Weidou Intelligent Technology (Shanghai) Co., Ltd.
中文
WDUTECH industrial automation products and services
Categories and filters

Home/Products/ schmersal switch pilz switch in stock

pilz safety relay 750103 750104 special price in stock

pilz safety relay 750103 750104 special price in stock

pilz safety relay 750103 750104 is composed of several relays and circuits to complement each other's abnormal defects, achieving correct and low false-operation relay functionality. This minimizes errors and failures, thereby increasing safety factors. Various safety relays are designed to protect machinery of different levels, with the main goal of protecting machine operators exposed to varying degrees of hazard. pilz safety relay 750103 750104 is used for inputs that confirm machine safety; after confirmation,

SKU
_P004455818
Category
schmersal switch pilz switch in stock


pilz safety relay 750103 750104 is composed of several relays and circuits to complement each other's abnormal defects, achieving correct and low false-operation relay functionality. This minimizes errors and failures, thereby increasing safety factors. Various safety relays are designed to protect machinery of different levels, with the main goal of protecting machine operators exposed to varying degrees of hazard. pilz safety relay 750103 750104 is used for inputs that confirm machine safety; after confirmation, it is applied in the design of safety circuits controlling inputs to contactors and other devices. Weidou Intelligent Technology supplies pilz safety relay 750103 750104 at special prices, with stock available in Shanghai.


pilz safety relay 750103 750104 description

Model: PNOZ s3 24VDC 2 n/o  750103

PNOZ sigma safety relay (standalone). Input: 1- / 2 channel wiring, with/without contact short-circuit detection. Output: 2 N / O, 1 semiconductor(s). UB 24 V DC, width: 17.5 mm, screw-type plug-in terminals for monitoring emergency stops and safety gates.

piz relay technology 750103 parameters:

Certificates: CE, cULus certification, EAC (Eurasian), TÜV, KOSHA, CCC

Application options: Instantaneous emergency stop monitoring, limit switches, light curtain device monitors. Category 2, typical value, light curtain device monitor. Category 2, non-typical, light curtain device monitor. Category 4, safety gate monitoring, operating mode: Single-channel, automatic reset, dual-channel, manual reset, inter-contact short-circuit detection, start test, manual reset monitoring, no inter-contact short-circuit detection, self-test, product standard: EN 60947-5-1, standard: EN 60204-1, EN 62061, EN ISO 13849-1, VDE 0113-1,Supply voltage (V): 24,0, power type: DC, terminal type: Plug-in, terminal type: Screw terminals, number of instantaneous safety contacts: 2, number of delayed safety contacts: 0,Number of auxiliary contacts: 0, number of semiconductor outputs: 1, stop category: 0, maximum current I at DC13 (6 cycles/min): 5.0 A, maximum current 5 at AC1: 5.0 A, width: 17.5 mm, height: 98.0 mm, pilz safety relay 750103 750104 depth: 120.0 mm, total weight: 150 g, net weight: 140 g, ambient temperature in degrees Celsius: -10 - 55 °C。


Model: PNOZ s4 24VDC 3 n/o 1 n/c 750104

PNOZsigma safety relay (standalone). Inputs: 1- / 2 channel wiring, with/without contact short-circuit detection. Outputs: 3 N / O, 1 N / C, 1 semiconductor(s). UB 24 V DC, width: 22.5 mm, screw-type plug-in terminals for monitoring E-stop and safety gates.

piz relay 750104 technical specifications:

Certificates: CE, cULus certification, EAC (Eurasian), TÜV, KOSHA, CCC, application options: Instantaneous E-stop monitoring, limit switches, light curtain device monitor. Category 2, typical value, light curtain device monitor. Category 2, non-typical, light curtain device monitor. Category 4, safety gate monitoring,Operating mode: Single-channel, automatic reset, dual-channel, manual reset, inter-contact short-circuit detection, start test, manual reset monitoring, no inter-contact short-circuit detection, self-test, product standard: EN 60947-5-1, standard: EN 60204-1, EN 62061, EN ISO 13849-1, VDE 0113-1,Supply voltage (V): 24,0, power type: DC, terminal type: Plug-in, terminal type: Screw terminals, number of instantaneous safety contacts: 3, number of delayed safety contacts: 0, number of auxiliary contacts: 1, number of semiconductor outputs:1, stop category: 0, maximum current I at DC13 (6 cycles/min): 5.0 A, maximum current 5 at AC1: 5.0 A, width: 22.5 mm, height: 98.0 mm, depth: 120.0 mm, pilz safety relay 750103 750104 total weight: 195 g, net weight: 185 g, ambient temperature in degrees Celsius: -10 - 55 °C。


