Weidou Intelligent Technology (Shanghai) Co., Ltd.
中文
WDUTECH industrial automation products and services
Categories and filters

Home/Products/ moog valve rexroth valve

German roquet valves roquet models roquet prices

German roquet valves roquet models roquet prices

roquet valves are valves that reduce inlet pressure to a required outlet pressure through regulation, and rely on the energy of the medium itself to automatically maintain stable outlet pressure. From the perspective of fluid mechanics, a pressure reducing valve is a throttling element with variable local resistance, i.e., by changing the throttling area, the flow velocity and kinetic energy of the fluid are changed, causing different pressure losses, thereby achieving pressure reduction. Then, relying on the regulation of the control and adjustment system, the fluctuation of the pressure downstream of the valve is balanced with the spring force, keeping the downstream pressure constant within a certain error range. r

SKU
_P004469060
Category
moog valve rexroth valve
Tags
Valves / Control Valve / Solenoid Valve / Safety Valve / Globe Valve / roquet valves
roquet valves are valves that reduce inlet pressure to a required outlet pressure through regulation, and rely on the energy of the medium itself to automatically maintain stable outlet pressure. From the perspective of fluid mechanics, a pressure reducing valve is a throttling element with variable local resistance, i.e., by changing the throttling area, the flow velocity and kinetic energy of the fluid are changed, causing different pressure losses, thereby achieving pressure reduction. Then, relying on the regulation of the control and adjustment system, the fluctuation of the pressure downstream of the valve is balanced with the spring force, keeping the downstream pressure constant within a certain error range.


roquet valve operating principle


A pressure reducing valve reduces water pressure by the local resistance of the flow channel inside the valve to the water flow. The range of water pressure drop is automatically regulated by the water pressure difference between the inlet and outlet on both sides of the diaphragm or piston connected to the valve disc. The fixed-ratio pressure reduction principle utilizes the water pressure ratio control of the floating piston in the valve body; the pressure reduction ratio between the inlet and outlet ends is inversely proportional to the area ratio of the pistons on the inlet and outlet sides. This pressure reducing valve operates smoothly without vibration; there is no spring inside the valve body, so there is no concern about spring corrosion or metal fatigue failure; the sealing performance is good with no leakage, thus reducing both dynamic pressure (when water is flowing) and static pressure (when flow rate is 0); especially, it reduces pressure without affecting the water flow rate. A pressure reducing valve regulates the flow rate of the medium by controlling the opening degree of the closing member inside the valve body, reducing the pressure of the medium, while simultaneously adjusting the opening degree of the closing member by the action of the pressure downstream of the valve, keeping the downstream pressure within a certain range, and injecting cooling water inside the valve body or downstream of the valve to reduce the temperature of the medium; this type of valve is called a pressure reducing and temperature reducing valve. Kuaiyiyou Automation Selection includes pressure reducing valves. The characteristic of this valve is to maintain the outlet pressure and temperature values within a certain range when the inlet pressure changes continuously.


roquet valve installation precautions


1) Before installing the valve, carefully verify whether the model and specifications of the valve used match the design; 2) Check against the valve model and factory instruction manual to determine if the valve can be applied under the required conditions; 3) When lifting the valve, the rope should be tied at the flange connection between the valve body and the valve cover, and must not be tied to the handwheel or valve stem, to avoid damaging the valve stem and handwheel; 4) When installing the valve on a horizontal pipe, the valve stem should be vertically upward; downward installation of the valve stem is not allowed; 5) When installing the valve, do not use forced alignment connection methods involving pulling or dragging, to avoid damage caused by uneven stress; 6) Rising stem gate valves should not be installed in underground damp locations to avoid corrosion of the valve stem.


roquet valve troubleshooting


In certain pressure reducing control circuits, the outlet pressure of the pressure reducing valve is used to control the control oil pressure of electro-hydraulic directional valves or externally controlled sequence valves, etc. When the electro-hydraulic directional valve or externally controlled sequence valve reverses or operates, the flow rate at the outlet of the pressure reducing valve becomes zero, but the pressure must still maintain the originally set pressure. In this case, since the outlet flow rate of the valve is zero, the flow rate passing through the pressure reducing port is only the pilot flow. Since the pilot flow is very small, generally within 2L/min, the main valve pressure reducing port is basically close to the fully closed position (extremely small opening), and the pilot flow flows out from the triangular groove or inclined conical surface. If the fit of the main valve spool is too loose or the wear is excessive, the leakage increases. According to the continuity theorem of flow, this part of the leakage must also flow from the damping hole of the main valve spool, i.e., the flow through the damping hole consists of two parts: the pilot flow and the leakage. Since the area of the damping hole and the oil pressure in the main valve spring chamber remain unchanged (the oil pressure in the spring chamber is determined by the pre-compression amount of the adjusted pressure regulating spring), to increase the flow through the damping hole, the oil pressure in the lower chamber of the main valve will inevitably rise. Therefore, after the outlet pressure of the pressure reducing valve is set, if the outlet flow rate is zero, the outlet pressure will rise due to the loose fit or excessive wear of the main valve spool.



Weidou Intelligent Technology professionally sells German roquet valves, roquet safety valves, roquet globe valves, roquet control valves, roquet solenoid valves, roquet ball valves, roquet proportional valves, roquet diaphragm valves, roquet butterfly valves, roquet hydraulic transmission valves, roquet check valves, roquet pressure reducing valves, roquet relief valves, roquet sequence valves, roquet balance valves, roquet throttle valves, roquet directional valves, original German imports. Welcome customers to inquire and order.




Recommended products