Weidou Intelligent Technology (Shanghai) Co., Ltd.
中文
WDUTECH industrial automation products and services
Categories and filters

Home/Products/ moog valve rexroth valve

German gmf components valves, gmf components models, gmf components prices

German gmf components valves, gmf components models, gmf components prices

gmf components valves are known as steam traps, also called automatic drains or condensate dischargers. They are categorized for use in steam systems and gas systems. Steam traps are installed at the end of steam-heated pipelines to continuously discharge condensate from the pipes to the outside. Most steam traps can automatically distinguish between steam and water (excluding thermostatic types), thereby achieving automatic steam blocking and condensate drainage. Steam traps are widely used in industries such as petrochemicals, food and pharmaceuticals, and power plants, playing a significant role in energy saving and emission reduction. gmf com

SKU
_P004479090
Category
moog valve rexroth valve
Tags
Control Valve / German valves / Shut-off Valve / Check Valve / Control Valve / gmf components valve
gmf components valves are known as steam traps, also called automatic drains or condensate dischargers. They are categorized for use in steam systems and gas systems. Steam traps are installed at the end of steam-heated pipelines to continuously discharge condensate from the pipes to the outside. Most steam traps can automatically distinguish between steam and water (excluding thermostatic types), thereby achieving automatic steam blocking and condensate drainage. Steam traps are widely used in industries such as petrochemicals, food and pharmaceuticals, and power plants, playing a significant role in energy saving and emission reduction.


