German MESSKO sensors, MESSKO models, MESSKO prices
MESSKO sensors are sensors that measure the operating speed of the measured object and convert it into an output signal. Speed sensors include linear speed sensors and rotational speed sensors. With technological development, traditional measurement equipment can no longer meet current needs and is gradually being phased out, while laser speed sensors are widely used. They play an important role in product manufacturing processes; by connecting to a computer, they enable automated and intelligent measurement control of the measured object. This is the product of the combination of modern measurement technology and computer technology. M
- SKU
- _P004470680
- Category
- balluff sensor turck sensor in stock
- Brand
- MESSKO
- Tags
- Proximity Sensor / Displacement Sensor / Photoelectric Sensor / Process Sensors / Germany MESSKO
MESSKO sensor classification
Load cells are classified into 8 types based on conversion methods, including photoelectric, hydraulic, electromagnetic force, capacitive, magnetic pole variation, vibratory, gyroscopic, and resistive strain gauge types, with resistive strain gauge types being the most widely used. 1) Photoelectric type: Includes grating and code disk types. Grating sensors use Moiré fringes formed by gratings to convert angular displacement into photoelectric signals. There are two gratings: one fixed grating and one moving grating mounted on the dial shaft. The measured object placed on the load-bearing platform rotates the dial shaft through the force transmission lever system, driving the moving grating to rotate and causing the Moiré fringes to move. By using phototubes, conversion circuits, and display instruments, the number of moved Moiré fringes can be calculated to determine the angle of grating rotation, thereby determining and reading the mass of the measured object. Code disk sensors: A code disk (symbol plate) is a piece of transparent glass mounted on the dial shaft, featuring black and white codes arranged according to a specific encoding method. When the measured object on the load-bearing platform rotates the dial shaft via the force transmission lever, the code disk also rotates by a certain angle. Photocells receive light signals passing through the code disk and convert them into electrical signals, which are then digitally processed by the circuit, finally displaying the digital value representing the measured mass on the display. Photoelectric sensors were mainly used in electromechanical combination scales. 2) Hydraulic type: Under the action of the gravity P of the measured object, the pressure of the hydraulic oil increases, with the increase proportional to P. By measuring the increased pressure value, the mass of the measured object can be determined. Hydraulic sensors have a simple and robust structure and a large measurement range, but accuracy generally does not exceed 1/100. 3) Capacitive type: It operates based on the proportional relationship between the oscillation frequency f of the capacitor oscillator circuit and the distance d between the plates. There are two plates, one fixed and the other movable. When the measured object is loaded onto the load-bearing platform, the leaf spring deflects, changing the distance between the two plates, which in turn changes the oscillation frequency of the circuit. By measuring the change in frequency, the mass of the measured object on the load-bearing platform can be calculated. Capacitive sensors consume little power, have low cost, and offer an accuracy of 1/200 to 1/500.
MESSKO sensor features
Resistors, inductors, and capacitors are the three major types of passive components in electronics. Capacitive sensors convert changes in the measured quantity into changes in capacitance; essentially, they are capacitors with variable parameters. Capacitive sensors offer the following advantages: high impedance, low power consumption, and requiring only very low input energy. They can achieve large change magnitudes, resulting in high signal-to-noise ratios and system stability. They have fast dynamic response, with operating frequencies reaching several megahertz, supporting non-b contact measurement, suitable for both conductive and semiconductor measured objects. They have a simple structure and strong adaptability, capable of operating in harsh environments such as high/low temperatures and strong radiation, leading to wide application. With the development of electronic and computer technologies, disadvantages of capacitive sensors, such as susceptibility to interference and distributed capacitance, have been continuously overcome. Furthermore, capacitive grid displacement sensors and integrated capacitive sensors have been developed. Therefore, they are widely used in non-electrical quantity measurement and automatic detection, capable of measuring parameters such as pressure, displacement, speed, acceleration, A degree, thickness, liquid level, humidity, vibration, and component content. Capacitive sensors have promising development prospects.
MESSKO sensor installation precautions
1) Handle load cells with care, especially small-capacity sensors using aluminum alloy as the elastic body. Any impact or drop caused by vibration is likely to cause significant output errors.
2) When designing the loading device and during installation, ensure that the line of action of the loading force coincides with the force axis of the load cell to minimize the effects of inclined and eccentric loads.
3) Regarding level adjustment: If using a load cell, adjust the installation plane of its base with a spirit level until it is horizontal. If multiple sensors are used for simultaneous measurement, their base installation surfaces should be kept as level as possible to ensure that the force borne by each sensor is basically consistent.
4) Determine the rated load of the sensor used based on the load cell capacity selection specified in its instructions.
5) To prevent chemical corrosion, apply Vaseline to the outer surface of the load cell during installation. Avoid direct sunlight and environments with drastic temperature changes.
6) Install bypasses made of copper braided wire at both ends of the load cell loading device.
7) Do not extend the cable yourself. If extension is absolutely necessary, solder the joints and apply moisture-proof sealant.
8) It is best to use baffles to cover the sensor around the load cell. This prevents debris from falling into the moving parts of the sensor, affecting its measurement accuracy.
9) Keep the sensor cables away from high-power power lines or areas with pulse waves. If avoidance is impossible, route the load cell cables separately through iron pipes and shorten the connection distance as much as possible.
10) Determine the rated load of the sensor used based on the load cell capacity selection specified in its instructions. Although load cells have a certain overload capacity, avoid such situations during installation and use. Even short-term overloading may cause permanent damage to the sensor.
11) For high-precision applications, allow the load cell and instrument to warm up for 30 minutes before use.
Weidou Intelligent Technology specializes in selling German MESSKO sensors, MESSKO proximity sensors, MESSKO distance sensors, MESSKO vision sensors, MESSKO displacement sensors, MESSKO torque sensors, MESSKO speed sensors, MESSKO photoelectric sensors, MESSKO position sensors, MESSKO angle sensors, MESSKO tactile sensors, MESSKO temperature sensors, MESSKO pressure sensors, MESSKO flow sensors, MESSKO level sensors, MESSKO motion sensors, and MESSKO process sensors. Original German imports. Welcome inquiries and orders from users.