handle is damaged or lost, replace it immediately. Do not use an adjustable wrench as a substitute to avoid damaging the square section of the valve stem, which could lead to ineffective opening/closing and cause accidents in production. For certain media, cooling after the globe valve is closed causes the valve parts to contract. Operators should close it again after an appropriate time to ensure no fine gaps remain on the sealing surface; otherwise, the medium flowing through the fine gaps at high speed can easily erode the sealing surface. During operation, if the operation feels excessively difficult, analyze the cause. If the packing is too tight, loosen it appropriately. If the valve stem is skewed, notify personnel for repair. Some globe valves experience difficulty in opening when the closure member expands due to heat in the closed state. If opening is necessary at this time, loosen the valve cover threads by half to one turn to relieve stress on the valve stem, then turn the handwheel.



Weidou Intelligent Technology specializes in selling German roman seliger valves, roman seliger safety valves, roman seliger globe valves, roman seliger control valves, roman seliger solenoid valves, roman seliger ball valves, roman seliger proportional valves, roman seliger diaphragm valves, roman seliger butterfly valves, roman seliger hydraulic actuated valves, roman seliger check valves, roman seliger pressure reducing valves, roman seliger relief valves, roman seliger sequence valves, roman seliger balance valves, roman seliger throttle valves, roman seliger directional control valves. Original imports from Germany. Welcome customers to inquire and order.




Recommended products