gmf components valve classification


1) Free float steam trap: Simple structure, with only one moving part inside: a finely polished stainless steel hollow float ball, which acts as both the float and the opening/closing component. There are no wear-prone parts, resulting in a long service life. The steam trap interior features a Y series automatic air vent device, which is highly sensitive, automatically vents air, and ensures high operational quality. When the equipment starts up, air in the pipeline is discharged through the Y series automatic air vent device. Low-temperature condensate enters the steam trap, causing the condensate level to rise and the float to rise, opening the valve. Condensate is rapidly discharged, steam quickly enters the equipment, and the equipment heats up rapidly. The temperature-sensitive liquid in the Y series automatic air vent device expands, closing the automatic air vent. The steam trap begins normal operation; the float rises and falls with the condensate level, blocking steam and draining condensate. The valve seat of the free float steam trap is always below the liquid level, forming a water seal with no steam leakage, resulting in good energy-saving effects. Minimum working pressure 0.01Mpa, continuous drainage is unaffected by temperature and working pressure fluctuations from 0.01Mpa up to the maximum operating pressure range. It can discharge condensate at saturation temperature, with a minimum subcooling of 0℃, ensuring no water remains in the heating equipment and allowing it to achieve optimal heat exchange efficiency. The back pressure rate is greater than 85%, making it one of the most ideal steam traps for process heating equipment. 2) Free semi-float steam trap: The free semi-float steam trap has only one moving part: a semi-float bucket with the opening facing downward. The bucket serves as both the opening/closing component and the sealing component. The entire spherical surface provides sealing, offering a long service life, resistance to water hammer, no wear-prone parts, fault-free operation, durability, and no steam leakage. The back pressure rate is greater than 80%. It can discharge condensate at saturation temperature, with a minimum subcooling of 0℃, ensuring no water remains in the heating equipment and allowing it to achieve optimal heat exchange efficiency. When the device starts up, air and low-temperature condensate in the pipeline enter the steam trap through the launch tube. The bimetallic air vent element inside the valve pushes the bucket open, opening the valve, and air and low-temperature condensate are rapidly discharged. When steam enters the bucket, the bucket generates upward buoyancy. Simultaneously, the temperature inside the valve rises, causing the bimetallic air vent element to contract. The bucket floats toward the valve port, closing the valve. When the steam inside the bucket condenses into water, the bucket loses buoyancy and sinks, opening the valve and rapidly discharging condensate. When steam enters the bucket again, the valve closes again, operating intermittently and continuously. 3) Lever float steam trap: The basic characteristics of the lever float steam trap are the same as those of the free float type. The internal structure consists of a float connected to a lever that drives the valve core, opening and closing the valve according to the rise and fall of the condensate level. The lever float steam trap uses double valve seats to increase condensate discharge capacity, achieving a small size with large discharge volume. The maximum condensate discharge reaches 100 tons/hour, making it the most ideal steam trap for large heating equipment. 4) Inverted bucket steam trap: Inside the inverted bucket steam trap is an inverted bucket acting as the level-sensitive component, with the bucket opening facing downward. The inverted bucket is connected to a lever that drives the valve core to open and close the valve. The inverted bucket steam trap can vent air, is resistant to water hammer, and has good anti-fouling performance. The subcooling is small, the steam leakage rate is less than 3%, and the maximum back pressure rate is 75%. It has more connecting parts and is less sensitive than the free float steam trap. Since the inverted bucket steam trap relies on the upward buoyancy of steam to close the valve, it is not suitable for selection when the working pressure differential is less than 0.1MPA. When the device starts up, air and low-temperature condensate in the pipeline enter the steam trap. The inverted bucket drops due to its own weight, and the lever connected to the inverted bucket drives the valve core to open the valve, rapidly discharging air and low-temperature condensate. When steam enters the inverted bucket, the steam generates upward buoyancy, causing the inverted bucket to rise. The connected lever drives the valve core to close the valve. A small hole is opened on the inverted bucket. When part of the steam escapes through the small hole, another part condenses into water. The inverted bucket loses buoyancy and sinks due to its own weight. The lever connected to the inverted bucket drives the valve core to open the valve, cycling the operation and draining intermittently. 5) Combined superheated steam trap: The combined superheated steam trap has two isolated valve chambers connected by two stainless steel tubes. It is a combination of a float-type and an inverted bucket-type steam trap. The valve structure is advanced and reasonable. Under working conditions of superheat, high pressure, and low load, it can timely discharge condensate formed when superheated steam disappears, effectively preventing superheated steam leakage, and ensuring high operational quality. The maximum allowable temperature is 600℃. The valve body is made entirely of stainless steel, and the valve seat is made of hard alloy steel, offering a long service life. It is a specialized steam trap for superheated steam, holding two national patents and filling a domestic gap. When condensate enters the lower valve chamber, the float of the auxiliary valve rises with the liquid level, and the float seals the steam inlet pipe hole. Condensate rises through the inlet conduit to the main valve chamber. The inverted bucket drops due to its own weight, driving the valve core to open the main valve and discharge condensate. When the condensate level in the auxiliary valve chamber drops, the float descends with the liquid level, and the auxiliary valve opens.Steam enters the inverted bucket in the upper main valve chamber through the steam inlet pipe. The inverted bucket generates upward buoyancy, and the inverted bucket drives the valve core to close the main valve. When the condensate level in the auxiliary valve chamber rises again, the next cycle begins, draining intermittently.


