Weidou Intelligent Technology (Shanghai) Co., Ltd.
中文
WDUTECH industrial automation products and services
Categories and filters

Home/Products/ balluff sensor turck sensor in stock

German Pfeiffer Vacuum sensors, Pfeiffer Vacuum models, Pfeiffer Vacuum prices

German Pfeiffer Vacuum sensors, Pfeiffer Vacuum models, Pfeiffer Vacuum prices

Pfeiffer Vacuum sensors generally consist of 2 parts: the processing path and the processing element. The basic principle is based on the photoelectric effect, converting changes in the measured quantity into changes in optical signals, and then using photoelectric elements to further convert non-electrical signals into electrical signals. The photoelectric effect refers to illuminating an object with light, which can be viewed as a stream of photons with specific energy bombarding the object. At this time, the photon energy is transferred to electrons, and the entire energy of one photon is absorbed by one electron at once. The electron receives the energy transmitted by the photon.

SKU
_P004470726
Category
balluff sensor turck sensor in stock
Tags
Proximity Sensor / Displacement Sensor / Photoelectric Sensor / Process Sensors / Germany Pfeiffer Vacuum
Pfeiffer Vacuum sensors generally consist of 2 parts: the processing path and the processing element. The basic principle is based on the photoelectric effect, converting changes in the measured quantity into changes in optical signals, and then using photoelectric elements to further convert non-electrical signals into electrical signals. The photoelectric effect refers to illuminating an object with light, which can be viewed as a stream of photons with specific energy bombarding the object. At this time, the photon energy is transferred to electrons, and the entire energy of one photon is absorbed by one electron at once. After receiving the energy transmitted by the photon, the state of the electron changes, causing the illuminated object to produce a corresponding electrical effect. The photoelectric effect is usually divided into 3 categories: (1) The phenomenon where electrons escape from the surface of an object under the action of light is called the external photoelectric effect, such as in phototubes and photomultiplier tubes; (2) The phenomenon where the resistivity of an object changes under the action of light is called the internal photoelectric effect, such as in photoresistors and phototransistors; (3) The phenomenon where an object generates an electromotive force in a certain direction under the action of light is called the photovoltaic effect, such as in photocells.


Pfeiffer Vacuum sensor classification


Load cells are divided into 8 types based on conversion methods: photoelectric, hydraulic, electromagnetic force, capacitive, magnetic pole variation, vibratory, gyroscope, and resistance strain gauge types, with resistance strain gauge types being the most widely used. 1) Photoelectric type: Includes grating and code disk types. Grating sensors use Moiré fringes formed by gratings to convert angular displacement into photoelectric signals. There are two gratings: one fixed grating and one moving grating mounted on the dial shaft. The measured object placed on the weighing platform rotates the dial shaft through the force transmission lever system, driving the moving grating to rotate and causing the Moiré fringes to move. Using a phototube, conversion circuit, and display instrument, the number of moved Moiré fringes can be calculated to measure the angle of grating rotation, thereby determining and reading the mass of the measured object. Code disk sensors: The code disk (symbol plate) is a piece of transparent glass mounted on the dial shaft, featuring black and white codes arranged according to a specific encoding method. When the measured object on the weighing platform rotates the dial shaft via the force transmission lever, the code disk also rotates by a certain angle. A photocell receives the light signal passing through the code disk and converts it into an electrical signal, which is then digitally processed by the circuit, finally displaying the digital value representing the measured mass on the display. Photoelectric sensors were mainly used in electromechanical combination scales. 2) Hydraulic type: Under the action of the gravity P of the measured object, the pressure of the hydraulic oil increases, with the degree of increase proportional to P. By measuring the increased pressure value, the mass of the measured object can be determined. Hydraulic sensors have a simple and robust structure and a large measurement range, but the accuracy generally does not exceed 1/100. 3) Capacitive type: It operates based on the proportional relationship between the oscillation frequency f of the capacitor oscillator circuit and the distance d between the plates. There are two plates: one is fixed, and the other is movable. When the measured object is loaded onto the weighing platform, the leaf spring deflects, changing the distance between the two plates, which in turn changes the oscillation frequency of the circuit. By measuring the change in frequency, the mass of the measured object on the weighing platform can be calculated. Capacitive sensors consume little power, have low cost, and offer an accuracy of 1/200 to 1/500.


