Home/Products/ siemens circuit breaker, schneider relay, dold relay

dold current monitoring relay BA9053/010 original special price
dold current monitoring relay modules are used to accurately monitor changes in electrical quantities, such as signal faults and interference in current, voltage, power, and resistance. Therefore, these products can protect complex systems and ensure orderly production. The LED indicator on the front panel indicates the current system status. Output signals are output via relay contacts or transmitted via bus interfaces. dold current monitoring relays adjust the RMS value of the sinusoidal AC current of the equipment by calculating the arithmetic mean of the measured current values.
- SKU
- _P004442254
- Category
- siemens circuit breaker, schneider relay, dold relay
dold current monitoring relay BA9053/010 original import from Germany, good price, fast delivery.
dold current monitoring relay modules are used to accurately monitor changes in electrical quantities, such as signal faults and interference in current, voltage, power, and resistance. Therefore, these products can protect complex systems and ensure orderly production. The LED indicator on the front panel indicates the current system status. Output signals are output via relay contacts or transmitted via bus interfaces. dold current monitoring relays adjust the RMS value of the sinusoidal AC current of the equipment by calculating the arithmetic mean of the measured current values.
dold current monitoring relay BA 9053 advantages
Very wide current monitoring range, from 2 mA to 100 A, with compact installation space. Built-in current transformer, thereby saving installation costs such as wiring caused by external current transformers.System metal isolation: voltage drift/harmonics increase service life.
dold current monitoring relay BA 9053 applications
dold current monitoring relays are used to monitor current values in single-phase and three-phase systems, such as motors for pumps, cranes, elevators, fans, and emergency lighting systems.
dold current monitoring relay BA 9053 models
Model: BA9053/010 AC0,1-1AAC/DC24-80V, Item No.: 53120
Model: BA9053/010 AC0,1-1AAC/DC24-80V, Item No.: 54883
Model: BA9053/010 AC0,1-1AAC/DC80-230V, Item No.: 53121
Model: BA9053/010 AC0,1-1AAC/DC80-230V, Item No.: 53122
Model: BA9053/010 AC0,1-1AAC/DC80-230V, Item No.: 54494
Model: BA9053/010 AC0,1-1AAC/DC80-250V, Item No.: 63573
Model: BA9053/010 AC0,1-1AAC110V0-20S, Item No.: 53114
Model: BA9053/010 AC0,1-1AAC115V0-20S, Item No.: 53344
Model: BA9053/010 AC0,1-1AAC127V0-20S, Item No.: 53115
Model: BA9053/010 AC0,1-1AAC230V0-100S, Item No.: 64525
Model: BA9053/010 AC0,1-1AAC230V0-20S, Item No.: 53116
Model: BA9053/010 AC0,1-1AAC230V0-60S, Item No.: 53117
Model: BA9053/010 AC0,1-1AAC240V0-20S, Item No.: 53118
Model: BA9053/010 AC0,1-1AAC24V0-20S, Item No.: 53112
Model: BA9053/010 AC0,1-1AAC400V0-20S, Item No.: 53119
Model: BA9053/010 AC0, 1-1AAC42V0-20S, Item No.: 53113
Model: BA9053/010 AC0, 5-5AAC/DC24-80V, Item No.: 53133
Model: BA9053/010 AC0, 5-5AAC/DC24-80V, Item No.: 57300
Model: BA9053/010 AC0, 5-5AAC/DC24-80V, Item No.: 61719
Model: BA9053/010 AC0, 5-5AAC/DC80-230V, Item No.: 53134
Model: BA9053/010 AC0, 5-5AAC/DC80-230V, Item No.: 54493
Model: BA9053/010 AC0, 5-5AAC110V0-20S, Item No.: 53125
Model: BA9053/010 AC0, 5-5AAC115V0-20S, Item No.: 53126
Model: BA9053/010 AC0, 5-5AAC127V0-20S, Item No.: 53127
Model: BA9053/010 AC0, 5-5AAC230V0-100S, Item No.: 55316
Model: BA9053/010 AC0, 5-5AAC230V0-20S, Item No.: 53128
Model: BA9053/010 AC0, 5-5AAC230V0-30S, Item No.: 53129
Model: BA9053/010 AC0, 5-5AAC230V0-60S, Item No.: 53130
Model: BA9053/010 AC0, 5-5AAC240V0-20S, Item No.: 53131
Model: BA9053/010 AC0, 5-5AAC24V0-20S, Item No.: 53123
