NORIS Armaturen pumps are mechanical devices that meter the delivered liquid. They are often used in complete chemical dosing systems and are therefore also called dosing pumps. They are special positive displacement pumps designed to meet various strict process requirements, with flow rate steplessly adjustable within the 0-100% range for transporting liquids (especially corrosive liquids). NORIS Armaturen pump structure and classification: The pump consists of three parts: motor, transmission box, and cylinder body. The transmission box components consist of a cam mechanism, stroke adjustment mechanism, and ratio worm

SKU
_P004474207
Category
German-engineered pump, original imported
Tags
Gear Pump / Diaphragm Pump / Centrifugal Pump / Plunger Pump / Vacuum Pump / Screw Pump / NORIS Armaturen metering hand pump
NORIS Armaturen pumps are mechanical devices that meter the delivered liquid. They are often used in complete chemical dosing systems and are therefore also called dosing pumps. They are special positive displacement pumps designed to meet various strict process requirements, with flow rate steplessly adjustable within the 0-100% range for transporting liquids (especially corrosive liquids).


NORIS Armaturen pump structure and classification


The pump consists of three parts: motor, transmission box, and cylinder body. The transmission box components consist of a cam mechanism, stroke adjustment mechanism, and ratio worm gear mechanism; rotating the adjustment handwheel adjusts the tappet stroke, thereby changing the diaphragm extension distance to achieve flow rate adjustment. The cylinder body components consist of the pump head, suction valve assembly, discharge valve assembly, diaphragm base, etc. Dosing metering pumps can be classified by drive type into motor-driven and solenoid-driven. For motor-driven metering pumps, flow rate adjustment can be achieved by using a frequency converter to change the motor speed, or by adjusting the piston stroke. Installing a servo motor (ATE) allows left and right rotation to adjust the angle, increasing or decreasing the piston stroke. Solenoid-driven flow rate adjustment changes the reciprocating frequency of the diaphragm. It can accept pulse frequency from a flow meter or analog signals of 4~20mA, and can also accept analog 4~20mA signals from water quality instruments, with the controller regulating dosing. Flow rate can be adjusted manually via buttons, or the dosing amount can be controlled by a controller (PID).


NORIS Armaturen pump working principle


The motor drives the worm shaft via a coupling, and the worm gear reduces speed to rotate the main shaft and eccentric wheel. The eccentric wheel drives the tappet to reciprocate within the guide tube. Together with the diaphragm, the action of the check valves gradually creates a vacuum in the pump chamber, opening the suction valve to draw in liquid. When the diaphragm moves to the forward dead center, the suction valve closes, the discharge valve opens, and the liquid is discharged under the push of the diaphragm. The pump forms a continuous, pressurized, quantitative discharge of liquid through reciprocating motion with a regulated stroke. Pump flow rate adjustment is achieved by rotating the adjustment handwheel, which turns the adjustment screw, thereby changing the distance between tappets and altering the diaphragm stroke within the pump chamber to determine the flow rate. The scale on the adjustment handwheel determines the diaphragm stroke, with an accuracy of 95%.


NORIS Armaturen pump precautions


1) What important matters should be noted when operating a dosing system? Injection point pressure, stroke frequency, suction lift height, altitude, and chemical corrosiveness. 2) When the metering pump outlet is at atmospheric pressure, what methods can improve the pump's repeatable metering accuracy? Installing a valve spring on the metering pump discharge valve can improve repeatable metering accuracy, but the most effective improvement method is to install a backpressure valve at the end of the pipeline. 3) How to adjust the backpressure valve? When there is pressure at the suction end of the metering pump, the pressure at the discharge end must be at least 1bar higher than the suction end pressure. Never exceed the maximum working pressure of the metering pump. 4) If the transported liquid is not water, how is the suction lift height calculated? Divide the rated suction lift height of the metering pump by the specific gravity of the metered liquid. 5) How to set the safety valve pressure? The safety valve pressure can be adjusted within the rated working pressure range of the metering pump and must not exceed the maximum working pressure of the metering pump. The safety valve is designed to prevent overpressure operation of the metering pump. For example, if the maximum working pressure of the metering pump is 3bar, the safety valve pressure should be set to 3bar, or lower, to ensure normal operation of the metering pump. Overpressure operation is one of the main causes of metering pump damage. 6) How to select the appropriate pulse dampener volume? Multiply the metering capacity per stroke of the metering pump (ml) by 26 to obtain the minimum volume (ml) of the pulse dampener required to reduce 90% pulsation. 7) Under what circumstances is flooded suction used? When the metered liquid is volatile; when the metered liquid has a high specific gravity; when a high stroke frequency is required; when the metering pump operates at high altitudes; or when field applications require large storage tanks and self-priming by the metering pump is not feasible. 8) Can you provide some recommendations regarding metering pump head selection? What problems usually arise concerning chemical corrosion of the pump head/seals, and how can they be avoided? Problems with metering pump heads usually occur when metering acids, chlorine, fluorides, and hydrogen peroxide. Due to differences in chemical concentration and operating temperature, it is difficult to determine the specific pump head material. When metering fluorides, we recommend selecting Viton sealed PVC pump heads. For most chlorination applications, it is best to select EPDM sealed NP (plexiglass) pump heads. For metering hydrogen peroxide mixtures, only PTFE sealed PTFE pump heads or stainless steel pump heads can be selected. For metering concentrated hydrochloric acid, Viton sealed plexiglass pump heads are usually selected. For metering concentrated sulfuric acid, PTFE sealed PTFE pump heads can be selected. Chemical manufacturers will provide relevant recommendations, or consult ProMinent chemical resistance charts to determine the compatibility of chemicals with contact materials. 9) What influencing factors must be considered when metering liquids with the pump head? The main factors to consider are liquid viscosity, specific gravity, vapor pressure, and temperature.



Weidou Intelligent Technology professionally sells German NORIS Armaturen manual metering pumps, NORIS Armaturen gear pumps, NORIS Armaturen diaphragm pumps, NORIS Armaturen centrifugal pumps, NORIS Armaturen plunger pumps, NORIS Armaturen vacuum pumps, NORIS Armaturen screw pumps, NORIS Armaturen submersible pumps, NORIS Armaturen peristaltic pumps, NORIS Armaturen lubrication pumps, NORIS Armaturen vane pumps, NORIS Armaturen metering pumps, NORIS Armaturen manual pumps, NORIS Armaturen drum pumps, NORIS Armaturen lobe pumps, NORIS Armaturen booster pumps, NORIS Armaturen liquid pumps, NORIS Armaturen air pumps. Original German imports. Welcome inquiries and orders from users.