gmf components valve selection


When selecting a steam trap, do not choose based solely on maximum discharge capacity. Pay special attention: it is strictly prohibited to select a steam trap based only on pipe diameter. Selection must be based on steam trap selection principles and combined with the specific conditions of the condensate system. Generally, selection should be made based on the following three aspects. 1) First, determine the type of steam trap based on the heating equipment and the requirements for condensate discharge. For heating equipment requiring the fastest heating speed and strict control of heating temperature, it is necessary to ensure that condensate does not accumulate in the heating equipment; any water present must be discharged. In this case, it is best to choose a mechanical steam trap capable of discharging saturated water. Because it discharges water as soon as it appears, it can timely eliminate adverse consequences caused by water accumulation in the equipment, rapidly improving and ensuring the heating efficiency required by the equipment. For heating equipment with a large heating surface and less stringent requirements for heating speed and temperature control, water accumulation is permissible, such as in steam heating drainage and process tracing line drainage. In these cases, it is best to choose a thermostatic steam trap. For medium and low-pressure steam transmission pipelines, condensate generated in the pipeline must be rapidly and completely discharged; otherwise, water hammer accidents are likely to occur. An increased water content in steam lowers the steam temperature, failing to meet the process requirements of steam-using equipment. Therefore, it is best to choose mechanical steam traps for medium and low-pressure steam transmission pipelines. 2) Second, determine the nominal pressure and valve body material of the steam trap based on the maximum working pressure and maximum working temperature of the steam-using equipment; determine the connection method and installation method of the steam trap, etc. The nominal pressures of steam traps are generally divided into: 0.6Mpa, 1.0Mpa, 2.0Mpa, 2.5Mpa, 4.0Mpa, 5.0Mpa. During selection, the nominal pressure of the steam trap must not be lower than the maximum working pressure of the steam-using equipment. At the same time, select the valve body material based on the nominal pressure, maximum working temperature, and installation environment of the steam trap. For nominal pressure ≤ 1.0Mpa, select cast iron or carbon cast steel; for nominal pressure > 1.0Mpa, select carbon cast steel or alloy cast steel. The maximum working temperature of the steam trap is determined by the steam used by the steam-using equipment; the selected temperature should not be lower than the temperature of the steam used. Steam traps have two installation methods: horizontal and vertical, determined by the connection position between the pipeline and the steam trap. Connection methods for steam traps include threaded, flanged, welded, and wafer types. These must be determined based on the maximum working pressure, maximum working temperature of the steam trap, and the requirements of the corresponding connection parts of the steam-using equipment. 3) Finally, determine the performance parameters of the steam trap based on the discharge volume. In addition to matching parameters such as pressure and temperature of the steam trap with the conditions of the equipment used, the discharge volume of the steam trap under various pressure differentials is an important factor in selection. If the discharge volume of the selected and installed steam trap is too small, it cannot timely discharge all condensate reaching the steam trap, causing condensate blockage and backflow, ultimately leading to clogging and significantly reducing equipment heating efficiency. Conversely, selecting a steam trap with too large a discharge volume will lead to premature wear and failure of the valve closing components. As the valve body size increases, manufacturing costs also increase, which is uneconomical. Therefore, the amount of condensate generated in the equipment or pipeline must be correctly measured or calculated to provide conditions for the correct selection of steam traps.


gmf components valve structure


Good sealing performance, but the entire load of the working medium on the ball is transmitted to the outlet sealing ring. Therefore, consideration must be given to whether the sealing ring material can withstand the working load of the ball medium. Under high pressure impact, the ball may shift. This structure is generally used for medium and low-pressure ball valves. Fixed ball valve Fixed ball valve The ball of the fixed ball valve is fixed and does not move under pressure. Fixed ball valves are equipped with floating valve seats. Under medium pressure, the valve seat moves, pressing the sealing ring tightly against the ball to ensure sealing. Bearings are usually installed on the upper and lower shafts of the ball, resulting in low operating torque, making them suitable for high-pressure and large-diameter valves. To reduce the operating torque of ball valves and increase sealing reliability, oil-sealed ball valves have emerged. Special lubricating oil is injected between the sealing surfaces to form an oil film, which enhances sealing performance and reduces operating torque, making them more suitable for high-pressure, large-diameter ball valves.



Weidou Intelligent Technology professionally sells German gmf components valves, gmf components safety valves, gmf components globe valves, gmf components control valves, gmf components solenoid valves, gmf components ball valves, gmf components proportional valves, gmf components diaphragm valves, gmf components butterfly valves, gmf components hydraulic actuated valves, gmf components check valves, gmf components pressure reducing valves, gmf components relief valves, gmf components sequence valves, gmf components balance valves, gmf components throttle valves, gmf components directional control valves. Original German imports. Welcome customers to inquire and order.




Recommended products