
German A Heinz KG submersible pump A Heinz KG model A Heinz KG price
A Heinz KG submersible pumps are important equipment for deep well water lifting. During operation, the entire unit is submerged in water to extract groundwater to the surface. They are used for domestic water supply, mine emergency rescue, industrial cooling, farmland irrigation, seawater lifting, ship ballast adjustment, and fountain landscapes. Hot water submersible pumps are used for hot spring bathing, suitable for extracting groundwater from deep wells, and for water lifting projects in rivers, reservoirs, and canals. They are mainly used for farmland irrigation and water supply for people and livestock in high mountain areas, and can also provide cooling for central air conditioning, heat pump units, chiller pump units, and drainage for cities, factories, railways, and mines.
- SKU
- _P004471187
- Category
- German-engineered pump, original imported
- Brand
- A Heinz KG
- Tags
- A Heinz KG submersible pump / Gear Pump / Diaphragm Pump / Centrifugal Pump / Plunger Pump / Vacuum Pump / Screw Pump
A Heinz KG submersible pump working principle
There are several types of submersible pumps; the motor windings can be oil-filled, water-filled, or dry-type. You must read the manual before use to avoid errors. If unused for a long period, the impeller must be rotated before operation to prevent seizure and winding burnout due to prolonged inactivity. Before starting the pump, the suction pipe and the pump interior must be filled with liquid. After starting, the impeller rotates at high speed, causing the liquid inside to rotate with the blades. Under centrifugal force, the liquid flies off the impeller and is discharged outward. The velocity of the discharged liquid gradually decreases in the diffusion chamber of the pump casing, while the pressure gradually increases, and then it flows out from the pump outlet and discharge pipe. At this time, a vacuum low-pressure zone without air or liquid is formed at the center of the blades because the liquid is thrown outward. Under the action of atmospheric pressure on the liquid surface, liquid from the sump flows into the pump through the suction pipe. In this way, liquid is continuously sucked up from the sump and continuously discharged from the discharge pipe.
A Heinz KG submersible pump mechanical structure
The submersible electric pump unit consists of four main parts: the water pump, the submersible motor (including cable), the water delivery pipe, and the control switch. The submersible pump is a single-suction multi-stage vertical centrifugal pump. The submersible motor is a sealed water-filled wet-type vertical three-phase squirrel-cage asynchronous motor. The motor and water pump are directly connected via a claw-type or single-key sleeve coupling. It is equipped with three-core cables of different specifications. The starting equipment includes air switches and auto-transformer reduced-voltage starters of different capacity ratings. The water delivery pipes are made of steel pipes with different diameters, connected using flanges. High-head electric pumps use gate valves for control. A labyrinth sand guard and two reverse-assembled skeleton oil seals are installed on the upper part of the submersible motor shaft to prevent flowing sand from entering the motor. The submersible motor uses water-lubricated bearings. The lower part is equipped with a rubber pressure-adjusting diaphragm and a pressure-adjusting spring, forming a pressure-adjusting chamber to regulate pressure changes caused by temperature. The motor windings use polyethylene insulation and nylon-sheathed water-resistant magnet wire. The cable connection follows cable joint procedures: remove the joint insulation, scrape off the varnish layer, connect separately, solder firmly, wrap with a layer of raw rubber, then wrap with 2-3 layers of waterproof adhesive tape, and finally cover with 2-3 layers of waterproof rubber tape or bond a layer of rubber (bicycle inner tube) with water-resistant glue to prevent water ingress. Each guide shell stage of the submersible pump contains a rubber bearing. The impeller is fixed to the pump shaft with a tapered sleeve. The guide shells are connected into one unit by threads or bolts. A check valve is installed at the upper part of high-head submersible pumps to prevent unit damage caused by water hammer during shutdown. The motor is sealed using precision spigot bolts, and the cable outlet is sealed with a rubber gasket. There is a water filling hole and an air vent hole at the upper end of the motor, and a drain hole at the lower part. Upper and lower thrust bearings are installed at the lower part of the motor. The thrust bearings have grooves for cooling and mate with a stainless steel thrust disc to withstand the axial forces of the water pump.
A Heinz KG submersible pump usage precautions
1) Install a residual current device (RCD): An RCD is also known as a life saver, and its function can be understood from this name. Since submersible pumps operate underwater, leakage can easily cause energy loss or even electric shock accidents. If an RCD is installed, it will cut off the power supply to the submersible pump whenever the leakage current exceeds the RCD's trip current value (generally not exceeding 30 mA), preventing energy waste due to leakage and ensuring safety. 2) Do not start if power voltage is abnormal: When low-voltage supply lines are long, excessively low voltage at the line end is common. When the phase voltage is below 198 V and the line voltage is below 342 V, the submersible pump motor speed drops. If it fails to reach 70% of the rated speed, the starting centrifugal switch will close, causing the starting winding to be energized for a long time, leading to overheating and even burnout of the winding and capacitor. Conversely, excessive voltage causes motor overheating and winding burnout. Therefore, during operation, the operator must monitor the power voltage. If it is more than 10% below the rated voltage or more than 10% above the rated voltage, the motor should be stopped to identify and rectify the fault. 3) Avoid frequent switching: Do not frequently switch the submersible pump on and off. When the electric pump stops, backflow occurs. Immediate restart causes the motor to start under load, resulting in excessive starting current that can burn out the windings. Due to the high starting current, frequent starts will also burn out the submersible pump motor windings. 4) Do not allow the submersible electric pump to operate under overload for long periods: To avoid long-term overload, do not pump water with high sand content, and monitor whether the current value is within the rating specified on the nameplate. If the current is too high, stop the pump for inspection. Additionally, the pump should not run dry for extended periods to prevent motor overheating and burnout. 5) Ensure correct motor rotation direction: Clarify the motor's rotation direction. While many types of submersible pumps can discharge water in both forward and reverse rotation, reverse rotation results in lower flow and higher current. Prolonged reverse rotation will damage the motor windings. 6) Cable installation and insulation resistance requirements for submersible electric pumps: When installing the submersible pump, keep the cable suspended and avoid excessive power cord length. Do not subject the cable to stress when lowering or lifting the pump to prevent power cord breakage. Do not allow the submersible pump to sink into mud during operation, as this will cause poor motor heat dissipation and burn out the motor windings. During installation, the motor's insulation resistance should not be less than 0.5 MΩ. 7) Inspect frequently and repair issues promptly: Regularly inspect the motor. If cracks are found in the lower cover, or if the rubber sealing ring is damaged or failed, replace or repair it immediately to prevent water ingress into the submersible pump.
Weidou Intelligent Technology professionally sells German A Heinz KG submersible pumps, A Heinz KG gear pumps, A Heinz KG diaphragm pumps, A Heinz KG centrifugal pumps, A Heinz KG piston pumps, A Heinz KG vacuum pumps, A Heinz KG screw pumps, A Heinz KG submersible pumps, A Heinz KG peristaltic pumps, A Heinz KG lubrication pumps, A Heinz KG vane pumps, A Heinz KG metering pumps, A Heinz KG hand pumps, A Heinz KG drum pumps, A Heinz KG lobe pumps, A Heinz KG booster pumps, A Heinz KG liquid pumps, A Heinz KG air pumps. Original German imports. Welcome inquiries and orders from users.






