German parker pump parker model parker price
parker pumps are also known as positive displacement devices. Like a piston in a cylinder, when one tooth enters the fluid space of another tooth, the liquid and the tooth cannot occupy the same space simultaneously because liquids are incompressible. Thus, the liquid is mechanically squeezed out. Due to the continuous meshing of the teeth, this phenomenon occurs continuously, providing a continuous discharge volume at the pump outlet. The discharged volume is the same for each revolution of the pump. As the drive shaft rotates continuously, the pump discharges fluid without interruption. The flow rate of the pump is directly related to the pump's
- SKU
- _P004474214
- Category
- German-engineered pump, original imported
- Brand
- parker
- Tags
- Gear Pump / Diaphragm Pump / Centrifugal Pump / Plunger Pump / Vacuum Pump / Screw Pump / parker gear pump
parker pump operating principle
The concept of a gear pump is very simple. Its most basic form consists of two gears of identical size meshing and rotating within a closely fitted housing. The interior of this housing resembles an "8" shape, with the two gears installed inside. The outer diameter of the gears and their sides fit closely with the housing. Material from the extruder enters between the two gears at the suction inlet, filling this space. It moves along the housing as the teeth rotate and is finally discharged when the two teeth mesh. Gear pumps are also known as positive displacement devices. Like a piston in a cylinder, when one tooth enters the fluid space of another tooth, the liquid and the tooth cannot occupy the same space simultaneously because liquids are incompressible. Thus, the liquid is mechanically squeezed out. Due to the continuous meshing of the teeth, this phenomenon occurs continuously, providing a continuous discharge volume at the pump outlet. The discharged volume is the same for each revolution of the pump. As the drive shaft rotates continuously, the pump discharges fluid without interruption. The flow rate of the pump is directly related to the pump speed. In practice, there is a small amount of fluid loss within the pump because this fluid is used to lubricate the bearings and the sides of the gears. Furthermore, the pump body cannot have a gap-free fit, so it is impossible for the fluid to be discharged from the outlet 100%. Therefore, a small amount of fluid loss is inevitable, preventing the pump's operating efficiency from reaching 100%. However, the pump can still operate well, achieving an efficiency of 93% to 98% for most extruded materials. This type of pump is not significantly affected by changes in fluid viscosity or density during the process. If there is a damper, such as a filter screen or restrictor on the discharge side, the pump will push the fluid through them. If this damper changes during operation—i.e., if the filter screen becomes dirty or clogged, or if the back pressure of the restrictor increases—the pump will maintain a constant flow rate until the mechanical limit of the weakest component in the system is reached (a torque limiter is usually installed). The rotational speed of a pump is actually limited, primarily depending on the process fluid. If oil is being transported, the pump can rotate at high speeds; however, if the fluid is a high-viscosity polymer melt, this limitation increases significantly. It is crucial to fill the space between the two teeth on the suction inlet side with high-viscosity fluid. If this space is not completely filled, the pump cannot discharge an accurate flow rate. Therefore, the PV value (pressure × flow velocity) is another limiting factor and a process variable. Due to these limitations, gear pump manufacturers offer a range of products with different specifications and displacements (volume discharged per revolution). These pumps are matched to specific application processes to optimize system capacity and price.
parker pump usage precautions
Gear pumps are suitable for various industries and handle a wide range of media. These gear pumps offer advantages such as robust construction, easy installation, easy disassembly, simple maintenance, uniform and continuous flow, minimal wear, and long service life. 1) During the use of gear pumps, frequent greasing is required. Since lubricating grease evaporates relatively easily, attention must be paid to replenishment and replacement. Additionally, keep the bearing area clean. 2) When using or after using the electric oil pump, place it in a dry, non-corrosive, and clean environment. 3) Frequently inspect and maintain the gear pump during use. Check the electric oil drum, including the power cord, internal wiring, plug, and switch, to ensure they are functioning normally. Inspect bearing components for any damage. 4) Preserve every component of the gear pump. During disassembly and inspection, keep all parts clean and stored properly.
parker pump maintenance
When using a gear pump, wear of the gear pump is unavoidable, therefore many problems will arise, so it is necessary to learn the most common maintenance technique for gear pumps. This enables accurate diagnosis when problems occur. Routine maintenance techniques are as follows: 1) Maintenance of the working surface: If the wear on the pump cover working surface is relatively small, you can manually eliminate the wear marks by lapping, that is, place a small amount of valve grinding compound on a surface plate or thick glass plate, then place the pump cover on top and lap it, until the wear marks are removed and the working surface is flat. If the wear depth on the working surface of the pump cover exceeds zero point one millimeter, turning followed by lapping must be used for repair. 2) Maintenance of the drive shaft bushing bore: The repair method for wear of the drive shaft bushing bore on the pump cover is the same as that for wear of the drive shaft bushing bore in the housing. Repair of the pump housing bore: After the pump housing bore wears, the bore lining method is always used for repair, which involves boring out the inner bore and fitting a cast iron or steel bushing. After inserting the bushing, bore the inner cavity to the required dimensions, and grind off the bushing protruding from the end face so that it is flush with the pump housing mating surface. 3) Maintenance of the valve seat: Pressure-limiting valves come in two types: ball valves and plunger valves. After the ball valve seat wears, place a steel ball on the valve seat, then gently tap the steel ball with a metal rod, until the ball valve seats tightly against the valve seat. If the valve seat is severely worn, ream to remove the wear marks, and then use the above method to achieve a tight seal. After the plunger-type valve seat wears, a small amount of valve grinding compound can be added for lapping, lapping until a tight seal is achieved. The above describes some basic maintenance of components for gear pumps, other different problems may also be encountered during application, and these different problems must be carefully studied to identify their causes.
Weidou Intelligent Technology specializes in selling German parker gear pumps, parker gear pumps, parker diaphragm pumps, parker centrifugal pumps, parker piston pumps, parker vacuum pumps, parker screw pumps, parker submersible pumps, parker peristaltic pumps, parker lubrication pumps, parker vane pumps, parker metering pumps, parker hand pumps, parker barrel pumps, parker cam pumps, parker booster pumps, parker liquid pumps, and parker air pumps. Original imports from Germany. Customers are welcome to inquire and order.