Model: BA9053/010 AC0, 5-5AAC400V0-20S, Item No.: 53132
Model: BA9053/010 AC0, 5-5AAC400V0-60S, Item No.: 61948
Model: BA9053/010 AC0, 5-5AAC42V0-20S, Item No.: 53124
Model: BA9053/010 AC0, 5-5AAC48V0-20S, Item No.: 53345
Model: BA9053/010 AC1, 5-15AAC/DC24-80V, Item No.: 54077
Model: BA9053/010 AC1, 5-15AAC/DC24-80V, Item No.: 63869
Model: BA9053/010 AC1, 5-15AAC/DC80-230V, Item No.: 57178
Model: BA9053/010 AC1, 5-15AAC230V0-100S, Item No.: 56951
Model: BA9053/010 AC1, 5-15AAC230V0-20S, Item No.: 53347
Model: BA9053/010 AC1, 5-15AAC24V0-20S, Item No.: 61732
Model: BA9053/010 AC10HZ1, 5-15AAC230V, Item No.: 54356
Model: BA9053/010 AC10HZ1-10AAC230V, Item No.: 56731
Model: BA9053/010 AC1-10AAC/DC24-80V, Item No.: 53142
Model: BA9053/010 AC1-10AAC/DC24-80V, Item No.: 53438
Model: BA9053/010 AC1-10AAC/DC80-230V, Item No.: 54190
Model: BA9053/010 AC1-10AAC/DC80-230V, Item No.: 54492
Model: BA9053/010 AC1-10AAC/DC80-230V, Item No.: 54976
Model: BA9053/010 AC1-10AAC110V0-20S, Item No.: 53137
Model: BA9053/010 AC1-10AAC115V0-20S, Item No.: 53767
Model: BA9053/010 AC1-10AAC127V0-20S, Item No.: 53346
Model: BA9053/010 AC1-10AAC230V0-100S, Item No.: 64052
Model: BA9053/010 AC1-10AAC230V0-20S, Item No.: 53138
Model: BA9053/010 AC1-10AAC230V0-30S, Item No.: 53139
Model: BA9053/010 AC1-10AAC230V0-60S, Item No.: 57325
Model: BA9053/010 AC1-10AAC240V0-20S, Item No.: 53140
Model: BA9053/010 AC1-10AAC24V0-20S, Item No.: 53135
Model: BA9053/010 AC1-10AAC400V0-20S, Item No.: 53141
Model: BA9053/010 AC1-10AAC42V0-20S, Item No.: 53136
Model: BA9053/010 AC1-10ADC12V0-20S, Item No.: 60968
Model: BA9053/010 AC162/3HZ0, 1-1A, Item No.: 61475
Model: BA9053/010 AC162/3HZ0, 1-1AAC230V, Item No.: 54716
Model: BA9053/010 AC162/3HZ0, 5-5A, Item No.: 55754
Model: BA9053/010 AC162/3HZ0, 5-5A, Item No.: 61476
Model: BA9053/010 AC162/3HZ0, 5-5AAC230V, Item No.: 54370
Model: BA9053/010 AC162/3HZ1-10A, Item No.: 63048
Model: BA9053/010 AC162/3HZ1-10A, Item No.: 63049
Model: BA9053/010 AC162/3HZ1-10AAC230V, Item No.: 54553
Model: BA9053/010 AC162/3HZ2-20AAC230V, Item No.: 54573
Model: BA9053/010 AC2, 5-25AAC/DC24-80V, Item No.: 53349
Model: BA9053/010 AC2, 5-25AAC/DC80-230V, Item No.: 54932
Model: BA9053/010 AC2, 5-25AAC110V0-20S, Item No.: 62636
Model: BA9053/010 AC2, 5-25AAC230V0-20S, Item No.: 53350
Model: BA9053/010 AC2, 5-25AAC400V0-20S, Item No.: 53351
Model: BA9053/010 AC20-200mAAC/DC24-80V, Item No.: 53105
Model: BA9053/010 AC20-200mAAC/DC80-230V, Item No.: 53106
Model: BA9053/010 AC20-200mAAC110V0-20S, Item No.: 53102
Model: BA9053/010 AC20-200mAAC115V0-20S, Item No.: 53335
Model: BA9053/010 AC20-200mAAC230V0-20S, Item No.: 53103
Model: BA9053/010 AC20-200mAAC240V0-20S, Item No.: 53104
Model: BA9053/010 AC20-200mAAC24V0-20S, Item No.: 53334
Model: BA9053/010 AC20-200mAAC42V0-20S, Item No.: 53355
Model: BA9053/010 AC2-20AAC/DC24-80V, Item No.: 54721
Model: BA9053/010 AC2-20AAC/DC80-230V, Item No.: 59110
Model: BA9053/010 AC2-20AAC230V0-20S, Item No.: 53348
Model: BA9053/010 AC2-20AAC230V0-30S, Item No.: 55640
Model: BA9053/010 AC2-20AAC24VTv=0-20S, Item No.: 53771
Model: BA9053/010 AC2-20mAAC/DC24-80V, Item No.: 53332
Model: BA9053/010 AC2-20mAAC/DC24-80V, Item No.: 53365
Model: BA9053/010 AC2-20mAAC/DC80-230V, Item No.: 53333
Model: BA9053/010 AC2-20mAAC110V0-20S, Item No.: 53330
Model: BA9053/010 AC2-20mAAC115V0-20S, Item No.: 53352
Model: BA9053/010 AC2-20mAAC127V0-20S, Item No.: 53353
Model: BA9053/010 AC2-20mAAC230V0-20S, Item No.: 53101
Model: BA9053/010 AC2-20mAAC240V0-20S, Item No.: 53331
Model: BA9053/010 AC2-20mAAC240V0-30S, Item No.: 53354
Model: BA9053/010 AC2-20mAAC24V0-20S, Item No.: 53100
Model: BA9053/010 AC2-20mAAC24V0-30S, Item No.: 53364
Model: BA9053/010 AC30-300mAAC/DC24-80V, Item No.: 55753