Pfeiffer Vacuum sensor features


Resistors, inductors, and capacitors are the three major types of passive components in electronics. A capacitive sensor is a sensor that converts changes in the measured quantity into changes in capacitance; it is essentially a capacitor with variable parameters. Capacitive sensors have the following advantages: high impedance, low power, and requiring only very low input energy. They can achieve large changes, resulting in high signal-to-noise ratio and system stability. Fast dynamic response, with operating frequencies reaching several megahertz. Non-b contact measurement; the measured object can be either a conductor or a semiconductor. Simple structure and strong adaptability, allowing operation in harsh environments such as high/low temperatures and strong radiation, leading to wide application. With the development of electronic technology and computer technology, disadvantages of capacitive sensors, such as susceptibility to interference and distributed capacitance, have been continuously overcome. Furthermore, capacitive grid displacement sensors and integrated capacitive sensors have been developed. Therefore, they are widely used in non-electrical quantity measurement and automatic detection, capable of measuring parameters such as pressure, displacement, speed, acceleration, Aness, thickness, liquid level, humidity, vibration, and component content. Capacitive sensors have good development prospects.


Pfeiffer Vacuum sensor installation precautions


1) Handle load cells with care, especially small-capacity sensors using aluminum alloy as the elastic body. Any impact or drop caused by vibration is likely to cause significant output errors. 2) When designing the loading device and during installation, ensure that the axis of the applied load coincides with the force axis of the load cell to minimize the effects of inclined and eccentric loads. 3) Regarding level adjustment: If using a load cell, adjust the installation plane of its base with a spirit level until it is horizontal. If multiple sensors are used for simultaneous measurement, their base installation surfaces should be kept as level as possible. The main purpose of this is to ensure that the force borne by each sensor is basically consistent. 4) Determine the rated load of the sensor used based on the load cell capacity selection specified in its instructions. 5) To prevent chemical corrosion, apply Vaseline to the outer surface of the load cell during installation. Avoid direct sunlight and environments with drastic temperature changes. 6) Install bypasses made of copper braided wire at both ends of the load cell loading device. 7) Do not extend the cable yourself. If extension is absolutely necessary, solder the joints and apply moisture-proof sealant. 8) It is best to use baffles to cover the sensor around the load cell. This prevents debris from falling into the moving parts of the sensor, which could affect its measurement accuracy. 9) Keep the sensor cable away from high-power power lines or places with pulse waves. If avoidance is impossible, run the load cell cable separately through an iron pipe and shorten the connection distance as much as possible. 10) Determine the rated load of the sensor used based on the load cell capacity selection specified in its instructions. Although load cells have a certain overload capacity, avoid such situations during installation and use. Even short-term overloading may cause permanent damage to the sensor. 11) For high-precision applications, allow the load cell and instrument to warm up for 30 minutes before use.



Weidou Intelligent Technology specializes in selling German Pfeiffer Vacuum sensors, Pfeiffer Vacuum proximity sensors, Pfeiffer Vacuum distance sensors, Pfeiffer Vacuum vision sensors, Pfeiffer Vacuum displacement sensors, Pfeiffer Vacuum torque sensors, Pfeiffer Vacuum speed sensors, Pfeiffer Vacuum photoelectric sensors, Pfeiffer Vacuum position sensors, Pfeiffer Vacuum angle sensors, Pfeiffer Vacuum tactile sensors, Pfeiffer Vacuum temperature sensors, Pfeiffer Vacuum pressure sensors, Pfeiffer Vacuum flow sensors, Pfeiffer Vacuum level sensors, Pfeiffer Vacuum motion sensors, and Pfeiffer Vacuum process sensors. Original German imports. Welcome inquiries and orders from users.




Recommended products