IDEM Safety safety switch

IDEM Safety safety switch
IDEM SafetyHeavy-duty safety switchHYGIECODEmember of the series of switches,SMC-Ffeaturing a coded magnetic actuator and **14mmswitching tolerance.
IDEM SafetyThe safety switch is rated for105C SMC-Fdesign operating temperature up to125C。
IDEM Safetysafety switchSMC-Fcan be used with most safety relays to achievePLe / Cat4 ISO13849-1。
IDEM SafetyThe safety switch features a robust stainless steel316mirror-polished surface (Ra4) housing designed for food processing applications.
IDEM SafetyThe safety switch is suitable forCIP SIPclean- mounting holes located at the rear- thus avoiding food traps.
IDEM SafetyThe safety switch has a universal housing - 22mm fixed hole centers- 50mm wide body.
IDEM SafetyThe safety switch is rear-mounted2xM4threaded holes.
IDEM SafetyImportant note regarding the safety switch:
Please read and understand these instructions before installing, operating, or maintaining this device.
This product is designed as a component of a custom safety-oriented control system. Each manufacturer is responsible for ensuring the correct overall functionality of the system and machine. IDEM and its subsidiaries and affiliates cannot guaranteeIDEMall characteristics of the specific system or product design.
IDEM SafetySafety switch applications:
Coded non-contact switches are designed for interlocking hinged, sliding, or removable guard doors. They are particularly advantageous in the following cases:
a) where poor guard alignment exists
b) where tamper resistance is required
c) where high hygiene requirements exist, such as hose-down in the food industry
d) where long mechanical life is required (no moving or contacting parts).
IDEM SafetyWhen used with dual-channel safety relays, coded non-contact switches can provide up to4category andPleup toISO13849-1level of protection.
IDEM SafetySafety switch operation:
All coded non-contact safety switches are designed in accordance with the IEC 60947-5-3 standard and can be used in accordance withEN1088,EN ISO12100andEN 60204-1requirements. They use magnetic coding, which provides a wide (> 10mm) sensing distance and offers high tolerance to misalignment after sensing. They can be mounted behind stainless steel fittings, allowing operation in
extreme temperature and humidity environments.
IDEM SafetySafety switch installation:
Installation of all coded non-contact switches must comply with the risk assessment for the individual application.
Monitoring coded switches requires the use of safety relays. These relays monitor according to ISO13849-12redundant circuits, **up toPle / 4category protection. Coded non-contact switches are designed for use with most dual-channel safety relays to meetIEC 60947-5-3 PDF-Srequirements.
M4 mounting bolts must be used to secure the switch. (ExceptRPCandRMCtypes)RPCandRMCtypes require through-hole mounting via30.5mm. The provided lock nuts must be used to protect the switch. The tightening torque of the mounting bolts ensures reliable fixation at1.0 Nm. Always install on non-ferrous metal materials. The recommended setting gap is5mm. Safety switches must not be used as mechanical brakes, nor should they be struck with a hammer. Actuator impact on the switch is prohibited. Do not install adjacent switches
or actuators closer than 30mm. The typical misalignment error after setting is5mm. After installation, always check the function of each switch by opening and closing each guard individually, and ensure that the greenLEDon the switch and theLEDon the safety device illuminate the relay when the switch is closed and extinguish when the switch is open. Check that the machine stops and cannot restart when any switch is open. ForMPCtypes, install the protective screw covers after completing the final inspection.
IDEM SafetySafety Switch Maintenance:
Monthly: Check actuator alignment and inspect the switch housing for signs of mechanical damage. Inspect wiring for signs of damage.
Check the function of each switch by opening and closing each guard sequentially, and ensure that the green LED on the switch and the correspondingLEDon the safety relay illuminate when the switch is closed and extinguish when the switch is open. Check that the machine stops and cannot restart when any switch is open. Never repair any switch, actuator, or entire cable. Replace any switch showing signs of mechanical damage to the housing or cable.
IDEM SafetySafety Switch Safety Classification and Reliability Data:
Switching Reliability
EN 954-1
ISO 13849-1
EN 62061
Safety Data - Annual UsagePFHdProof Test Interval (Lifetime)MTTFdValue
IDEM SafetySafety Switch Standards:
Under 100mA load3.3×106Operation category with safety relay4UntilPLeDepends on system architecture depends on system architecture, ** isSIL3per hour8cycles/per day24hours/ 365days2.52×10-8
EN1088 IEC 60947-5-3 EN 60204-1
ISO 13849-1 EN62061 UL508
*Minimum switching current 10V. DC1mA
Dielectric strength 250V.ac
Insulation resistance 100 Mohms
Recommended setting gap 5mm
Switching distance
Sao 10mm OFF (RMC 8mmOFF)
Sar 20mm ON (RMC 12mmON)
Permissible deviation from the 5mm setting gap in any direction5mm
Switching frequency **1.0 Hz
Approach speed 200mm / m. To1000mm / s。
Housing material MPC SPC WMC LPC CPC RPC polyester
MMC SMC WMC LMC CMC RMC S / steel316
Temperature range -25 / 80C polyester-25 / 105C S /steel316
Protection rating IP67 (plastic)IP69K(stainless steel316)
Shock resistance IEC 68-2-27 11ms 30g
Vibration resistance IEC 68-2-6 10-55 Hz.1mm
Cable type PVC 6 or8core6mm O.D.
Mounting bolts 2 x M4 tightening torque1.0 Nm
Mounting position any
Our company's advantageous supplyIDEMSafety switches,IDEMSafety relays,IDEMPull cord switches,IDEMInterlock switches,IDEMSafety modules,IDEMEmergency stop switches,IDEMFast quotation,IDEMOriginal imported
Weidou Intelligent Technology (Shanghai) Co., Ltd.
Weidu Intelligent Technology (Shanghai) Co., Ltd
Add:No. 2601, Xietu Road, Xuhui District, Shanghai, China
Contact: Candy
Mobile: 0086 173 0212 6825
Tel:0086 021-50610211
QQ:204 666 9799
Email:candy@wdutech.com
Web:www. wdutech.com