Model: BA9053/010 AC30-300mAAC/DC80-230V, Item No.: 53109
Model: BA9053/010 AC30-300mAAC110V0-20S, Item No.: 53107
Model: BA9053/010 AC30-300mAAC115V0-20S, Item No.: 53337
Model: BA9053/010 AC30-300mAAC127V0-20S, Item No.: 53338
Model: BA9053/010 AC30-300mAAC230V0-20S, Item No.: 53108
Model: BA9053/010 AC30-300mAAC240V0-20S, Item No.: 53339
Model: BA9053/010 AC30-300mAAC24V0-20S, Item No.: 53336
Model: BA9053/010 AC50-500mAAC/DC24-80V, Item No.: 53343
Model: BA9053/010 AC50-500mAAC/DC80-230V, Item No.: 55464
Model: BA9053/010 AC50-500mAAC110V0-20S, Item No.: 53341
Model: BA9053/010 AC50-500mAAC127V0-20S, Item No.: 53342
Model: BA9053/010 AC50-500mAAC230V0-20S, Item No.: 53110
Model: BA9053/010 AC50-500mAAC240V0-20S, Item No.: 53111
Model: BA9053/010 AC50-500mAAC24V0-20S, Part No.: 53356
Model: BA9053/010 AC50-500mAAC48V0-20S, Part No.: 53340
Model: BA9053/010 AC80-800mAAC/DC24-80V, Part No.: 55914
Model: BA9053/010 AC80-800mAAC/DC80-230V, Part No.: 64737
Model: BA9053/010 AC80-800mAAC230V0-20S, Part No.: 53357
Model: BA9053/010 DC1,35-13,5AAC110V, Part No.: 60551
Model: BA9053/010 /070AC0,1-1AAC110V, Part No.: 55813
Model: BA9053/010 /61AC0,1-1AUHAC120V5S, Part No.: 54544
Model: BA9053/010 /61AC0,5-5AUHAC120V5S, Part No.: 54543
Model: BA9053/010 /61AC1-10AUHAC120V5S, Part No.: 61942
dold current monitoring relay operation and maintenance
1. Before using the relay, remove the housing and extract the mechanism. Check for any damage incurred during transportation, such as the moving vane touching the magnetic plate, contact between turns of the hairspring, or friction on the moving vane shaft. To do this, set the relay pointer to the first setting point. Manually rotate the moving system toward the magnetic plate, then release it. The moving system should return to its original position until it hits the stop. Then perform necessary adjustments and settings.
2. When readjusting the relay, ensure the following:
2.1 The axial play of the moving system is between 0.15 and 0.3mm.
2.2 The air gap between the moving vane and the magnetic poles must ensure that the moving vane and magnetic plate do not touch under any specified operating conditions.
2.3 For relays with normally open and normally closed contacts, the bridge contact must not simultaneously contact one normally open static contact and one normally closed static contact.
2.4 When the pointer rotates from the first scale value to the final scale value, the turns of the hairspring must not touch each other.
2.5 When the relay operates, the bridge contact should slide along the center line of the static contact (tolerance ±lmm), and the total air gap between the moving and static contacts must be no less than 2mm.
2.6 The distance between the static contact and the limit piece should be no greater than 0.3mm.
2.7 When adjusting the relay operating value, adjustment of the minimum setting mainly involves changing the magnitude of the hairspring's counteracting force, while adjustment of the maximum setting mainly involves changing the air gap between the moving vane and the magnetic plate, etc.
2.8 Lubrication of the relay shaft and bearings is not recommended.
2.9 Do not use sandpaper or other abrasive materials to clean contacts. It is advisable to clean contacts with a sharp blade or a clean fine grinding stone, then wipe them clean with a clean, soft cloth. Avoid touching contacts with fingers.
Recommended products
European Import Purchasing Service - Including Niche Brand Procurement
MZT8-03VPS-KRX sensor MZT8-03VPS-KRX in stock MZT8-03VPS-KRX inventory
Orgatex floor marking solutions
caleffi automatic air vent
schwingmetall rubber vibration damper, type C, model 25329/C. German schwingmetall metal buffer. schwingmetall in stock.