Weidou Intelligent Technology (Shanghai) Co., Ltd.
中文
WDUTECH industrial automation products and services
Categories and filters

Home/Products/ moog valve rexroth valve

German Axel Larsson valves, Axel Larsson models, Axel Larsson prices

German Axel Larsson valves, Axel Larsson models, Axel Larsson prices

Axel Larsson valves are electromagnetically controlled industrial devices. They are basic automation components for fluid control, classified as actuators, and are not limited to hydraulic or pneumatic applications. They are used in industrial control systems to adjust media direction, flow rate, speed, and other parameters. Solenoid valves can be combined with different circuits to achieve desired control, ensuring precision and flexibility. There are many types of solenoid valves, each serving different functions at various positions in the control system; the most common types include check valves, safety valves, directional control valves, and speed control valves. A

SKU
_P004464740
Category
moog valve rexroth valve
Tags
Valves / Control Valve / Solenoid Valve / Safety Valve / Globe Valve / Axel Larsson valve
Axel Larsson valves are electromagnetically controlled industrial devices. They are basic automation components for fluid control, classified as actuators, and are not limited to hydraulic or pneumatic applications. They are used in industrial control systems to adjust media direction, flow rate, speed, and other parameters. Solenoid valves can be combined with different circuits to achieve desired control, ensuring precision and flexibility. There are many types of solenoid valves, each serving different functions at various positions in the control system; the most common types include check valves, safety valves, directional control valves, and speed control valves.


Axel Larsson valve operating principle


The solenoid valve contains a sealed chamber with ports opened at different positions, each connected to different oil pipes. A piston is located in the center of the chamber, with two electromagnets on either side. When the coil of one magnet is energized, the valve body is attracted to that side. By controlling the movement of the valve body, different oil discharge ports are opened or closed, while the oil inlet port remains normally open. Hydraulic oil enters different discharge pipes, and the oil pressure pushes the cylinder piston, which in turn drives the piston rod and the mechanical device. Thus, mechanical motion is controlled by switching the current to the electromagnets on and off.


Axel Larsson valve routine maintenance


1) Pay attention to the valve storage environment; it should be stored in a dry, ventilated indoor space, with both ends of the flow path blocked. 2) Valves should be inspected regularly; remove dirt and apply anti-rust oil to the surface. 3) Valves that have been installed and applied should undergo regular maintenance to ensure normal operation. 4) Check whether the valve sealing surface is worn, and repair or replace it as necessary. 5) Check the wear condition of the trapezoidal threads on the valve stem and valve stem nut, and whether the packing is outdated or failed, and perform necessary replacements. 6) Test the sealing performance of the valve to ensure its integrity. 7) Valves in operation should be in good condition, with all bolts on flanges and supports complete, threads undamaged, and no looseness. 8) If the handwheel is lost, it should be replaced promptly; do not use an adjustable wrench as a substitute. 9) The packing gland must not be skewed or lack pre-tightening clearance. 10) If the valve operating environment is harsh and prone to contamination by rain, snow, dust, sand, etc., a protective cover should be installed on the valve stem. 11) The scale on the valve should remain complete, accurate, and clear; check the valve lead seal and cap. 12) The insulation jacket should have no dents or cracks. 13) Avoid striking valves in operation or supporting heavy weights on them.


Axel Larsson valve classification


Solenoid valves are divided into three main categories based on their operating principle: 1) Direct-acting solenoid valve. Principle: When energized, the electromagnetic coil generates electromagnetic force that lifts the closing member from the valve seat, opening the valve; when de-energized, the electromagnetic force disappears, and the spring presses the closing member against the valve seat, closing the valve. Features: It can operate normally under vacuum, negative pressure, and zero pressure conditions, but the nominal diameter generally does not exceed 25mm. 2) Step-by-step direct-acting solenoid valve. Principle: It combines direct-acting and pilot-operated principles. When there is no pressure difference between the inlet and outlet, energizing the valve causes the electromagnetic force to lift the pilot small valve and the main valve closing member sequentially, opening the valve. When the pressure difference between the inlet and outlet reaches the starting differential pressure, energizing the valve activates the pilot small valve; the pressure in the lower chamber of the main valve rises, and the pressure in the upper chamber drops, using the pressure difference to push the main valve open. When de-energized, the pilot valve uses spring force or media pressure to push the closing member downward, closing the valve. Features: It can operate reliably under zero pressure difference, vacuum, or high pressure conditions, but has higher power consumption and requires horizontal installation. 3) Pilot-operated solenoid valve. Principle: When energized, the electromagnetic force opens the pilot hole, causing the pressure in the upper chamber to drop rapidly. A pressure difference (lower above, higher below) forms around the closing member, and fluid pressure pushes the closing member upward, opening the valve. When de-energized, the spring force closes the pilot hole. Inlet pressure rapidly enters the chamber through the bypass hole, forming a pressure difference (higher above, lower below) around the closing member, and fluid pressure pushes the closing member downward, closing the valve. Features: The upper limit of the fluid pressure range is relatively high, and it can be installed in any orientation (customization required), but fluid pressure difference conditions must be met.



Weidou Intelligent Technology specializes in selling German Axel Larsson valves, Axel Larsson safety valves, Axel Larsson globe valves, Axel Larsson control valves, Axel Larsson solenoid valves, Axel Larsson ball valves, Axel Larsson proportional valves, Axel Larsson diaphragm valves, Axel Larsson butterfly valves, Axel Larsson hydraulic transmission valves, Axel Larsson check valves, Axel Larsson pressure reducing valves, Axel Larsson relief valves, Axel Larsson sequence valves, Axel Larsson balance valves, Axel Larsson throttle valves, Axel Larsson directional valves. Original German imports. Welcome customers to inquire and order.