German ahlsell valves ahlsell models ahlsell prices
ahlsell valves are valves that reduce the inlet pressure to a required outlet pressure through regulation, and rely on the energy of the medium itself to automatically maintain stable outlet pressure. From the perspective of fluid mechanics, a pressure reducing valve is a throttling element with variable local resistance, i.e., by changing the throttling area, the flow velocity and kinetic energy of the fluid are altered, causing different pressure losses, thereby achieving pressure reduction. Then, through the adjustment of the control and regulation system, the fluctuation of the pressure downstream of the valve is balanced with the spring force, keeping the downstream pressure constant within a certain error range.
- SKU
- _P004478968
- Category
- moog valve rexroth valve
- Brand
- ahlsell
- Tags
- Control Valve / German valves / Shut-off Valve / Check Valve / Control Valve / ahlsell valves
ahlsell valve operating principle
The pressure reducing valve reduces water pressure by means of the local resistance of the flow channel inside the valve. The range of pressure drop is automatically regulated by the water pressure difference between the inlet and outlet on both sides of the diaphragm or piston connected to the valve disc. The fixed-ratio pressure reduction principle utilizes the water pressure ratio of the floating piston in the valve body; the pressure reduction ratio between the inlet and outlet ends is inversely proportional to the area ratio of the pistons on the inlet and outlet sides. This type of pressure reducing valve operates smoothly without vibration; there is no spring inside the valve body, eliminating concerns about spring corrosion and metal fatigue failure. It has good sealing performance without leakage, thus reducing both dynamic pressure (when water is flowing) and static pressure (when flow rate is 0). In particular, it reduces pressure without affecting the water flow rate. A pressure reducing valve regulates the flow of the medium by adjusting the opening degree of the closing member inside the valve body, reducing the pressure of the medium. At the same time, it adjusts the opening degree of the closing member by means of the pressure downstream of the valve, keeping the downstream pressure within a certain range. Cooling water is injected inside the valve body or downstream to reduce the temperature of the medium; such a valve is called a pressure reducing and desuperheating valve. Kuaiyiyou Automation Selection includes pressure reducing valves. The characteristic of this valve is that it maintains the outlet pressure and temperature within a certain range even when the inlet pressure changes continuously.
ahlsell valve installation precautions
1) Before installing the valve, carefully verify whether the model and specifications of the valve used match the design; 2) Check against the valve model and factory instruction manual to determine if the valve can be applied under the required conditions; 3) When lifting the valve, ropes should be tied to the flange connection between the valve body and bonnet; do not tie them to the handwheel or valve stem to avoid damaging the valve stem and handwheel; 4) When installing valves on horizontal pipes, the valve stem should be vertically upward; downward installation of the valve stem is not permitted; 5) When installing valves, do not use forced alignment connections by pulling or dragging, to avoid damage caused by uneven stress; 6) Rising stem gate valves should not be installed in underground damp locations to avoid corrosion of the valve stem.
ahlsell valve troubleshooting
In certain pressure reduction control circuits, the outlet pressure of the pressure reducing valve is used to control the control oil pressure of electro-hydraulic directional valves or externally controlled sequence valves. After the electro-hydraulic directional valve or externally controlled sequence valve shifts or operates, the flow rate at the outlet of the pressure reducing valve becomes zero, but the pressure must still maintain the originally set value. In this case, since the outlet flow of the valve is zero, the flow passing through the pressure reduction port is only the pilot flow. Since the pilot flow is very small, generally within 2L/min, the main valve pressure reduction port is basically close to the fully closed position (extremely small opening). The pilot flow exits from the triangular groove or inclined conical surface. If the fit of the main valve spool is too loose or wear is excessive, the leakage increases. According to the continuity theorem of flow, this part of the leakage must also flow from the damping hole of the main valve spool, i.e., the flow through the damping hole consists of two parts: pilot flow and leakage. Since the area of the damping hole and the oil pressure in the main valve spring chamber remain unchanged (the oil pressure in the spring chamber is determined by the pre-compression amount of the adjusted pressure regulating spring), an increase in the flow through the damping hole will inevitably cause the oil pressure in the lower chamber of the main valve to rise. Therefore, after the outlet pressure of the pressure reducing valve is set, if the outlet flow is zero, the outlet pressure will rise due to excessive looseness or wear of the main valve spool fit.
Weidou Intelligent Technology professionally sells German ahlsell valves, ahlsell safety valves, ahlsell globe valves, ahlsell control valves, ahlsell solenoid valves, ahlsell ball valves, ahlsell proportional valves, ahlsell diaphragm valves, ahlsell butterfly valves, ahlsell hydraulic transmission valves, ahlsell check valves, ahlsell pressure reducing valves, ahlsell relief valves, ahlsell sequence valves, ahlsell balance valves, ahlsell throttle valves, ahlsell directional valves. Original German imports. Welcome customers to inquire and order.