German Weinreich pump Weinreich model Weinreich price
Weinreich pumps are pumps in which the vanes in the rotor slots contact the pump casing (stator ring) to press the sucked liquid from the inlet side to the outlet side. There are two types depending on the classification: One) Specifically refers to vane pumps within positive displacement pumps. Two) Refers to the three dynamic pumps (centrifugal pumps, mixed-flow pumps, axial-flow pumps) or other special pumps. Such pump products are generally not called vane pumps. However, in monographs, vane pumps almost entirely refer to centrifugal pumps, mixed-flow pumps, axial-flow pumps, etc. Depending on whether the theoretical displacement per revolution is a fixed value or a variable value, they can be divided into variable displacement vane pumps and fixed displacement vane pumps.
- SKU
- _P004474282
- Category
- German-engineered pump, original imported
- Brand
- Weinreich
- Tags
- Gear Pump / Diaphragm Pump / Centrifugal Pump / Plunger Pump / Vacuum Pump / Screw Pump / Weinreich centrifugal pump
Weinreich pump operating principle
Its operating principle is similar to that of a single-acting vane pump; the only difference is that the stator surface consists of eight parts: two long-radius arcs, two short-radius arcs, and four transition curves, and the stator and rotor are concentric. With the rotor rotating clockwise as shown, the volume of the sealed working chamber gradually increases at the upper left and lower right corners (suction zone) and gradually decreases at the lower left and upper right corners (pressure zone); an oil-sealing zone separates the suction and pressure zones. For each revolution of the rotor, each sealed working chamber completes two suction and two pressure actions, hence it is called a double-acting vane pump. The two suction zones and two pressure zones of the pump are radially symmetric, so the hydraulic pressure acting on the rotor is radially balanced; thus, it is also called a balanced vane pump. The instantaneous flow of a double-acting vane pump is pulsating; when the number of vanes is a multiple of 4, the pulsation rate is low. Therefore, the number of vanes in double-acting vane pumps is generally chosen as 12 or 16.
Weinreich pump usage precautions
Gear pumps are suitable for various industries, with a wide range of transportable media. These gear pumps offer advantages such as robust construction, easy installation, easy disassembly, simple maintenance, uniform and continuous flow, slight wear, and long service life. 1) During the use of gear pumps, frequent greasing is required as lubricating grease evaporates easily; therefore, attention must be paid to replenishment and replacement, and cleanliness at the bearings must be maintained. 2) When in use or after use, place the electric oil pump in a relatively dry, non-corrosive, and clean environment. 3) Frequently inspect and maintain the gear pump during use. Check the electric oil drum, including the power cord, internal wiring, plug, and switch, to ensure they function normally. Check whether any bearing components are damaged. 4) Preserve every component of the gear pump. During disassembly and inspection, keep all parts clean and stored properly.
Weinreich pump maintenance
When using a gear pump, it is unavoidable to encounter wear on the gear pump, which leads to many problems, so it is necessary to learn the most common maintenance techniques for gear pumps. This enables accurate diagnosis of issues when they arise. Routine maintenance procedures are as follows: 1) Maintenance of the working surface: If the wear on the pump cover's working surface is minimal, you can manually remove the wear marks by lapping, that is, place a small amount of valve grinding compound on a flat platform or thick glass plate, then place the pump cover on top and lap it, until the wear marks are removed, and the working surface is flat. If the wear depth on the working surface of the pump cover exceeds zero point one millimeter, it must be repaired by first turning and then lapping. 2) Maintenance of the drive shaft bushing bore: The repair method for wear on the drive shaft bushing bore in the pump cover is the same as that for the housing's drive shaft bushing bore. Repair of the pump housing bore: After wear occurs in the pump housing bore, the sleeve insertion method is used for repair, which involves boring out the inner cavity and fitting a cast iron or steel sleeve. After inserting the sleeve, bore the inner cavity to the required dimensions, and grind off the portion of the sleeve protruding from the end face, ensuring it is flush with the pump housing mating surface. 3) Maintenance of the valve seat: Pressure-limiting valves come in two types: ball valves and plunger valves. After the ball valve seat wears, place a steel ball on the valve seat, then gently tap the steel ball with a metal rod, until the ball valve seats tightly against the valve seat. If the valve seat is severely worn, ream to remove the wear marks, and then use the above method to achieve a tight seal. After the plunger-type valve seat wears, add a small amount of valve grinding compound for lapping, lap until a tight seal is achieved. The above describes some basic maintenance of components for gear pumps, other different problems may be encountered during application, and these different problems must be carefully studied to identify their causes.
Weidou Intelligent Technology specializes in selling German Weinreich centrifugal pumps, Weinreich gear pumps, Weinreich diaphragm pumps, Weinreich centrifugal pumps, Weinreich piston pumps, Weinreich vacuum pumps, Weinreich screw pumps, Weinreich submersible pumps, Weinreich peristaltic pumps, Weinreich lubrication pumps, Weinreich vane pumps, Weinreich metering pumps, Weinreich hand pumps, Weinreich drum pumps, Weinreich cam pumps, Weinreich booster pumps, Weinreich liquid pumps, Weinreich air pumps. Original imports from Germany. Welcome inquiries and orders from users.