German PULSOTRONIC sensors PULSOTRONIC models PULSOTRONIC prices
PULSOTRONIC sensors, also known as linear sensors, are metal-induction linear devices. The function of a sensor is to convert various measured physical quantities into electrical signals. In the production process, displacement measurement is generally divided into two types: measuring physical dimensions and mechanical displacement. According to the different forms of transformation of the measured variables, displacement sensors can be divided into analog and digital types. Analog types can be further divided into property-based and structural types. Commonly used displacement sensors are mostly analog structural types, including potentiometric displacement sensors, inductive displacement sensors, synchros,
- SKU
- _P004470743
- Category
- balluff sensor turck sensor in stock
- Brand
- PULSOTRONIC
- Tags
- Proximity Sensor / Displacement Sensor / Photoelectric Sensor / Process Sensors / Germany PULSOTRONIC
PULSOTRONIC sensor classification
1) Linear displacement sensor: The function of a linear displacement sensor is to convert linear mechanical displacement into an electrical signal. To achieve this effect, a variable resistor track is usually fixed at a stationary part of the sensor, and different resistance values are measured by the displacement of the wiper on the track. The sensor track is connected to a stable DC voltage, allowing a small current in the microampere range to flow. The voltage between the wiper and the starting end is proportional to the length of the wiper's movement. Using the sensor as a voltage divider minimizes the requirement for the accuracy of the total resistance of the track, because resistance changes caused by temperature variations do not affect the measurement result.
2) Angular displacement sensor: Angular displacement sensors are applied in obstacle handling: using an angle sensor to control your wheels can indirectly detect obstacles. The principle is very simple: if the motor angle sensor is operating but the gear does not rotate, it indicates that your machine is blocked by an obstacle. This technology is very simple to use and highly effective; the only requirement is that the moving wheel must not slip on the floor (or slip too frequently), otherwise you will not be able to detect obstacles. Connecting an idler gear to the motor can avoid this problem; this wheel is not driven by the motor but is driven by the movement of the device: during the rotation of the drive wheel, if the idler wheel stops, it indicates that you have encountered an obstacle.
Precautions for using PULSOTRONIC sensors
1) If the electronic ruler has been used for a long time, and the seal has aged while accumulating many impurities, water mixtures and oil will seriously affect the contact resistance of the brush, causing the displayed numbers to jump continuously. In this case, it can be said that the electronic ruler of the linear displacement sensor is damaged and needs to be replaced.
2) If the power supply capacity is too small, many issues may arise; therefore, the power supply must have sufficient capacity. Insufficient capacity will cause the following situations: the movement of the plasticizing unit will cause fluctuations in the display of the mold clamping electronic ruler, or the mold clamping movement will cause fluctuations in the display of the injection molding electronic ruler, resulting in large measurement errors. If the driving power supply of the solenoid valve is combined with the power supply of the linear displacement sensor, the above situations are more likely to occur. In severe cases, voltage fluctuations can even be measured using the voltage range of a multimeter. If the situation is not caused by high-frequency interference, electrostatic interference, or poor neutral grounding, it is likely due to insufficient power supply capacity.
3) Frequency modulation interference and electrostatic interference can both cause the displayed numbers on the electronic ruler of the linear displacement sensor to jump. The signal cables of the electronic ruler must be routed in separate cable trays from the high-voltage lines of the equipment. The electronic ruler must mandatorily use a grounding bracket, and ensure good contact between the housing of the electronic ruler and the ground. Shielded cables must be used for signal lines, and one end of the shielded cable should be grounded at the electrical cabinet.
When there is high-frequency interference, voltage measurements with a multimeter usually appear normal, but the displayed numbers will keep jumping; when electrostatic interference occurs, the situation is similar to high-frequency interference. To verify whether it is electrostatic interference, you can short-circuit the cover screw of the electronic ruler to some metal part of the machine using a piece of power cable. Once short-circuited, the electrostatic interference will be eliminated immediately. However, it is difficult to eliminate high-frequency interference using the above method. Variable frequency drives and robotic arms often generate high-frequency interference, so you can try stopping the high-frequency drive or the robotic arm to verify if it is high-frequency interference.
