bar vavle valve is an important component of the safety system of thermal power plant units. It is a key safety device to ensure the safe operation of extraction steam units and prevent turbine overspeed accidents caused by steam backflow in extraction pipelines. To this end, Article 8.1.10 of the "Twenty-Five Key Requirements for Preventing Major Accidents in Electric Power Production" issued by the State Power Corporation specifically emphasizes that "the adjustable extraction steam check valves of extraction steam units shall be tight, with reliable interlock action, and extraction steam stop valves capable of rapid closure shall be installed to prevent overspeed caused by extraction steam backflow." Currently, extraction steam units are designed to

SKU
_P004479013
Category
moog valve rexroth valve
Tags
Control Valve / German valves / Shut-off Valve / Check Valve / Control Valve / bar vavle valve
bar vavle valves are a critical component of the safety system for thermal power plant units. They are essential safety devices that ensure the safe operation of extraction steam units and prevent turbine overspeed accidents caused by steam backflow in the extraction steam piping. To this end, Article 8.1.10 of the "Twenty-Five Key Requirements for Preventing Major Accidents in Power Production," issued by the State Power Corporation, specifically emphasizes that "the adjustable extraction steam check valves on extraction steam units must be tight, with reliable interlock action, and quick-closing extraction steam stop valves must be installed to prevent overspeed caused by extraction steam backflow." Currently, the safety measure adopted to prevent overspeed due to extraction steam backflow in extraction steam units is the installation of check valves on the extraction steam piping. However, the currently applied extraction steam check valves have defects such as slow closing response, inadequate sealing, poor reliability, and an inability to effectively prevent extraction steam backflow. These defects have previously caused several major accidents involving severe overspeed due to extraction steam backflow, posing significant hidden dangers to safe production. Therefore, it is highly necessary to install a new type of faster-acting, safer, and more reliable quick-closing valve on this pipeline to effectively prevent accidents and substantially improve the safety performance of the unit.


bar vavle valve structure


It consists of four parts: hydraulic actuator, mechanical conversion mechanism, triple-offset butterfly valve, and electrical control system. 1) Hydraulic Actuator The hydraulic actuator consists of an integrated hydraulic control system, including a power oil source, accumulator, control valve block, and hydraulic cylinder. The output of the actuator's hydraulic cylinder is linear motion. The cylinder piston is connected to the rack of the mechanical conversion mechanism via threads. 2) Mechanical Conversion Mechanism The mechanical conversion mechanism consists of a rack and a gear transmission mechanism. It converts the linear output of the hydraulic cylinder into angular output. The mechanical conversion mechanism is connected to the valve body via a flange. The gears inside are directly connected to the drive of the butterfly valve, driving the valve disc to perform various actions, thereby realizing the actuator's control over the butterfly valve and completing functions such as quick closure. 3) Valve The valve offers good tightness, zero leakage, no jamming, long service life, and low torque. To ensure the safety and reliability of valve operation, the valve paired with the electro-hydraulic control quick-shutdown device should be a high-quality triple-offset metal-sealed butterfly valve. Various imported and domestic valves are available. 4) Electrical Control System The electrical control part consists of an operation unit, controller, and display and alarm unit. The operation unit supports automatic, manual, remote, and local operation modes. In automatic mode, it receives protection signals such as turbine main steam valve closure or oil circuit breaker tripping to implement quick valve closure. Manual remote operation can be performed from the control room to implement quick valve closure, normal opening and closing, and valve activity tests. A manual local operation mode with the same functions as manual remote operation is provided to facilitate adjustment tests and emergency handling in accident situations. The controller receives information from the operation unit, performs logical judgments, outputs function commands, and controls solenoid valves to achieve various control functions. The solenoid valves are normally de-energized and operate when energized. The controller also receives system oil pressure signals to control the start and stop of the oil pump, maintaining constant pressure in the oil system. The display and alarm unit provides status indications for valve "Open," "Close," "Activity Test," and "Quick Close." It also monitors and alarms for faults such as low oil system pressure, low oil tank level, low accumulator gas pressure, and motor overheating.


bar vavle valve functions


1) Slow Opening/Closing When PLC receives a slow opening/closing signal, it sends pulse commands to the stepper motor, causing the motor to rotate in the corresponding direction. This directs high-pressure oil into the right or left side of the double-acting cylinder, driving the gears and valve to move in the opening or closing direction. Upon receiving signals for the fully open or fully closed positions, PLC continues to send commands for a period to ensure the valve reaches the fully open or fully closed position. 2) Position Holding When PLC does not receive any command, the motor, pump, and gears remain stationary. Since the hydraulic components in the equipment are leak-free, the valve holds its position in this state. 3) Quick Closure When PLC receives a quick-close signal, PLC energizes the quick-close solenoid valve. The two chambers of the double-acting cylinder communicate to release oil pressure. Under the action of the quick-close spring, the valve rapidly moves to the fully closed position. 4) Buffering To reduce impact during the quick-closing process, variable throttling buffering is added to the double-acting cylinder when the valve closes to 10% of its travel. 5) Status Display and Alarm Displays working statuses such as valve "Open," "Close," and "Quick Close." It also monitors and alarms for faults such as "Drive Error" and "Valve Opening/Closing Time Too Long." Working Principle: The electro-hydraulic control quick-shutoff valve consists of an electrical control device, actuator, and valve. Control signals are output as control commands by the controller, driving the valve action via the hydraulic actuator to achieve various control functions.


bar vavle valve working principle


The electro-hydraulic control quick-shutoff valve consists of an electrical control device, actuator, and valve. Control signals are output as control commands by the controller, driving the valve action via the hydraulic actuator to achieve various control functions.



Weidou Intelligent Technology specializes in selling German bar vavle valves, bar vavle safety valves, bar vavle stop valves, bar vavle control valves, bar vavle solenoid valves, bar vavle ball valves, bar vavle proportional valves, bar vavle diaphragm valves, bar vavle butterfly valves, bar vavle hydraulic transmission valves, bar vavle check valves, bar vavle pressure reducing valves, bar vavle relief valves, bar vavle sequence valves, bar vavle balance valves, bar vavle throttle valves, and bar vavle directional control valves. Original imports from Germany. Welcome inquiries and orders from customers.