pilz safety relay 750103 750104 common specifications and models

pilz safety relay 750101 PNOZ s1 24DC 2NA+1pnp

pilz safety relay 750102 PNOZ s2 24DC 3NA+1NC+1pnp

pilz safety relay 750103 PNOZ s3 24DC 2NA+1pnp

pilz safety relay 750104 PNOZ s4 24DC 3NA+1NC+1pnp

pilz safety relay 750105 PNOZ s5 24DC 2NA+2NA(R)+1pnp

pilz safety relay 750106 PNOZ s6 24DC 3NA+1NC+1pnp

pilz safety relay 750107 PNOZ s7 24DC 4NA+1NC

pilz safety relay 750108 PNOZ s8 24DC 2NA+1pnp

pilz safety relay 750109 PNOZ s9 24DC 3NA+1NC

pilz safety relay 750110 PNOZ s10 24DC 4NA+1NC

pilz safety relay 750111 PNOZ s11 24DC 8NA+1NC

pilz safety relay 750124 PNOZ s4.1 24DC 3NA+1NC+1pnp

pilz safety relay 750126 PNOZ s6.1 24DC 3NA+1NC+1pnp

pilz safety relay 750132 PNOZ s22 (3NA+1NC) x 2

pilz safety relay 750134 PNOZ s4 48..240AC/DC 3NA+1NC+1pnp

pilz safety relay 750135 PNOZ s5 48..240AC/DC2NA+2NA(R)+1pnp

pilz safety relay 750136 PNOZ s6 48..240AC/DC 3NA+1NC+1pnp

pilz safety relay 750154 PNOZ s4.1 48..240AC/DC 3NA+1NC+1pnp

pilz safety relay 750156 PNOZ s6.1 48..240AC/DC 3NA+1NC+1pnp

pilz safety relay 750160 PNOZ s20 24DC  2 uscite pnp

pilz safety relay 750167 PNOZ s7.1 24DC 3NA

pilz safety relay 750177 PNOZ s7.2 24DC  4NA+1NC

pilz safety relay 750330 PNOZ s30 24...240 VAC/DC

pilz safety relay 750900 PNOS s pIE

pilz safety relay 750910 PNOS s nIE


pilz safety relay 750103 750104 usage requirements

1). Upon release of the emergency stop, the machine must not restart suddenly;

2). In the event of a failure in the machine safety circuit, the machine's power supply can be shut off;

3). When a safety circuit fails, the machine cannot be restarted;

4). Redundancy alone is insufficient. While redundancy is necessary, additional conditions are required, such as mutual monitoring of redundant circuits, verification that all safety circuits have been interrupted at least once, and the ability for an operator to initiate startup when necessary. Furthermore, from another perspective, measures must be taken to prevent unexpected machine startup caused by short circuits in input switch wiring or ground faults resulting from damaged cable insulation.

In practice, to facilitate the configuration of safety circuits, products that combine pilz safety relays 750103 750104 with other components into circuit modules for basic emergency stop and safety circuits are referred to as safety relay modules.



pilz safety relay 750103 750104 is composed of several relays and circuits to complement each other's abnormal defects, achieving correct and low false-operation relay functionality. This minimizes errors and failures, thereby increasing safety factors. Various safety relays are designed to protect machinery of different levels, with the main goal of protecting machine operators exposed to varying degrees of hazard. pilz safety relay 750103 750104 is used for inputs that confirm machine safety; after confirmation, it is applied in the design of safety circuits controlling inputs to contactors and other devices. Weidou Intelligent Technology supplies pilz safety relay 750103 750104 at special prices, with stock available in Shanghai.



Recommended products