4) If the display data of the electronic ruler of the linear displacement sensor jumps regularly at a certain point during operation, or if there is no display data, check whether the insulation of the connection cable is damaged and causing a regular short circuit to ground due to contact with the machine housing.
5) The supply voltage must be stable. Industrial voltage requires stability within ±0.1[%]. For example, if the reference voltage is 10V, a fluctuation of ±0.01V is allowed. Otherwise, it will cause significant fluctuations in the display.
However, if the amplitude of the display fluctuation does not exceed the amplitude of the voltage fluctuation, the electronic ruler is functioning normally.
6) The alignment of the linear displacement sensor installation must be good, but parallelism allows an error of ±0.5mm, and angular alignment allows an error of ±12°. However, if both parallelism and angular errors are too large, the displayed numbers will jump. In such cases, the parallelism and angle must be adjusted.
7) During the connection process, pay close attention. The three wires of the electronic ruler must not be connected incorrectly, and the power line and output line must not be swapped. If the wires are connected incorrectly, it will result in large linear errors, making control difficult and reducing control precision, while the display is prone to jumping phenomena.
PULSOTRONIC sensor applications
The geometric state parameters of train wheel flanges affect the speed and smoothness of train operation and are crucial for safe train operation. Traditional detection methods are relatively complex, usually involving measurement with specialized calipers, leading to significant errors due to manual data reading, and preventing digital management of detection data. With the development of China's railway industry, train speeds are increasing, making precise and rapid inspection and digital management of train wheel flange state parameters increasingly important. The flange detector adopts modern sensor technology, a microcontroller processing system, and a concise and stable mechanical structure, enabling convenient and precise continuous rapid measurement of geometric state parameters, achieving digitization of parameters such as flange height and rim thickness.
Many sensors are used for detecting flange height, width, rim thickness, etc., with displacement sensors being the most concerned. There are many types of displacement sensors; the currently new sensor technology used for train wheel flange shape detection is called laser displacement sensors. Currently, the laser triangulation method is used for train wheel flange detection, offering high precision for short-distance measurements. The displacement sensor can be directly installed on the track for detection, or a laser reflective displacement sensor can be used as the measuring device. The laser sensor module scans the flange shape along a straight line direction while recording the entire flange data. The entire flange contour curve can be derived via a microprocessor, thereby calculating flange width, flange height, 70mm wear amount, and wear area, etc. Furthermore, the measured data can be uploaded to a computer to generate a database, utilizing advanced post-processing software for digital management of train wheel flanges. It can not only measure wheelset wear on trains in online operation but also sort wheelsets on the production line based on whether their dimensions are qualified.
The development of transportation relies on detection technology, and instruments, meters, and sensor technology are the core of detection technology. In today's era of rapid power development, people not only hope to experience comfort and enjoyment but also desire safety. The development of sensor technology will bring more safety to people's lives and transportation, and the development of sensor technology in China will also drive the development of world-class advanced technologies in the transportation sector internationally.
Weidou Intelligent Technology specializes in selling German PULSOTRONIC sensors, PULSOTRONIC proximity sensors, PULSOTRONIC distance sensors, PULSOTRONIC vision sensors, PULSOTRONIC displacement sensors, PULSOTRONIC torque sensors, PULSOTRONIC speed sensors, PULSOTRONIC photoelectric sensors, PULSOTRONIC position sensors, PULSOTRONIC angle sensors, PULSOTRONIC tactile sensors, PULSOTRONIC temperature sensors, PULSOTRONIC pressure sensors, PULSOTRONIC flow sensors, PULSOTRONIC level sensors, PULSOTRONIC motion sensors, PULSOTRONIC process sensors. Original imports from Germany. Welcome customers to inquire and order.